FCC ID WP3MP843

PIR detector ZigBee

by Visonic Ltd.

Grantee Code: WP3   Product Code: MP843
Latest application date: 2020-07-01

FCC ID Device Details

FCC IDWP3MP843
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeWP3
Product CodeMP843
Applicant BusinessVisonic Ltd. 🇮🇱
Related Domains tycoint.com jci.com
Equipment ClassPIR detector ZigBee
Test FirmHermon Laboratories Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405-2480 MHzOriginal Equipment2020-07-01

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2020-07-01PDF 611 KB
Internal PhotosInternal Photos2020-12-17PDF 173.7 KB
External PhotosExternal Photos2020-07-01PDF 60.2 KB
ID Label/Location InfoID Label/Location Info2020-07-01PDF 95.9 KB
Test Setup PhotosTest Setup Photos2020-07-01PDF 445 KB
Test Report-1Test Report2020-07-01PDF 2.7 MB
Test Report-2Test Report2020-07-01PDF 2.9 MB
Test Report-3Test Report2020-07-01PDF 2.9 MB
Test Report-4Test Report2020-07-01PDF 2.3 MB
Cover_letterCover Letter(s)2020-07-01PDF 216.8 KB
Declaration_of_authorizationCover Letter(s)2020-07-01PDF 398.4 KB
Request for confidentialityCover Letter(s)2020-07-01PDF 121.1 KB
RF Exposure InfoRF Exposure Info2020-07-01PDF 20.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 229.1 KB
Schematics Metadata onlySchematicsPDF 794.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 495.7 KB

Application Information

Application IDLshWGSghS5IqwYFIiMexXA==
Final Action Date2020-07-01
Application PurposeOriginal Equipment
Applicant FRN0018112599
ModelMP843
Frequency Range2405-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionPIR detector ZigBee
Responsible PartyZuri Rubin, Certification Manager, zurir@tycoint.com , +97236456832
Technical ContactMichael Nikishin, Hermon Laboratories Ltd., nikishin@hermonlabs.com , 972 4626 8440
Non-Technical ContactZuri Rubin, Visonic Ltd., zuri.rubin@jci.com , 972 3645 6832
Test FirmGeorge Shleimovich, Hermon Laboratories Ltd., George@HERMONLABS.com , 97246268468
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date12/17/2020
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
LshWGSghS5IqwYFIiMexXA==2020-07-01Original Equipment

Equipment Authorization

FrequencyOutputRules
2405-2480 MHz0.083000015C

Grants

TCB Grant - Application LshWGSghS5IqwYFIiMexXA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 07/01/2020

Application Dated: 06/19/2020
Visonic Ltd.
24 Habarzel street
Tel Aviv, 61920
Israel
 
Attention: Zuri Rubin , Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WP3MP843
Name of Grantee:  Visonic Ltd.
Equipment Class: Digital Transmission System
Notes: PIR detector ZigBee
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0 0.083  

Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application LshWGSghS5IqwYFIiMexXA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Visonic Ltd.
24 Habarzel street
Tel Aviv, 61920
Israel
  Date of Grant: 07/01/2020

Application Dated: 06/19/2020
 
Attention: Zuri Rubin , Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WP3MP843
Name of Grantee:  Visonic Ltd.
Equipment Class: Digital Transmission System
Notes: PIR detector ZigBee
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0 0.083  

Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: