FCC ID WP3GB501PG2
Wireless glassbreak detector
by Visonic Ltd.
Grantee Code: WP3 Product Code: GB501PG2
Latest application date: 2011-12-16
FCC ID Device Details
| FCC ID | WP3GB501PG2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | WP3 |
| Product Code | GB501PG2 |
| Applicant Business | Visonic Ltd. 🇮🇱 |
| Related Domains | |
| Equipment Class | Wireless glassbreak detector |
| Test Firm | Hermon Laboratories Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 912.75-919.106 MHz | Original Equipment | 2011-12-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| manual | Users Manual | 2011-12-16 | PDF 326.5 KB |
| int photo | Internal Photos | 2011-12-16 | PDF 127 KB |
| ext photo | External Photos | 2011-12-16 | PDF 34 KB |
| label info | ID Label/Location Info | 2011-12-16 | PDF 34.3 KB |
| tsup photo | Test Setup Photos | 2011-12-16 | PDF 391.3 KB |
| Test report 15247 FHSS | Test Report | 2011-12-16 | PDF 1.1 MB |
| conf req | Cover Letter(s) | 2011-12-16 | PDF 18.4 KB |
| poa | Cover Letter(s) | 2011-12-16 | PDF 29.1 KB |
| RF exp calc | RF Exposure Info | 2011-12-16 | PDF 12.6 KB |
Application Information
| Application ID | 0QibWIO2RRl3wyEM0oNbUw== |
|---|---|
| Final Action Date | 2011-12-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018112599 |
| Model | GB501PG2 |
| Frequency Range | 912.75-919.106 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Wireless glassbreak detector |
| Responsible Party | Arick Elshtein, International Standards Department Manager, aelshtein@visonic.com |
| Technical Contact | Michael Nikishin, Hermon Laboratories Ltd, nikishin@hermonlabs.com |
| Test Firm | Alexander Usoskin, Hermon Laboratories Ltd., mail@hermonlabs.com |
| TCB Email | certification@telefication.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. The device with its internal antenna must be installed to provide a separation distance of at least 20 cm from all persons. No co-location or operation in conjunction with any other antenna or transmitter permitted. End-users must be provided with operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 0QibWIO2RRl3wyEM0oNbUw== | 2011-12-16 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 912.75-919.106 MHz | 0.3660000 | 15C |
Grants
TCB Grant - Application 0QibWIO2RRl3wyEM0oNbUw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Telefication B.V. Edisonstraat 12a Zevenaar, NL-6902 PK Netherlands |
Date of Grant: 12/16/2011 Application Dated: 12/12/2011 |
| Visonic Ltd. |
| 24 Habarzel street |
| Tel Aviv, 61920 Israel |
| Attention: Arick Elshtein , International Standards Department Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | WP3GB501PG2 |
| Name of Grantee: | Visonic Ltd. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Wireless glassbreak detector |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 912.75 - 919.106 | 0.366 |
| Power output listed is conducted. The device with its internal antenna must be installed to provide a separation distance of at least 20 cm from all persons. No co-location or operation in conjunction with any other antenna or transmitter permitted. End-users must be provided with operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application 0QibWIO2RRl3wyEM0oNbUw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Visonic Ltd. 24 Habarzel street P.O. Box , Tel Aviv, 61920 Israel |
Date of Grant: 12/16/2011 Application Dated: 12/12/2011 |
| Attention: Arick Elshtein , International Standards Department Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | WP3GB501PG2 |
| Name of Grantee: | Visonic Ltd. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Wireless glassbreak detector |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 912.75 - 919.106 | 0.366 |
| Power output listed is conducted. The device with its internal antenna must be installed to provide a separation distance of at least 20 cm from all persons. No co-location or operation in conjunction with any other antenna or transmitter permitted. End-users must be provided with operating conditions for satisfying RF exposure compliance. |
| Mail To: |