FCC ID XHM-P2230000

Handheld Terminal

by FLYTECH TECHNOLOGY CO., LTD

Grantee Code: XHM   Product Code: P2230000
Latest application date: 2010-09-24

FCC ID Device Details

FCC IDXHM-P2230000
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXHM
Product CodeP2230000
Applicant BusinessFLYTECH TECHNOLOGY CO., LTD 🇹🇼
Related Domains flytech.com.tw neutron.com.tw
Equipment ClassHandheld Terminal
Test FirmBTL Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2010-09-24

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2010-09-24PDF 1.9 MB
int pho cradleInternal Photos2010-09-24PDF 243.2 KB
int pho s1Internal Photos2010-09-24PDF 1.6 MB
int pho s2Internal Photos2010-09-24PDF 943.7 KB
ext phoExternal Photos2010-09-24PDF 1.1 MB
labelID Label/Location Info2010-09-24PDF 158 KB
setup pho blTest Setup Photos2010-09-24PDF 266.7 KB
setup pho wlanTest Setup Photos2010-09-24PDF 190.1 KB
test report blTest Report2010-09-24PDF 3.1 MB
test report wlanTest Report2010-09-24PDF 1.7 MB
DoACover Letter(s)2010-09-24PDF 15.1 KB
confCover Letter(s)2010-09-24PDF 26.5 KB
docCover Letter(s)2010-09-24PDF 1 MB
calibration rep1RF Exposure Info2010-09-24PDF 291.5 KB
calibration rep2RF Exposure Info2010-09-24PDF 291.5 KB
calibration rep3RF Exposure Info2010-09-24PDF 2.8 MB
sar reportRF Exposure Info2010-09-24PDF 558.4 KB
testplotRF Exposure Info2010-09-24PDF 494.2 KB

Application Information

Application IDYUEN2injTyVwB+OW8aZ92A==
Final Action Date2010-09-24
Application PurposeOriginal Equipment
Applicant FRN0018869826
Model-P2230000
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionHandheld Terminal
Responsible PartyAvin Zhan, avinchan@flytech.com.tw , 886-2-8791-4988
AgentNeutron Engineering Inc., kate@neutron.com.tw
Non-Technical ContactKate Lin, Neutron Engineering Inc., kate@neutron.com.tw , +886-2-2657-3299
Test FirmAndy Chiu, BTL Inc., Andy@newbtl.com , 886-2-2657-3299
TCB Emailcertification@telefication.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Bodyworn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR value: 0.683 W/kg (body).

Applications

Application IDDatePurpose
YUEN2injTyVwB+OW8aZ92A==2010-09-24Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001415C
2412-2462 MHz0.130315C

Grants

TCB Grant - Application YUEN2injTyVwB+OW8aZ92A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Edisonstraat 12a
Zevenaar, NL-6902 PK
Netherlands
Date of Grant: 09/24/2010

Application Dated: 09/17/2010
FLYTECH TECHNOLOGY CO., LTD
No. 168, Sing-ai Rd., Neihu District, Taipei City
Taipei City,
Taiwan
 
Attention: Avin Zhan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XHM-P2230000
Name of Grantee:  FLYTECH TECHNOLOGY CO., LTD
Equipment Class: Digital Transmission System
Notes: Handheld Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0014  
15C 2412.0  -  2462.0 0.1303  

Power output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Bodyworn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR value: 0.683 W/kg (body).

EAS Grant - Application YUEN2injTyVwB+OW8aZ92A==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

FLYTECH TECHNOLOGY CO., LTD
No. 168, Sing-ai Rd., Neihu District, Taipei City P.O. Box ,
Taipei City,
Taiwan
  Date of Grant: 09/24/2010

Application Dated: 09/17/2010
 
Attention: Avin Zhan

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XHM-P2230000
Name of Grantee:  FLYTECH TECHNOLOGY CO., LTD
Equipment Class: Digital Transmission System
Notes: Handheld Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0014  
15C 2412.0  -  2462.0 0.1303  

Power output listed is conducted. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Bodyworn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. Highest reported SAR value: 0.683 W/kg (body).



Mail To: