FCC ID WONBC24403000
PBC Beacon
by Precyse Technologies Inc
Grantee Code: WON Product Code: BC24403000
Latest application date: 2008-11-06
FCC ID Device Details
| FCC ID | WONBC24403000 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | WON |
| Product Code | BC24403000 |
| Applicant Business | Precyse Technologies Inc 🇮🇱 |
| Related Domains | |
| Equipment Class | PBC Beacon |
| Test Firm | Israel Testing Laboratories |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2410-2475 MHz | Original Equipment | 2008-11-06 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2008-11-06 | PDF 352.2 KB |
| Internal Photos | Internal Photos | 2008-11-06 | PDF 143.8 KB |
| External Photos | External Photos | 2008-11-06 | PDF 3.6 MB |
| Label Location | ID Label/Location Info | 2008-11-06 | PDF 83.5 KB |
| Label Sample | ID Label/Location Info | 2008-11-06 | PDF 24.3 KB |
| Operational Description | Operational Description | 2008-11-06 | PDF 313.2 KB |
| Test Setup Photos | Test Setup Photos | 2008-11-06 | PDF 969.1 KB |
| Test Report | Test Report | 2008-11-06 | PDF 349.3 KB |
| Confidential Letter | Cover Letter(s) | 2008-11-06 | PDF 170.6 KB |
| RF Exposure | RF Exposure Info | 2008-11-06 | PDF 18.7 KB |
Application Information
| Application ID | HZm2exRasbAq1S6aq/X/Dg== |
|---|---|
| Final Action Date | 2008-11-06 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018086421 |
| Model | BC24403000 |
| Frequency Range | 2410-2475 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | PBC Beacon |
| Responsible Party | Yossi Nurok, Hardware Engineer, ynurok@precysetech.com |
| Test Firm | IIan Cohen, Israel Testing Laboratories, sraz@itl.co.il |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is Conducted single carrier operation. This device must be professionally installed. The antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter is restricted for use with the specific antenna(s) tested in this application for Certification. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| HZm2exRasbAq1S6aq/X/Dg== | 2008-11-06 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2410-2475 MHz | 0.2000000 | 15C |
Grants
TCB Grant - Application HZm2exRasbAq1S6aq/X/Dg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 |
Date of Grant: 11/06/2008 Application Dated: 11/06/2008 |
| Precyse Technologies Inc |
| Ha'amal 11 |
| Haamal 11 Rosh Haayin |
| Rosh Ha'ayin, 48092 Israel |
| Attention: Yossi Nurok , Hardware Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | WONBC24403000 |
| Name of Grantee: | Precyse Technologies Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | PBC Beacon |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2410.0 - 2475.0 | 0.2 |
| Power listed is Conducted single carrier operation. This device must be professionally installed. The antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter is restricted for use with the specific antenna(s) tested in this application for Certification. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application HZm2exRasbAq1S6aq/X/Dg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Precyse Technologies Inc Ha'amal 11 Haamal 11 Rosh Haayin Rosh Ha'ayin, 48092 Israel |
Date of Grant: 11/06/2008 Application Dated: 11/06/2008 |
| Attention: Yossi Nurok , Hardware Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | WONBC24403000 |
| Name of Grantee: | Precyse Technologies Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | PBC Beacon |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2410.0 - 2475.0 | 0.2 |
| Power listed is Conducted single carrier operation. This device must be professionally installed. The antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. This transmitter is restricted for use with the specific antenna(s) tested in this application for Certification. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |