FCC ID XEK-MEGASCANM1

UHF RFID Reader

by Megabyte Limited

Grantee Code: XEK   Product Code: MEGASCANM1
Latest application date: 2009-08-31

FCC ID Device Details

FCC IDXEK-MEGASCANM1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXEK
Product CodeMEGASCANM1
Applicant BusinessMegabyte Limited
Related Domains scanmega.com adt.com.tw
Equipment ClassUHF RFID Reader
Test FirmBureau Veritas CPS (H.K.) Ltd. Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.75-927.25 MHzOriginal Equipment2009-08-31

Exhibits

DocumentTypeAvailableFile
User manual rev2Users Manual2009-08-31PDF 387.2 KB
Internal photosInternal Photos2009-08-31PDF 924.6 KB
External photosExternal Photos2009-08-31PDF 289.6 KB
Label location revID Label/Location Info2009-08-31PDF 30.9 KB
Label sample revID Label/Location Info2009-08-31PDF 42.3 KB
Test setup photos revTest Setup Photos2009-08-31PDF 97.8 KB
Test report 1 revTest Report2009-08-31PDF 1 MB
Test report 2 revTest Report2009-08-31PDF 208.7 KB
Test report 3 revTest Report2009-08-31PDF 91.4 KB
General declaration revAttestation Statements2009-08-31PDF 415.4 KB
Professional installation declarationAttestation Statements2009-08-31PDF 237.1 KB
Confidentiality request revCover Letter(s)2009-08-31PDF 673.8 KB
POA revCover Letter(s)2009-08-31PDF 668.8 KB
RF exposureRF Exposure Info2009-08-31PDF 44.3 KB

Application Information

Application ID42hZx0DGvIaCiIHeUuYymg==
Final Action Date2009-08-31
Application PurposeOriginal Equipment
Applicant FRN0018792465
Model-MEGASCANM1
Frequency Range902.75-927.25 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionUHF RFID Reader
Responsible PartyMatthew Chun Sing Man, CEO, info@scanmega.com , 2144 2004
Technical ContactEric Lin, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, eric_lin@adt.com.tw , 886-3-593-5343
Non-Technical ContactEric Lin, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, eric_lin@adt.com.tw , 886-3-593-5343
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-2-2605-2180-3
TCB Emailcertification@curtis-straus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is conducted. This device must be professionally installed. Marketing to the General Public is prohibited. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. The use of other antenna requires a Class II Permissive Change filing. The antennas used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End -users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
42hZx0DGvIaCiIHeUuYymg==2009-08-31Original Equipment

Equipment Authorization

FrequencyOutputRules
902.75-927.25 MHz0.912000015C

Grants

TCB Grant - Application 42hZx0DGvIaCiIHeUuYymg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 08/31/2009

Application Dated: 08/28/2009
Megabyte Limited
Unit 518, 5/F, Enterprise Place, No. 5 Science Par
Hong Kong Science Park, Shatin, N.T.
Hong Kong, 852
Hong Kong
 
Attention: Matthew Chun Sing Man , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XEK-MEGASCANM1
Name of Grantee:  Megabyte Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: UHF RFID Reader
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.75  -  927.25 0.912  

Output Power listed is conducted. This device must be professionally installed. Marketing to the General Public is prohibited. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. The use of other antenna requires a Class II Permissive Change filing. The antennas used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End -users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application 42hZx0DGvIaCiIHeUuYymg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Megabyte Limited
Unit 518, 5/F, Enterprise Place, No. 5 Science Par Hong Kong Science Park, Shatin, N.T.P.O. Box ,
Hong Kong, 852
Hong Kong
  Date of Grant: 08/31/2009

Application Dated: 08/28/2009
 
Attention: Matthew Chun Sing Man , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XEK-MEGASCANM1
Name of Grantee:  Megabyte Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: UHF RFID Reader
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.75  -  927.25 0.912  

Output Power listed is conducted. This device must be professionally installed. Marketing to the General Public is prohibited. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. The use of other antenna requires a Class II Permissive Change filing. The antennas used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End -users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: