FCC ID WX3-122
Accu-Check Instant
by Roche Diabetes Care
Grantee Code: WX3 Product Code: 122
Latest application date: 2017-06-01
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2017-06-01 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| UserManual.pdf | Users Manual | 2017-06-30 | PDF 2.4 MB |
| InternalPhotos.pdf | Internal Photos | 2017-06-30 | PDF 1 MB |
| ExternalPhotos.pdf | External Photos | 2017-06-30 | PDF 505.4 KB |
| Label.pdf | ID Label/Location Info | 2017-06-01 | PDF 164.6 KB |
| TestSetupPhotos.pdf | Test Setup Photos | 2017-06-30 | PDF 753.8 KB |
| TestReport.pdf | Test Report | 2017-06-01 | PDF 4 MB |
| ConfidentialityRequest.pdf | Cover Letter(s) | 2017-06-01 | PDF 29 KB |
| ShortTermConf.pdf | Cover Letter(s) | 2017-06-01 | PDF 32.6 KB |
| RFExposure.pdf | RF Exposure Info | 2017-06-01 | PDF 262.2 KB |
| Block_diagram.pdf Metadata only | Block Diagram | PDF 48.4 KB | |
| Schematics.pdf Metadata only | Schematics | PDF 95.7 KB | |
| OperationalDecsription.pdf Metadata only | Operational Description | PDF 41 KB |
Application Information
| Application ID | 1kNlMKQ9ps8JyTeKjde6cg== |
|---|---|
| Final Action Date | 2017-06-01 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018318881 |
| Model | 122 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Accu-Check Instant |
| Responsible Party | Tony Heleine, Principal R&D; Engineer, tony.heleine@Roche.com |
| Test Firm | Gerald Schmidt, CTC advanced GmbH, mail@ctcadvanced.com |
| TCB Email | Oliver.Kneip@ctcadvanced.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 06/30/2017 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is peak conducted. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 1kNlMKQ9ps8JyTeKjde6cg== | 2017-06-01 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2402-2480 MHz | 0.0007800 | 15C |
Grants
TCB Grant - Application 1kNlMKQ9ps8JyTeKjde6cg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CTC advanced GmbH Untertuerkheimer Strasse 6-10 66117 Saarbruecken, Germany |
Date of Grant: 06/01/2017 Application Dated: 06/01/2017 |
| Roche Diabetes Care |
| 9115 Hague Road |
| Indianapolis, IN 46256 |
| Attention: Tony Heleine , Principal R&D Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | WX3-122 |
| Name of Grantee: | Roche Diabetes Care |
| Equipment Class: | Digital Transmission System |
| Notes: | Accu-Check Instant |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.00078 |
| Output power listed is peak conducted. |
EAS Grant - Application 1kNlMKQ9ps8JyTeKjde6cg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Roche Diabetes Care 9115 Hague Road Indianapolis, IN 46256 United States |
Date of Grant: 06/01/2017 Application Dated: 06/01/2017 |
| Attention: Tony Heleine , Principal R&D Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | WX3-122 |
| Name of Grantee: | Roche Diabetes Care |
| Equipment Class: | Digital Transmission System |
| Notes: | Accu-Check Instant |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.00078 |
| Output power listed is peak conducted. |
| Mail To: |