FCC ID XM2-EP7FL8P9PP
Remote Unit Enhanced Power
by Teko Telecom Srl
Grantee Code: XM2 Product Code: EP7FL8P9PP
Latest application date: 2017-08-30
FCC ID Device Details
| FCC ID | XM2-EP7FL8P9PP |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XM2 |
| Product Code | EP7FL8P9PP |
| Applicant Business | Teko Telecom Srl 🇮🇹 |
| Related Domains | |
| Equipment Class | Remote Unit Enhanced Power |
| Test Firm | Nemko S.p.A. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 929-930 MHz | Original Equipment | 2017-08-30 |
| 928-929 MHz | Original Equipment | 2017-08-30 |
| 758-768 MHz | Original Equipment | 2017-08-30 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| external photos | External Photos | 2017-08-30 | PDF 820.5 KB |
| label and location | ID Label/Location Info | 2017-08-30 | PDF 796.2 KB |
| test report 1 758-768 MHz | Test Report | 2017-08-30 | PDF 2.5 MB |
| test report 10 940-941 MHz | Test Report | 2017-08-30 | PDF 991.6 KB |
| test report 2 769-775 MHz | Test Report | 2017-08-30 | PDF 1.3 MB |
| test report 3 851-862 MHz | Test Report | 2017-08-30 | PDF 1.5 MB |
| test report 4 928-929 MHz | Test Report | 2017-08-30 | PDF 1.3 MB |
| test report 5 929-930 MHz | Test Report | 2017-08-30 | PDF 1.2 MB |
| test report 6 930-931 MHz | Test Report | 2017-08-30 | PDF 1 MB |
| test report 7 931-932 MHz | Test Report | 2017-08-30 | PDF 1.3 MB |
| test report 8 932-935 MHz | Test Report | 2017-08-30 | PDF 1.4 MB |
| test report 9 935-940 MHz | Test Report | 2017-08-30 | PDF 1.2 MB |
| agent letter | Cover Letter(s) | 2017-08-30 | PDF 288.1 KB |
| confidential letter with NDA | Cover Letter(s) | 2017-08-30 | PDF 563.4 KB |
| signal booster letter | Cover Letter(s) | 2017-08-30 | PDF 230.5 KB |
| MPE | RF Exposure Info | 2017-08-30 | PDF 32 KB |
| user manual Metadata only | Users Manual | PDF 5.3 MB | |
| internal photos Metadata only | Internal Photos | PDF 993.7 KB | |
| block diagram Metadata only | Block Diagram | PDF 235 KB | |
| schematics Metadata only | Schematics | PDF 1 MB | |
| operational description Metadata only | Operational Description | PDF 393.3 KB | |
| parts list Metadata only | Parts List/Tune Up Info | PDF 192.9 KB | |
| tune up info Metadata only | Parts List/Tune Up Info | PDF 230.4 KB |
Application Information
| Application ID | ppcrUICy7PvXJPb58bHDsA== |
|---|---|
| Final Action Date | 2017-08-30 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018963462 |
| Model | EP7FL8P9PP |
| Frequency Range | 929-930 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | Remote Unit Enhanced Power |
| Responsible Party | Alessandro Brunelli, Certification Engineer, abrunelli@jmawireless.com |
| Test Firm | Roberto Giampaglia, Nemko S.p.A., segreteria@nemko.com |
| TCB Email | stuart.beck@nemko.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ppcrUICy7PvXJPb58bHDsA== | 2017-08-30 | Original Equipment |
| WBjQ/VNm1jmZeCQffXNfzA== | 2017-08-30 | Original Equipment |
| C7CkXjoyy58y25UyuQtcAg== | 2017-08-30 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 769-775 MHz | 1.25 | Amp | F1E | 9 |
| 769-775 MHz | 1.25 | Amp | F1D | 9 |
