FCC ID WX3-415

Blood Glucose Meter

by Roche Diabetes Care

Grantee Code: WX3   Product Code: 415
Latest application date: 2021-09-17

FCC ID Device Details

FCC IDWX3-415
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeWX3
Product Code415
Applicant BusinessRoche Diabetes Care 🇺🇸
Related Domains roche.com
Equipment ClassBlood Glucose Meter
Test FirmElite Electronic Engineering Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2021-09-17

Exhibits

DocumentTypeAvailableFile
Exhibit D Users Manual per 2 1033 b3Users Manual2022-03-15PDF 1.9 MB
Exhibit C Internal PhotographsInternal Photos2022-03-15PDF 988.9 KB
Exhibit C External PhotographsExternal Photos2022-03-15PDF 456.2 KB
Exhibit A ID Label and location per 2 1033 b7ID Label/Location Info2021-09-17PDF 318.5 KB
Exhibit C RE Test Setup photographsTest Setup Photos2022-03-15PDF 760.4 KB
Exhibit E Test Measurement Report Part 1Test Report2021-09-17PDF 2.8 MB
Exhibit E Test Measurement Report Part 2Test Report2021-09-17PDF 1.6 MB
Agent Authorization LetterCover Letter(s)2021-09-17PDF 194.9 KB
Cover Letter Detailing Reason for FilingCover Letter(s)2021-09-17PDF 193.5 KB
Cover Letter Requesting ConfidentialityCover Letter(s)2021-09-17PDF 409.7 KB
Misc RF Exposure ExhibitsRF Exposure Info2021-09-17PDF 79.7 KB
Exhibit B Block Diagram per 2 1033 b5 Metadata onlyBlock DiagramPDF 238 KB
Exhibit B Schematics per 2 1033 c10 Metadata onlySchematicsPDF 126.8 KB
Exhibit B Operational Description per 2 1033 b4 Metadata onlyOperational DescriptionPDF 109.3 KB
Misc Parts List Exhibits Metadata onlyParts List/Tune Up InfoPDF 272.9 KB

Application Information

Application IDkEmjhBralL0StfE4kqUSCg==
Final Action Date2021-09-17
Application PurposeOriginal Equipment
Applicant FRN0018318881
Model415
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionBlood Glucose Meter
Responsible PartyTony Heleine, Principal R&D; Engineer, tony.heleine@Roche.com , 3175213404
Technical ContactTony L Heleine, Roche Diabetes Care, Inc., tony.heleine@roche.com , 3173196251
Non-Technical ContactDave Chandler, Roche Diabetes Care, Inc., dave.chandler@roche.com , 4632399780
Test FirmKevin Halpin, Elite Electronic Engineering Inc., khalpin@elitetest.com , 630-495-9770
TCB Emailreking@elitetest.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/15/2022
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is Conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter device, except as described in this filing or in accordance with FCC multi-transmitter product procedures. This filing meets the SAR threshold exclusion set forth in KDB 447498.

Applications

Application IDDatePurpose
kEmjhBralL0StfE4kqUSCg==2021-09-17Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.000500015C

Grants

TCB Grant - Application kEmjhBralL0StfE4kqUSCg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Elite Electronic Engineering, Inc.
1516 Centre Circle
Downers Grove, IL 60515
Date of Grant: 09/17/2021

Application Dated: 09/16/2021
Roche Diabetes Care
9115 Hague Road
Indianapolis, IN 46256
 
Attention: Tony Heleine , Principal R&D Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WX3-415
Name of Grantee:  Roche Diabetes Care
Equipment Class: Digital Transmission System
Notes: Blood Glucose Meter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0005  

Power Output is Conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter device, except as described in this filing or in accordance with FCC multi-transmitter product procedures. This filing meets the SAR threshold exclusion set forth in KDB 447498.

EAS Grant - Application kEmjhBralL0StfE4kqUSCg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Roche Diabetes Care
9115 Hague Road
Indianapolis, IN 46256
United States
  Date of Grant: 09/17/2021

Application Dated: 09/16/2021
 
Attention: Tony Heleine , Principal R&D Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  WX3-415
Name of Grantee:  Roche Diabetes Care
Equipment Class: Digital Transmission System
Notes: Blood Glucose Meter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0005  

Power Output is Conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter device, except as described in this filing or in accordance with FCC multi-transmitter product procedures. This filing meets the SAR threshold exclusion set forth in KDB 447498.



Mail To: