FCC ID X44-PRONTO7

Pronto 7 Spot Check Pulse CO-Oximeter

by Cercacor Laboratories, Inc.

Grantee Code: X44   Product Code: PRONTO7
Latest application date: 2010-03-12

FCC ID Device Details

FCC IDX44-PRONTO7
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeX44
Product CodePRONTO7
Applicant BusinessCercacor Laboratories, Inc. 🇺🇸
Related Domains cercacor.com
Equipment ClassPronto 7 Spot Check Pulse CO-Oximeter
Test FirmIntertek Testing Services NA

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2462 MHzOriginal Equipment2010-03-12

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2010-03-12PDF 1,003.1 KB
Internal PhotosInternal Photos2010-03-12PDF 1.3 MB
External PhotosExternal Photos2010-03-12PDF 693.3 KB
LabelID Label/Location Info2010-03-12PDF 557.2 KB
Test set up photosTest Setup Photos2010-03-12PDF 1.3 MB
SAR Test ReportRF Exposure Info2010-03-12PDF 3.5 MB
Test ReportTest Report2010-03-12PDF 991.6 KB
Confidentiality requestCover Letter(s)2010-03-12PDF 185.3 KB

Application Information

Application IDiwVfyPOQfVzy/SL7D3uvoQ==
Final Action Date2010-03-12
Application PurposeOriginal Equipment
Applicant FRN0019504166
Model-PRONTO7
Frequency Range2402-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionPronto 7 Spot Check Pulse CO-Oximeter
Responsible PartyHoward Chan, hchan@cercacor.com , 949-679-0608
AgentYuriy Yuriy Yuriy, Intertek, yuriy.litvinov@intertek.com , 6517301188
Technical ContactHoward Chan, Masimo Labs, Inc., hchan@masimolabs.com , 949-900-6614
Test FirmJames Sudduth, Intertek Testing Services NA, james.sudduth@intertek.com , 859-226-1037
TCB Emailtcb_admin@intertek.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR compliance for specific collocated transmitter conditions was evaluated in this filing; other co-located configurations require separate evaluation. SAR was evaluated for held-to-body operating mode. The maximum reported body-SAR value is 0.00145 W/kg.

Applications

Application IDDatePurpose
iwVfyPOQfVzy/SL7D3uvoQ==2010-03-12Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.000115C
2402-2462 MHz0.3115C

Grants

TCB Grant - Application iwVfyPOQfVzy/SL7D3uvoQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Intertek Testing Services NA, Inc.
70 Codman Hill Road
Boxborough, MA 01719
Date of Grant: 03/12/2010

Application Dated: 03/12/2010
Cercacor Laboratories, Inc.
189 Technology Dr
Irvine, CA 92618
 
Attention: Howard Chan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  X44-PRONTO7
Name of Grantee:  Cercacor Laboratories, Inc.
Equipment Class: Digital Transmission System
Notes: Pronto 7 Spot Check Pulse CO-Oximeter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0001  
15C 2402.0  -  2462.0 0.31  

Power listed is conducted. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR compliance for specific collocated transmitter conditions was evaluated in this filing; other co-located configurations require separate evaluation. SAR was evaluated for held-to-body operating mode. The maximum reported body-SAR value is 0.00145 W/kg.

EAS Grant - Application iwVfyPOQfVzy/SL7D3uvoQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cercacor Laboratories, Inc.
189 Technology Dr
Irvine, CA 92618
United States
  Date of Grant: 03/12/2010

Application Dated: 03/12/2010
 
Attention: Howard Chan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  X44-PRONTO7
Name of Grantee:  Cercacor Laboratories, Inc.
Equipment Class: Digital Transmission System
Notes: Pronto 7 Spot Check Pulse CO-Oximeter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0001  
15C 2402.0  -  2462.0 0.31  

Power listed is conducted. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. SAR compliance for specific collocated transmitter conditions was evaluated in this filing; other co-located configurations require separate evaluation. SAR was evaluated for held-to-body operating mode. The maximum reported body-SAR value is 0.00145 W/kg.



Mail To: