FCC ID W6UNHR850IC
ALLIANCE_N20
by SOLiD, Inc.
Grantee Code: W6U Product Code: NHR850IC
Latest application date: 2018-02-09
FCC ID Device Details
| FCC ID | W6UNHR850IC |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | W6U |
| Product Code | NHR850IC |
| Applicant Business | SOLiD, Inc. 🇰🇷 |
| Related Domains | |
| Equipment Class | ALLIANCE_N20 |
| Test Firm | HCT Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 862-869 MHz | Original Equipment | 2018-02-09 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| N20-R-HRDU-850IC User Manual_180115_rev.3 | Users Manual | 2018-08-08 | PDF 4.2 MB |
| N20-R-HRDU-850IC Internal Photos Metadata only | Internal Photos | 2018-08-08 | PDF 1.3 MB |
| N20-R-HRDU-850IC Internal Photos_Rev01 | Internal Photos | 2018-08-08 | PDF 1.6 MB |
| N20-R-HRDU-850IC External Photos | External Photos | 2018-08-08 | PDF 333.6 KB |
| N20-R-HRDU-850IC Label location_171013 | ID Label/Location Info | 2018-02-09 | PDF 355.4 KB |
| N20-R-HRDU-850IC Test Setup Photo | Test Setup Photos | 2018-08-08 | PDF 297 KB |
| N20-R-HRDU-850IC Test Report_rev01_Part 1 | Test Report | 2018-02-09 | PDF 5.8 MB |
| N20-R-HRDU-850IC Test Report_rev01_Part 2 | Test Report | 2018-02-09 | PDF 5.1 MB |
| W6UNHR850IC_Attestation letter for Warning Label Message_Part20.pdf | Cover Letter(s) | 2018-02-09 | PDF 28.9 KB |
| W6UNHR850IC_Agent Authorization Letter.pdf | Cover Letter(s) | 2018-02-09 | PDF 45.6 KB |
| W6UNHR850IC_Confidentiality Request Letter.pdf | Cover Letter(s) | 2018-02-09 | PDF 52.2 KB |
| N20-R-HRDU-850IC Block Diagram Metadata only | Block Diagram | PDF 33.3 KB | |
| N20-R-HRDU-850IC Circuit Diagram_2018.1.26 Metadata only | Schematics | PDF 3.7 MB | |
| N20-R-HRDU-850IC Operational description_01232018_rev.1 Metadata only | Operational Description | PDF 658.8 KB | |
| N20-R-HRDU-850IC Tune-up procedure_180115 Metadata only | Parts List/Tune Up Info | PDF 525 KB | |
| N20-R-HRDU-850IC_Part list Metadata only | Parts List/Tune Up Info | PDF 173.9 KB |
Application Information
| Application ID | RDYXVhQ88anYvFGHXYaw4A== |
|---|---|
| Final Action Date | 2018-02-09 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018550988 |
| Model | NHR850IC |
| Frequency Range | 862-869 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | ALLIANCE_N20 |
| Responsible Party | Yong Chul Kim, Team Manager, yckim@solid.co.kr |
| Test Firm | Lee Yoon-Jung, HCT Co., Ltd., yjlee@hct.co.kr |
| TCB Email | tcb@hctamerica.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 08/08/2018 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | In-Building DAS Booster. Output power is conducted Devices supporting CDMA, WCDMA and LTE 5MHz and 10MHz will be the intended use. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| RDYXVhQ88anYvFGHXYaw4A== | 2018-02-09 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application RDYXVhQ88anYvFGHXYaw4A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
HCT America LLC 1726 Ringwood Avenue San Jose, CA 95131 |
Date of Grant: 02/09/2018 Application Dated: 02/07/2018 |
| SOLiD, Inc. |
| 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, |
| Bundang-gu, |
| Seongnam-si, Gyeonggi-do, 463-400 South Korea |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UNHR850IC |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ALLIANCE_N20 |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 869.0 - 894.0 | 20.512 | Amp | G7W | |
| 22H | 869.0 - 894.0 | 19.634 | Amp | F9W | |
| 90S | 862.0 - 869.0 | 19.999 | Amp | G7W | |
| 90S | 862.0 - 869.0 | 19.634 | Amp | F9W |
| In-Building DAS Booster. Output power is conducted Devices supporting CDMA, WCDMA and LTE 5MHz and 10MHz will be the intended use. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
EAS Grant - Application RDYXVhQ88anYvFGHXYaw4A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
SOLiD, Inc. 10,9th Floor, SOLiD Space, Pangyoyeok-ro 220, Bundang-gu, Seongnam-si, Gyeonggi-do, 463-400 South Korea |
Date of Grant: 02/09/2018 Application Dated: 02/07/2018 |
| Attention: Yong Chul Kim , Team Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | W6UNHR850IC |
| Name of Grantee: | SOLiD, Inc. |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ALLIANCE_N20 |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 869.0 - 894.0 | 20.512 | Amp | G7W | |
| 22H | 869.0 - 894.0 | 19.634 | Amp | F9W | |
| 90S | 862.0 - 869.0 | 19.999 | Amp | G7W | |
| 90S | 862.0 - 869.0 | 19.634 | Amp | F9W |
| In-Building DAS Booster. Output power is conducted Devices supporting CDMA, WCDMA and LTE 5MHz and 10MHz will be the intended use. This transmitter operates as a remote unit as part of a system along with base station interface unit as described in this filing, and excluding any other devices connected to the (uplink) transmit output terminal of the base station interface unit. This application covers only the system configuration with base interface unit connected to a base station RF port in the uplink transmit path; operations of this remote unit if any in a system with base interface unit connected to antenna or amplifier for uplink transmissions require separate equipment authorization. This device is authorized to operate only as part of a distributed-antenna booster system installed in buildings. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of Sec. 1.1307(b)(3), for satisfying RF exposure compliance. RF exposure will be addressed at time of installation and the use of higher gain antennas may require larger separation distances. |
| Mail To: |