FCC ID WUR-FZ100

Foundation Smart Thermostat and Home Energy Gateway

by Energate Inc.

Grantee Code: WUR   Product Code: FZ100
Latest application date: 2012-07-17

FCC ID Device Details

FCC IDWUR-FZ100
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeWUR
Product CodeFZ100
Applicant BusinessEnergate Inc. 🇨🇦
Related Domains energateinc.com
Equipment ClassFoundation Smart Thermostat and Home Energy Gateway
Test FirmNemko Canada Inc

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405-2480 MHzOriginal Equipment2012-07-17

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2012-07-17PDF 1.9 MB
internal photosInternal Photos2012-07-17PDF 264.2 KB
external photosExternal Photos2012-07-17PDF 323.2 KB
labelID Label/Location Info2012-07-17PDF 246.9 KB
label locationID Label/Location Info2012-07-17PDF 1.2 MB
test setup photosTest Setup Photos2012-07-17PDF 444.4 KB
test reportTest Report2012-07-17PDF 2 MB
confidential letterCover Letter(s)2012-07-17PDF 183.4 KB
MPE calculationRF Exposure Info2012-07-17PDF 34.1 KB

Application Information

Application ID7fIAe9cjzdK+IvDsYwMBIg==
Final Action Date2012-07-17
Application PurposeOriginal Equipment
Applicant FRN0018227421
Model-FZ100
Frequency Range2405-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionFoundation Smart Thermostat and Home Energy Gateway
Responsible PartyJorge Deligiannis, CTO, JDeligiannis@energateinc.com , 613-482-7928
Technical ContactJorge Deligiannis, Energate Inc., JDeligiannis@energateinc.com , 613-482-7928
Non-Technical ContactDilip Waghray, Energate Inc., dwaghray@energateinc.com , 613-482-7928
Test FirmStuart Beck, Nemko Canada Inc, stuart.beck@nemko.com , 6137379680
TCB Emailstuart.beck@nemko.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput power is conducted. Output power is reduced at 2480 MHz as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons (excluding hands and wrists) and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
7fIAe9cjzdK+IvDsYwMBIg==2012-07-17Original Equipment

Equipment Authorization

FrequencyOutputRules
2405-2480 MHz0.100000015C

Grants

TCB Grant - Application 7fIAe9cjzdK+IvDsYwMBIg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko Canada Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 07/17/2012

Application Dated: 07/17/2012
Energate Inc.
2415 Holly Lane
Suite 210
Ottawa, K1V 7P1
Canada
 
Attention: Jorge Deligiannis , CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WUR-FZ100
Name of Grantee:  Energate Inc.
Equipment Class: Digital Transmission System
Notes: Foundation Smart Thermostat and Home Energy Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0 0.1  

Output power is conducted. Output power is reduced at 2480 MHz as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons (excluding hands and wrists) and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application 7fIAe9cjzdK+IvDsYwMBIg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Energate Inc.
2415 Holly Lane Suite 210P.O. Box ,
Ottawa, K1V 7P1
Canada
  Date of Grant: 07/17/2012

Application Dated: 07/17/2012
 
Attention: Jorge Deligiannis , CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WUR-FZ100
Name of Grantee:  Energate Inc.
Equipment Class: Digital Transmission System
Notes: Foundation Smart Thermostat and Home Energy Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0 0.1  

Output power is conducted. Output power is reduced at 2480 MHz as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons (excluding hands and wrists) and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: