FCC ID WMB-RM2-0001

Demand management/ Demand response wireless controller

by Regen Energy Inc

Grantee Code: WMB   Product Code: RM20001
Latest application date: 2008-09-16

FCC ID Device Details

FCC IDWMB-RM2-0001
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeWMB
Product CodeRM20001
Applicant BusinessRegen Energy Inc 🇨🇦
Related Domains regenenergy.com
Equipment ClassDemand management/ Demand response wireless controller
Test FirmGlobal EMC Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2400-2480 MHzOriginal Equipment2008-09-16

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2008-09-16PDF 501.2 KB
Internal PhotosInternal Photos2008-09-16PDF 714.4 KB
External PhotosExternal Photos2008-09-16PDF 746.2 KB
Label LocationID Label/Location Info2008-09-16PDF 162.3 KB
Label SampleID Label/Location Info2008-09-16PDF 162.3 KB
Operational DescriptionOperational Description2008-09-16PDF 214 KB
Test Setup PhotosTest Setup Photos2008-09-16PDF 467.7 KB
RF ExposureRF Exposure Info2008-09-16PDF 412.6 KB
Test ReportTest Report2008-09-16PDF 1.9 MB
Confidential LetterCover Letter(s)2008-09-16PDF 237.1 KB
Cover LetterCover Letter(s)2008-09-16PDF 186.6 KB
REL LetterCover Letter(s)2008-09-16PDF 216.6 KB

Application Information

Application ID5SB11IdUTv9RIowVh4EjLw==
Final Action Date2008-09-16
Application PurposeOriginal Equipment
Applicant FRN0018033654
Model-RM2-0001
Frequency Range2400-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionDemand management/ Demand response wireless controller
Responsible PartyRoman Kulyk, CTO, roman.kulyk@regenenergy.com , 416-934-1040
Test FirmScott Drysdale, Global EMC Inc., scott@globaladvantage.ca , 905-883-3919
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of &#167;2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device must limit its output power on its highest operating channel to <= 16.3 dBm in order to maintain compliance with 47 CFR Part 15 Subpart C paragraph 15.205.

Applications

Application IDDatePurpose
5SB11IdUTv9RIowVh4EjLw==2008-09-16Original Equipment

Equipment Authorization

FrequencyOutputRules
2400-2480 MHz0.077600015C

Grants

TCB Grant - Application 5SB11IdUTv9RIowVh4EjLw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 09/16/2008

Application Dated: 09/12/2008
Regen Energy Inc
15 Belfield Rd., Unit #5,
Toronto, M9W 1E8
Canada
 
Attention: Roman Kulyk , CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WMB-RM2-0001
Name of Grantee:  Regen Energy Inc
Equipment Class: Digital Transmission System
Notes: Demand management/ Demand response wireless controller
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2400.0  -  2480.0 0.0776  

Power listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device must limit its output power on its highest operating channel to <= 16.3 dBm in order to maintain compliance with 47 CFR Part 15 Subpart C paragraph 15.205.

EAS Grant - Application 5SB11IdUTv9RIowVh4EjLw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Regen Energy Inc
15 Belfield Rd., Unit #5, P.O. Box ,
Toronto, M9W 1E8
Canada
  Date of Grant: 09/16/2008

Application Dated: 09/12/2008
 
Attention: Roman Kulyk , CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WMB-RM2-0001
Name of Grantee:  Regen Energy Inc
Equipment Class: Digital Transmission System
Notes: Demand management/ Demand response wireless controller
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2400.0  -  2480.0 0.0776  

Power listed is conducted. The antenna installation and operating configurations of this transmitter, including any applicable antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device must limit its output power on its highest operating channel to