FCC ID WQ8MAXISYSULTRA18

AUTOMOTIVE DIAGNOSTIC &ANALYSIS; SYSTEM

by Autel Intelligent Tech. Corp., Ltd.

Grantee Code: WQ8   Product Code: MAXISYSULTRA18
Latest application date: 2019-11-12

FCC ID Device Details

FCC IDWQ8MAXISYSULTRA18
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeWQ8
Product CodeMAXISYSULTRA18
Applicant BusinessAutel Intelligent Tech. Corp., Ltd. 🇨🇳
Related Domains autel.com
Equipment ClassAUTOMOTIVE DIAGNOSTIC &ANALYSIS; SYSTEM
Test FirmShenzhen Anbotek Compliance Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2019-11-12
5180-5240 MHzOriginal Equipment2019-11-12
2402-2480 MHzOriginal Equipment2019-11-11

Exhibits

DocumentTypeAvailableFile
15_MaxiSys Ultra UserMan-US r2Users Manual2019-11-12PDF 5.2 MB
09_MaxiSys Ultra IntPho r3Internal Photos2019-11-12PDF 1.1 MB
08_MaxiSys Ultra ExtPho r1External Photos2019-11-12PDF 834.9 KB
06_MaxiSys Ultra LabelSmpl-US r1ID Label/Location Info2019-11-12PDF 98 KB
17_MaxiSys Ultra AntSpec r3Operational Description2019-11-12PDF 85.1 KB
10_MaxiSys Ultra TSup r1Test Setup Photos2019-11-12PDF 547.8 KB
14_MaxiSys Ultra TestRpt DTS WiFi module 1 r2Test Report2019-11-12PDF 2.7 MB
14_MaxiSys Ultra TestRpt DTS WiFi module 2 r3Test Report2019-11-12PDF 4.3 MB
14_MaxiSys Ultra TestRpt NII 5.1G r2Test Report2019-11-12PDF 3.3 MB
14_MaxiSys Ultra TestRpt NII 5.8G r1Test Report2019-11-12PDF 3.2 MB
14_MaxiSys Ultra TestRpt DSS r2Test Report2019-11-11PDF 5.2 MB
18_MaxiSys Ultra RFExp r3RF Exposure Info2019-11-12PDF 5.1 MB
12_MaxiSys Ultra BlkDia r3 Metadata onlyBlock DiagramPDF 142.6 KB
13_MaxiSys Ultra Schem r2 Metadata onlySchematicsPDF 397.1 KB
11_MaxiSys Ultra OpDes r9 Metadata onlyOperational DescriptionPDF 60.8 KB
65_MaxiSys Ultra SW SecDecl Metadata onlySDR Software/Security InfPDF 683.4 KB

Application Information

Application IDDqLLuQ0rlfNEtCWp8U5y6Q==
Final Action Date2019-11-12
Application PurposeOriginal Equipment
Applicant FRN0018132787
ModelMAXISYSULTRA18
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionAUTOMOTIVE DIAGNOSTIC &ANALYSIS; SYSTEM
Responsible PartyFrank Li, President, sales@autel.com , (86)755-86147779
Test FirmJeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com , 86-755-26064492
TCB Emailjoergkusig@eurofins.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. This device supports 20MHz bandwidth operation only. SAR compliance is based on a separation distance of 0mm between the unit and the body of the user. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.531/kg and1.244W/kg respectively.

Applications

Application IDDatePurpose
DqLLuQ0rlfNEtCWp8U5y6Q==2019-11-12Original Equipment
7PbMAKkemIwtXz2g0iqiWw==2019-11-12Original Equipment
YAdsDwShi0L/SeHk9PWKow==2019-11-11Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2402-2480 MHz0.059800015CCC
2412-2462 MHz0.039500015CCC, MO
5180-5240 MHz0.095915ECC, MO
5745-5825 MHz0.023315ECC, MO

Grants

TCB Grant - Application YAdsDwShi0L/SeHk9PWKow==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 11/11/2019

Application Dated: 11/11/2019
Autel Intelligent Tech. Corp., Ltd.
7th-8th, 10th Floor, Bldg. B1, Zhiyuan,
Xueyuan Rd. Xili, Nanshan,
Shenzhen, 518055
China
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8MAXISYSULTRA18
Name of Grantee:  Autel Intelligent Tech. Corp., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AUTOMOTIVE DIAGNOSTIC & ANALYSIS SYSTEM
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0598  

Power listed is conducted. SAR compliance is based on a separation distance of 0 mm between the unit and the body of the user. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.531/kg and1.244W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application YAdsDwShi0L/SeHk9PWKow==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Autel Intelligent Tech. Corp., Ltd.
7th-8th, 10th Floor, Bldg. B1, Zhiyuan, Xueyuan Rd. Xili, Nanshan,
Shenzhen, 518055
China
  Date of Grant: 11/11/2019

Application Dated: 11/11/2019
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8MAXISYSULTRA18
Name of Grantee:  Autel Intelligent Tech. Corp., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: AUTOMOTIVE DIAGNOSTIC & ANALYSIS SYSTEM
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0598  

Power listed is conducted. SAR compliance is based on a separation distance of 0 mm between the unit and the body of the user. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.531/kg and1.244W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application DqLLuQ0rlfNEtCWp8U5y6Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 11/12/2019

Application Dated: 11/11/2019
Autel Intelligent Tech. Corp., Ltd.
7th-8th, 10th Floor, Bldg. B1, Zhiyuan,
Xueyuan Rd. Xili, Nanshan,
Shenzhen, 518055
China
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8MAXISYSULTRA18
Name of Grantee:  Autel Intelligent Tech. Corp., Ltd.
Equipment Class: Digital Transmission System
Notes: AUTOMOTIVE DIAGNOSTIC &ANALYSIS SYSTEM
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.0395  

Power listed is conducted. This device supports 20MHz bandwidth operation only. SAR compliance is based on a separation distance of 0mm between the unit and the body of the user. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.531/kg and1.244W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application DqLLuQ0rlfNEtCWp8U5y6Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Autel Intelligent Tech. Corp., Ltd.
7th-8th, 10th Floor, Bldg. B1, Zhiyuan, Xueyuan Rd. Xili, Nanshan,
Shenzhen, 518055
China
  Date of Grant: 11/12/2019

Application Dated: 11/11/2019
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8MAXISYSULTRA18
Name of Grantee:  Autel Intelligent Tech. Corp., Ltd.
Equipment Class: Digital Transmission System
Notes: AUTOMOTIVE DIAGNOSTIC &ANALYSIS SYSTEM
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.0395  

Power listed is conducted. This device supports 20MHz bandwidth operation only. SAR compliance is based on a separation distance of 0mm between the unit and the body of the user. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.531/kg and1.244W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 7PbMAKkemIwtXz2g0iqiWw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Product Service GmbH
Storkower Strasse 38c
D-15526 Reichenwalde,
Germany
Date of Grant: 11/12/2019

Application Dated: 11/11/2019
Autel Intelligent Tech. Corp., Ltd.
7th-8th, 10th Floor, Bldg. B1, Zhiyuan,
Xueyuan Rd. Xili, Nanshan,
Shenzhen, 518055
China
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8MAXISYSULTRA18
Name of Grantee:  Autel Intelligent Tech. Corp., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AUTOMOTIVE DIAGNOSTIC & ANALYSIS SYSTEM
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0959  
CC MO 15E 5745.0  -  5825.0 0.0233  

Power listed is conducted. This device supports 20MHz bandwidth operation only. SAR compliance is based on a separation distance of 0mm between the unit and the body of the user. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.531/kg and1.244W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 7PbMAKkemIwtXz2g0iqiWw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Autel Intelligent Tech. Corp., Ltd.
7th-8th, 10th Floor, Bldg. B1, Zhiyuan, Xueyuan Rd. Xili, Nanshan,
Shenzhen, 518055
China
  Date of Grant: 11/12/2019

Application Dated: 11/11/2019
 
Attention: Frank Li , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WQ8MAXISYSULTRA18
Name of Grantee:  Autel Intelligent Tech. Corp., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AUTOMOTIVE DIAGNOSTIC & ANALYSIS SYSTEM
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0959  
CC MO 15E 5745.0  -  5825.0 0.0233  

Power listed is conducted. This device supports 20MHz bandwidth operation only. SAR compliance is based on a separation distance of 0mm between the unit and the body of the user. Belt clips or holsters not listed in this filing may not contain metallic components. Highest reported SAR for Body-worn and simultaneous transmission is: 0.531/kg and1.244W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: