FCC ID X7H-M2MW02

Wireless Monitor Controller

by Commtiva Technology Taiwan Ltd

Grantee Code: X7H   Product Code: M2MW02
Latest application date: 2010-07-21

FCC ID Device Details

FCC IDX7H-M2MW02
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeX7H
Product CodeM2MW02
Applicant BusinessCommtiva Technology Taiwan Ltd 🇹🇼
Related Domains commtiva.com
Equipment ClassWireless Monitor Controller
Test FirmQuietek Linkou EMC Labotorty

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2010-07-21

Exhibits

DocumentTypeAvailableFile
UseManualUsers Manual2010-07-21PDF 865.5 KB
IntPhoInternal Photos2010-07-21PDF 850.9 KB
ExPhoExternal Photos2010-07-21PDF 72.7 KB
LabelLocID Label/Location Info2010-07-21PDF 93.4 KB
LabelSmpID Label/Location Info2010-07-21PDF 93.4 KB
Tsup-Part22&24Test Setup Photos2010-07-21PDF 264.5 KB
TestRpt-FCC Part22&24 0720Test Report2010-07-21PDF 2.6 MB
AttestationCover Letter(s)2010-07-21PDF 47.3 KB
ConfidentialityCover Letter(s)2010-07-21PDF 83.7 KB
Declaration of AuthorizationCover Letter(s)2010-07-21PDF 52.5 KB
Declaration of ConformityCover Letter(s)2010-07-21PDF 58 KB
RFExp-M2M-W02 0720RF Exposure Info2010-07-21PDF 38.1 KB

Application Information

Application IDC9t1EaPlCLEP/kKlI5H14Q==
Final Action Date2010-07-21
Application PurposeOriginal Equipment
Applicant FRN0019612597
Model-M2MW02
Frequency Range824.2-848.8 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionWireless Monitor Controller
Responsible PartyAuron Hung, auron.hung@commtiva.com , +886222685698
Technical ContactSabina Chen, QuieTek Corporation, sabinachen@quietek.com , 886-2-8601-3788
Test FirmJames Chang, Quietek Linkou EMC Labotorty, jameschang@quietek.com , 886-2-8792-6808
TCB Emailhotline@atcb.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower out is conducted at the antenna terminal. ERP for part 22 is 1.52W and EIRP for part 24 is 1.26W. This device is to be used only for mobile and fixed application. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device contains GSM function that are not operational in U.S. Territories. This filing is only applicable for 850 MHz Cell and 1900 MHz PCS operations.

Applications

Application IDDatePurpose
C9t1EaPlCLEP/kKlI5H14Q==2010-07-21Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz1.790.1ppm300KGXW22HBC
1850.2-1909.8 MHz1.070.1ppm300KGXW24EBC

Grants

TCB Grant - Application C9t1EaPlCLEP/kKlI5H14Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 07/21/2010

Application Dated: 07/18/2010
Commtiva Technology Taiwan Ltd
4F., No.32, Zhongcheng Rd., Tucheng Dist.
New Taipei City,
Taiwan
 
Attention: Auron Hung

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  X7H-M2MW02
Name of Grantee:  Commtiva Technology Taiwan Ltd
Equipment Class: PCS Licensed Transmitter
Notes: Wireless Monitor Controller
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 1.79 0.1  PM 300KGXW
BC 24E 1850.2  -  1909.8 1.07 0.1  PM 300KGXW

Power out is conducted at the antenna terminal. ERP for part 22 is 1.52W and EIRP for part 24 is 1.26W. This device is to be used only for mobile and fixed application. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device contains GSM function that are not operational in U.S. Territories. This filing is only applicable for 850 MHz Cell and 1900 MHz PCS operations.

BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application C9t1EaPlCLEP/kKlI5H14Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Commtiva Technology Taiwan Ltd
4F., No.32, Zhongcheng Rd., Tucheng Dist.
New Taipei City,
Taiwan
  Date of Grant: 07/21/2010

Application Dated: 07/18/2010
 
Attention: Auron Hung

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  X7H-M2MW02
Name of Grantee:  Commtiva Technology Taiwan Ltd
Equipment Class: PCS Licensed Transmitter
Notes: Wireless Monitor Controller
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 1.79 0.1  PM 300KGXW
BC 24E 1850.2  -  1909.8 1.07 0.1  PM 300KGXW

Power out is conducted at the antenna terminal. ERP for part 22 is 1.52W and EIRP for part 24 is 1.26W. This device is to be used only for mobile and fixed application. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This device contains GSM function that are not operational in U.S. Territories. This filing is only applicable for 850 MHz Cell and 1900 MHz PCS operations.