| 769-775 MHz | 1.25 | Amp | F3E | 9 |
| 851-862 MHz | 1.25 | Amp | F1E | 9 |
| 851-862 MHz | 1.25 | Amp | F1D | 9 |
| 851-862 MHz | 1.25 | Amp | F3E | 9 |
| 928-929 MHz | 1.25 | Amp | F1E | 101 |
| 928-929 MHz | 1.25 | Amp | F1D | 101 |
| 928-929 MHz | 1.25 | Amp | F3E | 101 |
| 929-930 MHz | 1.25 | Amp | F3E | 9 |
| 929-930 MHz | 1.25 | Amp | F1D | 22 |
| 929-930 MHz | 1.25 | Amp | F3E | 22 |
| 929-930 MHz | 1.25 | Amp | F1E | 9 |
| 929-930 MHz | 1.25 | Amp | F1D | 9 |
| 930-931 MHz | 1.25 | Amp | D7W | 24D |
| 931-932 MHz | 1.25 | Amp | F1E | 22 |
| 931-932 MHz | 1.25 | Amp | F1D | 22 |
| 931-932 MHz | 1.25 | Amp | F3E | 22 |
| 932-935 MHz | 1.25 | Amp | F1E | 101 |
| 932-935 MHz | 1.25 | Amp | F1D | 101 |
| 932-935 MHz | 1.25 | Amp | F3E | 101 |
| 935-940 MHz | 1.25 | Amp | F3E | 90S |
| 935-940 MHz | 1.25 | Amp | F1E | 9 |
| 935-940 MHz | 1.25 | Amp | F1D | 9 |
| 935-940 MHz | 1.25 | Amp | F3E | 9 |
| 935-940 MHz | 1.25 | Amp | F1E | 90S |
| 935-940 MHz | 1.25 | Amp | F1D | 90S |
| 940-941 MHz | 1.25 | Amp | D7W | 24D |
Grants
TCB Grant - Application WBjQ/VNm1jmZeCQffXNfzA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 08/30/2017 Application Dated: 08/30/2017 |
| Teko Telecom Srl |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-EP7FL8P9PP |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | Remote Unit Enhanced Power |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 101 | 928.0 - 929.0 | 1.25 | Amp | F1E | |
| 101 | 928.0 - 929.0 | 1.25 | Amp | F1D | |
| 101 | 928.0 - 929.0 | 1.25 | Amp | F3E | |
| 101 | 932.0 - 935.0 | 1.25 | Amp | F1E | |
| 101 | 932.0 - 935.0 | 1.25 | Amp | F1D | |
| 101 | 932.0 - 935.0 | 1.25 | Amp | F3E |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
EAS Grant - Application WBjQ/VNm1jmZeCQffXNfzA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Teko Telecom Srl Via Meucci 24/A Castel San Pietro Terme BO, 40024 Italy |
Date of Grant: 08/30/2017 Application Dated: 08/30/2017 |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-EP7FL8P9PP |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | Remote Unit Enhanced Power |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 101 | 928.0 - 929.0 | 1.25 | Amp | F1E | |
| 101 | 928.0 - 929.0 | 1.25 | Amp | F1D | |
| 101 | 928.0 - 929.0 | 1.25 | Amp | F3E | |
| 101 | 932.0 - 935.0 | 1.25 | Amp | F1E | |
| 101 | 932.0 - 935.0 | 1.25 | Amp | F1D | |
| 101 | 932.0 - 935.0 | 1.25 | Amp | F3E |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 08/30/2017 Application Dated: 08/29/2017 |
| Teko Telecom Srl |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-EP7FL8P9PP |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit Enhanced Power |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22 | 929.0 - 930.0 | 1.25 | Amp | F1E | |
| 22 | 929.0 - 930.0 | 1.25 | Amp | F1D | |
| 22 | 929.0 - 930.0 | 1.25 | Amp | F3E | |
| 24D | 930.0 - 931.0 | 1.25 | Amp | D7W | |
| 22 | 931.0 - 932.0 | 1.25 | Amp | F1E | |
| 22 | 931.0 - 932.0 | 1.25 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 1.25 | Amp | F3E | |
| 90S | 935.0 - 940.0 | 1.25 | Amp | F1E | |
| 90S | 935.0 - 940.0 | 1.25 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 1.25 | Amp | F3E | |
| 24D | 940.0 - 941.0 | 1.25 | Amp | D7W |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
EAS Grant - Application ppcrUICy7PvXJPb58bHDsA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Teko Telecom Srl Via Meucci 24/A Castel San Pietro Terme BO, 40024 Italy |
Date of Grant: 08/30/2017 Application Dated: 08/29/2017 |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-EP7FL8P9PP |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit Enhanced Power |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22 | 929.0 - 930.0 | 1.25 | Amp | F1E | |
| 22 | 929.0 - 930.0 | 1.25 | Amp | F1D | |
| 22 | 929.0 - 930.0 | 1.25 | Amp | F3E | |
| 24D | 930.0 - 931.0 | 1.25 | Amp | D7W | |
| 22 | 931.0 - 932.0 | 1.25 | Amp | F1E | |
| 22 | 931.0 - 932.0 | 1.25 | Amp | F1D | |
| 22 | 931.0 - 932.0 | 1.25 | Amp | F3E | |
| 90S | 935.0 - 940.0 | 1.25 | Amp | F1E | |
| 90S | 935.0 - 940.0 | 1.25 | Amp | F1D | |
| 90S | 935.0 - 940.0 | 1.25 | Amp | F3E | |
| 24D | 940.0 - 941.0 | 1.25 | Amp | D7W |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 08/30/2017 Application Dated: 08/30/2017 |
| Teko Telecom Srl |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-EP7FL8P9PP |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit Enhanced Power |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 758.0 - 768.0 | 1.25 | Amp | D7W |
| 90 | 769.0 - 775.0 | 1.25 | Amp | F1E | |
| 90 | 769.0 - 775.0 | 1.25 | Amp | F1D | |
| 90 | 769.0 - 775.0 | 1.25 | Amp | F3E | |
| 90 | 851.0 - 862.0 | 1.25 | Amp | F1E | |
| 90 | 851.0 - 862.0 | 1.25 | Amp | F1D | |
| 90 | 851.0 - 862.0 | 1.25 | Amp | F3E | |
| 90 | 929.0 - 930.0 | 1.25 | Amp | F1E | |
| 90 | 929.0 - 930.0 | 1.25 | Amp | F1D | |
| 90 | 929.0 - 930.0 | 1.25 | Amp | F3E | |
| 90 | 935.0 - 940.0 | 1.25 | Amp | F1E | |
| 90 | 935.0 - 940.0 | 1.25 | Amp | F1D | |
| 90 | 935.0 - 940.0 | 1.25 | Amp | F3E |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
| PF: | Transmitter approved for Public Safety Broadband |
EAS Grant - Application C7CkXjoyy58y25UyuQtcAg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Teko Telecom Srl Via Meucci 24/A Castel San Pietro Terme BO, 40024 Italy |
Date of Grant: 08/30/2017 Application Dated: 08/30/2017 |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-EP7FL8P9PP |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit Enhanced Power |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 758.0 - 768.0 | 1.25 | Amp | D7W |
| 90 | 769.0 - 775.0 | 1.25 | Amp | F1E | |
| 90 | 769.0 - 775.0 | 1.25 | Amp | F1D | |
| 90 | 769.0 - 775.0 | 1.25 | Amp | F3E | |
| 90 | 851.0 - 862.0 | 1.25 | Amp | F1E | |
| 90 | 851.0 - 862.0 | 1.25 | Amp | F1D | |
| 90 | 851.0 - 862.0 | 1.25 | Amp | F3E | |
| 90 | 929.0 - 930.0 | 1.25 | Amp | F1E | |
| 90 | 929.0 - 930.0 | 1.25 | Amp | F1D | |
| 90 | 929.0 - 930.0 | 1.25 | Amp | F3E | |
| 90 | 935.0 - 940.0 | 1.25 | Amp | F1E | |
| 90 | 935.0 - 940.0 | 1.25 | Amp | F1D | |
| 90 | 935.0 - 940.0 | 1.25 | Amp | F3E |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
| PF: | Transmitter approved for Public Safety Broadband |
| Mail To: |