FCC ID WQ8-DV2531

ADVANCED AUTOMOTIVE DIAGNOSTICS ANALYZER

by Autel Intelligent Technology Corp., Ltd.

Grantee Code: WQ8   Product Code: DV2531
Latest application date: 2025-08-26

FCC ID Device Details

FCC IDWQ8-DV2531
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeWQ8
Product CodeDV2531
Applicant BusinessAutel Intelligent Technology Corp., Ltd. 🇨🇳
Related Domains autel.com
Equipment ClassADVANCED AUTOMOTIVE DIAGNOSTICS ANALYZER
Test FirmShenzhen EU Testing Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2025-08-26
5180-5240 MHzOriginal Equipment2025-08-26
2412-2462 MHzOriginal Equipment2025-08-26

Exhibits

DocumentTypeAvailableFile
User manual D1 Max2Users Manual2026-02-22PDF 2.4 MB
User manual D1 ProS2Users Manual2026-02-22PDF 1.6 MB
Internal photosInternal Photos2026-02-22PDF 3.7 MB
External photosExternal Photos2026-02-22PDF 705.9 KB
ID label and locationID Label/Location Info2025-08-26PDF 226.2 KB
Test Setup photoTest Setup Photos2026-02-22PDF 1 MB
Test Setup photo SARTest Setup Photos2026-02-22PDF 419.1 KB
Antenna Specification WifiTest Report2025-08-26PDF 1.4 MB
Test report BTTest Report2025-08-26PDF 1.7 MB
Test report BT DATATest Report2025-08-26PDF 4.6 MB
Test report WiFi 2.4GTest Report2025-08-26PDF 2.7 MB
Test report WiFi 2.4G DATATest Report2025-08-26PDF 4.5 MB
Test report WiFi 5GTest Report2025-08-26PDF 3 MB
Test report WiFi 5G DATATest Report2025-08-26PDF 3.5 MB
Attestation_StatementAttestation Statements2025-08-26PDF 158.9 KB
Kaspersky Software Security Requirements StatementAttestation Statements2025-08-26PDF 615 KB
Kaspersky StatementAttestation Statements2025-08-26PDF 305.9 KB
Product similarity DeclarationAttestation Statements2025-08-26PDF 117.3 KB
TCB_validation_US_agent_processAttestation Statements2025-08-26PDF 509.6 KB
Us_AgentAttestation Statements2025-08-26PDF 118.7 KB
ConfidentialityCover Letter(s)2025-08-26PDF 179.3 KB
Letter AuthorizationCover Letter(s)2025-08-26PDF 76.3 KB
Software ConfigurationCover Letter(s)2025-08-26PDF 73.7 KB
RF Exposure SARRF Exposure Info2025-08-26PDF 2.9 MB
Block Diagram Metadata onlyBlock DiagramPDF 541.2 KB
Schematics Metadata onlySchematicsPDF 1.2 MB
Schematics SC668S-WF Metadata onlySchematicsPDF 391.9 KB
Operational Description Metadata onlyOperational DescriptionPDF 129.4 KB
Software Security Metadata onlySDR Software/Security Info.PDF 106.8 KB

Application Information

Application IDJwVY9km6Uh0jR4Rnom9XoQ==
Final Action Date2025-08-26
Application PurposeOriginal Equipment
Applicant FRN0018132787
ModelDV2531
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionADVANCED AUTOMOTIVE DIAGNOSTICS ANALYZER
Responsible PartyFrank Li, President, sales@autel.com , (86)755-86147779
Technical ContactSally Zhang, Shenzhen EU Testing Laboratory Limited, sally.zhang@eu-test.com , (86)-18824580176
Test FirmSally Zhang, Shenzhen EU Testing Laboratory Limited, sally.zhang@eu-test.com , (86)-18824580176
TCB Emailelabscert@applus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date02/22/2026
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted.

Applications

Application IDDatePurpose
JwVY9km6Uh0jR4Rnom9XoQ==2025-08-26Original Equipment
JFQ1KGgoPG/npkbo50wBeQ==2025-08-26Original Equipment
EyauILrhkq0nXlUZpIypCQ==2025-08-26Original Equipment

Equipment Authorization

FrequencyOutputGrant Notes
2402-2480 MHz0.0016000CC
2412-2462 MHz0.0285000CC
5180-5240 MHz0.0225CC
5745-5825 MHz0.0274CC

Grants

TCB Grant - Application JwVY9km6Uh0jR4Rnom9XoQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 08/26/2025

Application Dated: 08/26/2025
Autel Intelligent Technology Corp., Ltd.
Floor 2, Caihong Keji Building, 36 Hi-tech North
Six Road, Songpingshan Community, Xili, Nanshan,
Shenzhen, 518055
China
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8-DV2531
Name of Grantee:  Autel Intelligent Technology Corp., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: ADVANCED AUTOMOTIVE DIAGNOSTICS ANALYZER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0016  

Output power listed is conducted.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application JFQ1KGgoPG/npkbo50wBeQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 08/26/2025

Application Dated: 08/26/2025
Autel Intelligent Technology Corp., Ltd.
Floor 2, Caihong Keji Building, 36 Hi-tech North
Six Road, Songpingshan Community, Xili, Nanshan,
Shenzhen, 518055
China
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8-DV2531
Name of Grantee:  Autel Intelligent Technology Corp., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: ADVANCED AUTOMOTIVE DIAGNOSTICS ANALYZER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0225  
CC 15E 5745.0  -  5825.0 0.0274  

Output power listed is conducted. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions are 0.61W/kg and 0.77 W/kg, respectively. The device contains 20MHz, 40MHz and 80MHz.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application EyauILrhkq0nXlUZpIypCQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  LGAI Technological Center S.A. (APPLUS)
Ronda de la Font del Carme, s/n <BR>P.O. Box 08193,
Barcelona,
Spain
Date of Grant: 08/26/2025

Application Dated: 08/26/2025
Autel Intelligent Technology Corp., Ltd.
Floor 2, Caihong Keji Building, 36 Hi-tech North
Six Road, Songpingshan Community, Xili, Nanshan,
Shenzhen, 518055
China
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8-DV2531
Name of Grantee:  Autel Intelligent Technology Corp., Ltd.
Equipment Class: Digital Transmission System
Notes: ADVANCED AUTOMOTIVE DIAGNOSTICS ANALYZER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0285  

Output power listed is conducted. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory and simultaneous transmission use conditions are 0.36W/kg and 0.53 W/kg, respectively. The device contains 20MHz and 40MHz.

CC: This device is certified pursuant to two different Part 15 rules sections.