FCC ID XE2TF8

T2000 AEI Reader

by Thinkify LLC

Grantee Code: XE2   Product Code: TF8
Latest application date: 2015-09-18

FCC ID Device Details

FCC IDXE2TF8
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXE2
Product CodeTF8
Applicant BusinessThinkify LLC 🇺🇸
Related Domains thinkifyit.com
Equipment ClassT2000 AEI Reader
Test FirmMicom Labs

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.5-903.5 MHzOriginal Equipment2015-09-18

Exhibits

DocumentTypeAvailableFile
Draft Manual Metadata onlyUsers Manual2015-09-18PDF 99.5 KB
Int Metadata onlyInternal Photos2015-09-18PDF 2.4 MB
Ext Metadata onlyExternal Photos2015-09-18PDF 2.4 MB
LabelID Label/Location Info2015-09-18PDF 46.6 KB
Setup Metadata onlyTest Setup Photos2015-09-18PDF 699.2 KB
Test ReportTest Report2015-09-18PDF 1.8 MB
AuthorizationCover Letter(s)2015-09-18PDF 499.9 KB
ConfidCover Letter(s)2015-09-18PDF 878.8 KB
RFxRF Exposure Info2015-09-18PDF 177.9 KB
Block Metadata onlyBlock DiagramPDF 87 KB
Schema Metadata onlySchematicsPDF 564 KB
Ops Metadata onlyOperational DescriptionPDF 79.1 KB
Parts Metadata onlyParts List/Tune Up InfoPDF 98.7 KB
Tune Up Metadata onlyParts List/Tune Up InfoPDF 109.8 KB

Application Information

Application IDeZC7U5E4t14NzMIkCMoztg==
Final Action Date2015-09-18
Application PurposeOriginal Equipment
Applicant FRN0018801704
ModelTF8
Frequency Range902.5-903.5 MHz
Equipment ClassLMS - Part 90 Location & Monitoring Transmitter
Device DescriptionT2000 AEI Reader
Responsible PartyCurt L Carrender, curt@thinkifyit.com , 408-782-7111
Technical ContactGordon Hurst, MiCOM Labs, certification@micomlabs.com , (925)4620304
Test FirmGordon Hurst, Micom Labs, gordon_hurst@micomlabs.com , 925-462-0304
TCB Emailcertification@micomlabs.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/16/2016
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output listed is Conducted. This device must be professionally installed. The peak radiated output power, including antenna gain and cable loss, must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 117 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The maximum antenna height above ground for non-multilateration LMS systems is 15 meters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
eZC7U5E4t14NzMIkCMoztg==2015-09-18Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
902.5-903.5 MHz3.0130.35ppmNON90.3532
910-921 MHz2.9720.35ppmNON90.3532

Grants

TCB Grant - Application eZC7U5E4t14NzMIkCMoztg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 09/18/2015

Application Dated: 09/18/2015
Thinkify LLC
18450 Technology Drive
Suite E
Morgan Hill, CA 95037
 
Attention: Curt Carrender

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XE2TF8
Name of Grantee:  Thinkify LLC
Equipment Class: Part 90 Location & Monitoring Transmitter
Notes: T2000 AEI Reader
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 90.353 902.5  -  903.5 3.013 0.35  PM NON
20 90.353 910.0  -  921.0 2.972 0.35  PM NON

Power Output listed is Conducted. This device must be professionally installed. The peak radiated output power, including antenna gain and cable loss, must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 117 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The maximum antenna height above ground for non-multilateration LMS systems is 15 meters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

EAS Grant - Application eZC7U5E4t14NzMIkCMoztg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Thinkify LLC
18450 Technology Drive Suite E
Morgan Hill, CA 95037
United States
  Date of Grant: 09/18/2015

Application Dated: 09/18/2015
 
Attention: Curt Carrender

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XE2TF8
Name of Grantee:  Thinkify LLC
Equipment Class: Part 90 Location & Monitoring Transmitter
Notes: T2000 AEI Reader
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
20 90.353 902.5  -  903.5 3.013 0.35  PM NON
20 90.353 910.0  -  921.0 2.972 0.35  PM NON

Power Output listed is Conducted. This device must be professionally installed. The peak radiated output power, including antenna gain and cable loss, must not exceed 30 W ERP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 117 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The maximum antenna height above ground for non-multilateration LMS systems is 15 meters. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


20: All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed.

Mail To: