FCC ID W6UNHR700LFN
ALLIANCE_N20
by SOLiD, Inc.
Grantee Code: W6U Product Code: NHR700LFN
Latest application date: 2018-02-09
FCC ID Device Details
| FCC ID | W6UNHR700LFN |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | W6U |
| Product Code | NHR700LFN |
| Applicant Business | SOLiD, Inc. 🇰🇷 |
| Related Domains | |
| Equipment Class | ALLIANCE_N20 |
| Test Firm | HCT Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 758-768 MHz | Original Equipment | 2018-02-09 |
| 728-758 MHz | Original Equipment | 2018-02-09 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| N20-R-HRDU-700LTE-FN User Manual_180115_rev.3 | Users Manual | 2018-08-08 | PDF 4.6 MB |
| N20-R-HRDU-700LTE-FN Internal Photos Metadata only | Internal Photos | 2018-08-08 | PDF 1.1 MB |
| N20-R-HRDU-700LTE-FN Internal Photos_Rev01 | Internal Photos | 2018-08-08 | PDF 1.5 MB |
| N20-R-HRDU-700LTE-FN External Photos | External Photos | 2018-08-08 | PDF 418.5 KB |
| N20-R-HRDU-700LTE-FN Label location_171013 | ID Label/Location Info | 2018-02-09 | PDF 382.9 KB |
| N20-R-HRDU-700LTE-FN Test Setup Photo | Test Setup Photos | 2018-08-08 | PDF 292.8 KB |
| N20-R-HRDU-700LTE-FN Test Report_for FCC_rev01_Part 1 | Test Report | 2018-02-09 | PDF 4.2 MB |
| N20-R-HRDU-700LTE-FN Test Report_for FCC_rev01_Part 2 | Test Report | 2018-02-09 | PDF 4.7 MB |
| W6UNHR700LFN_Attestation letter for Warning Label Message_Part20 | Cover Letter(s) | 2018-02-09 | PDF 48.2 KB |
| W6UNHR700LFN_Attestation letter for Warning Label Message_Part90 | Cover Letter(s) | 2018-02-09 | PDF 42.6 KB |
| W6UNHR700LFN_Agent Authorization Letter | Cover Letter(s) | 2018-02-09 | PDF 149.1 KB |
| W6UNHR700LFN_Confidentiality Request Letter | Cover Letter(s) | 2018-02-09 | PDF 102.7 KB |
| N20-R-HRDU-700LTE-FN Block Diagram_rev.1 Metadata only | Block Diagram | PDF 224.7 KB | |
| N20-R-HRDU-700LTE-FN Circuit Diagram_rev.1 Metadata only | Schematics | PDF 2.5 MB | |
| N20-R-HRDU-700LTE-FN Operational description_01232018_rev.1 Metadata only | Operational Description | PDF 658.8 KB | |
| N20-R-HRDU-700LTE-FN Part list Metadata only | Parts List/Tune Up Info | PDF 101.3 KB | |
| N20-R-HRDU-700LTE-FN Tune-up procedure_180115 Metadata only | Parts List/Tune Up Info | PDF 525 KB |
Application Information
| Application ID | ozuyhdwro13iUsTM8P14Bg== |
|---|---|
| Final Action Date | 2018-02-09 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018550988 |
| Model | NHR700LFN |
| Frequency Range | 758-768 MHz |
| Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) |
| Device Description | ALLIANCE_N20 |
| Responsible Party | Yong Chul Kim, Team Manager, yckim@solid.co.kr |
| Test Firm | Lee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr |
| TCB Email | tcb@hctamerica.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 08/08/2018 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | In-Building DAS Booster. Power output listed is conducted. Device supports LTE 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of §1.1307(b)(3), for satisfying RF exposure compliance. Class B Booster is fix location installation only according to §90.219(d)(4) and it is limited to deployed only up to 5 Watt maximum ERP requirement of §90.219(d)(3). RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ozuyhdwro13iUsTM8P14Bg== | 2018-02-09 | Original Equipment |
| bHJfO8R4ruMgfTt+IezZrw== | 2018-02-09 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application ozuyhdwro13iUsTM8P14Bg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 02/09/2018 Application Dated: 02/07/2018 |
| SOLiD, Inc. |
| 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, |
| Bundang-gu, |
| Seongnam-si, Gyeonggi-do, 463-400 South Korea |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UNHR700LFN |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | ALLIANCE_N20 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC PF | 90 | 758.0 - 768.0 | 19.679 | Amp | G7W |
| In-Building DAS Booster. Power output listed is conducted. Device supports LTE 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of §1.1307(b)(3), for satisfying RF exposure compliance. Class B Booster is fix location installation only according to §90.219(d)(4) and it is limited to deployed only up to 5 Watt maximum ERP requirement of §90.219(d)(3). RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| PF: | Transmitter approved for Public Safety Broadband |
EAS Grant - Application ozuyhdwro13iUsTM8P14Bg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SOLiD, Inc. 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400 South Korea |
Date of Grant: 02/09/2018 Application Dated: 02/07/2018 |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UNHR700LFN |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | ALLIANCE_N20 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC PF | 90 | 758.0 - 768.0 | 19.679 | Amp | G7W |
| In-Building DAS Booster. Power output listed is conducted. Device supports LTE 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of §1.1307(b)(3), for satisfying RF exposure compliance. Class B Booster is fix location installation only according to §90.219(d)(4) and it is limited to deployed only up to 5 Watt maximum ERP requirement of §90.219(d)(3). RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| PF: | Transmitter approved for Public Safety Broadband |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 02/09/2018 Application Dated: 02/07/2018 |
| SOLiD, Inc. |
| 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, |
| Bundang-gu, |
| Seongnam-si, Gyeonggi-do, 463-400 South Korea |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UNHR700LFN |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ALLIANCE_N20 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 27 | 728.0 - 758.0 | 19.724 | Amp | G7W |
| CC | 27 | 728.0 - 758.0 | 19.907 | Amp | G7W |
| In-Building DAS Booster. Output power is conducted. Device supports LTE 5 MHz and 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application bHJfO8R4ruMgfTt+IezZrw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SOLiD, Inc. 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400 South Korea |
Date of Grant: 02/09/2018 Application Dated: 02/07/2018 |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UNHR700LFN |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ALLIANCE_N20 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 27 | 728.0 - 758.0 | 19.724 | Amp | G7W |
| CC | 27 | 728.0 - 758.0 | 19.907 | Amp | G7W |
| In-Building DAS Booster. Output power is conducted. Device supports LTE 5 MHz and 10 MHz modulation. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna colocation requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |