FCC ID XM2-MP19HAWX2325

Remote Unit Medium Power

by Teko Telecom Srl

Grantee Code: XM2   Product Code: MP19HAWX2325
Latest application date: 2025-01-29

FCC ID Device Details

FCC IDXM2-MP19HAWX2325
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXM2
Product CodeMP19HAWX2325
Applicant BusinessTeko Telecom Srl 🇮🇹
Related Domains jmawireless.com
Equipment ClassRemote Unit Medium Power
Test FirmNemko S.p.A.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2496-2690 MHzClass II permissive change or modification of presently authorized equipment2025-01-29
1930-1995 MHzOriginal Equipment2019-07-19

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2025-01-29PDF 547.5 KB
external photosExternal Photos2019-07-19PDF 428.9 KB
LabelID Label/Location Info2025-01-29PDF 182 KB
Label LocationID Label/Location Info2025-01-29PDF 347.5 KB
labelID Label/Location Info2019-07-19PDF 146.5 KB
label locationID Label/Location Info2019-07-19PDF 451.7 KB
Test Setup PhotosTest Setup Photos2025-01-29PDF 824.8 KB
Test Report 1Test Report2025-01-29PDF 2.1 MB
Test Report 2Test Report2025-01-29PDF 2.2 MB
Test Report 3Test Report2025-01-29PDF 2.2 MB
Test Report 4Test Report2025-01-29PDF 2.1 MB
Test Report 5Test Report2025-01-29PDF 2.2 MB
372836-1TRFWL [1930-1995 MHz]Test Report2019-07-19PDF 3.5 MB
372836-2TRFWL [1995-2020 MHz]Test Report2019-07-19PDF 3.3 MB
372836-3TRFWL [2110-2180 MHz]Test Report2019-07-19PDF 2.2 MB
372836-4TRFWL [2180-2200 MHz]Test Report2019-07-19PDF 2.3 MB
372836-5TRFWL [2350-2360 MHz]Test Report2019-07-19PDF 2.3 MB
372836-6TRFWL [2496-2690 MHz]Test Report2019-07-19PDF 2.1 MB
Covered Equipment AttestationAttestation Statements2025-01-29PDF 108.1 KB
U.S. Agent Designation AttestationAttestation Statements2025-01-29PDF 155.6 KB
Warning Label AttestationCover Letter(s)2025-01-29PDF 112.5 KB
Agent Authorization LetterCover Letter(s)2025-01-29PDF 113.3 KB
Class II Permissive Change Request LetterCover Letter(s)2025-01-29PDF 184 KB
Confidentiality LetterCover Letter(s)2025-01-29PDF 274.7 KB
agent letterCover Letter(s)2019-07-19PDF 195.2 KB
confidential letterCover Letter(s)2019-07-19PDF 315.3 KB
warning label letterCover Letter(s)2019-07-19PDF 148.6 KB
RF Exposure EvaluationRF Exposure Info2025-01-29PDF 127.8 KB
MPERF Exposure Info2019-07-19PDF 29.2 KB
Users Manual Metadata onlyUsers ManualPDF 4.5 MB
user manual Metadata onlyUsers ManualPDF 4.9 MB
internal photos Metadata onlyInternal PhotosPDF 657 KB
block diagram Metadata onlyBlock DiagramPDF 161.7 KB
schematics Metadata onlySchematicsPDF 1.4 MB
operational description Metadata onlyOperational DescriptionPDF 264.5 KB
Tune Up Information Metadata onlyParts List/Tune Up InfoPDF 151.5 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 248.2 KB
tune up procedure Metadata onlyParts List/Tune Up InfoPDF 148.6 KB

Application Information

Application IDxWb+nl5X/q5Cyg2H0mQINA==
Final Action Date2025-01-29
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0018963462
ModelMP19HAWX2325
Frequency Range2496-2690 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device DescriptionRemote Unit Medium Power
Responsible PartyAlessandro Brunelli, Certification Engineer, abrunelli@jmawireless.com , +39 051 6946811
Test FirmRoberto Giampaglia, Nemko S.p.A., segreteria@nemko.com , +39 039 220 12 01
TCB EmailTCB@nemko.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47. Class II Permissive Change to add 5G NR modulation mode that supports 45 MHz bandwidth in 1930-1995 MHz and 2110-2200 MHz frequency bands, 25 MHz bandwidth in 1995-2020 MHz frequency band, 10 MHz bandwidth in 2350-2360 MHz frequency band and 100 MHz bandwidth in 2496-2690 MHz frequency band.

Applications

Application IDDatePurpose
xWb+nl5X/q5Cyg2H0mQINA==2025-01-29Class II permissive change or modification of presently authorized equipment
QqtROvPCVusBcFpRZZW34g==2019-07-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1930-1995 MHz2AmpGXW24E
1930-1995 MHz2AmpD7W24E
1995-2020 MHz2AmpF9W27
1995-2020 MHz2AmpGXW27
1995-2020 MHz2AmpD7W27
2110-2200 MHz2AmpF9W27
2110-2200 MHz2AmpD7W27
2350-2360 MHz2AmpD7W27
2496-2690 MHz2AmpD7W27

Grants

TCB Grant - Application xWb+nl5X/q5Cyg2H0mQINA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 01/29/2025

Application Dated: 01/28/2025
Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP19HAWX2325
Name of Grantee:  Teko Telecom Srl
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Remote Unit Medium Power
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1930.0  -  1995.0 2.0  Amp F9W
24E 1930.0  -  1995.0 2.0  Amp GXW
24E 1930.0  -  1995.0 2.0  Amp D7W
27 1995.0  -  2020.0 2.0  Amp F9W
27 1995.0  -  2020.0 2.0  Amp GXW
27 1995.0  -  2020.0 2.0  Amp D7W
27 2110.0  -  2200.0 2.0  Amp F9W
27 2110.0  -  2200.0 2.0  Amp D7W
27 2350.0  -  2360.0 2.0  Amp D7W
27 2496.0  -  2690.0 2.0  Amp D7W

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47.

Class II Permissive Change to add 5G NR modulation mode that supports 45 MHz bandwidth in 1930-1995 MHz and 2110-2200 MHz frequency bands, 25 MHz bandwidth in 1995-2020 MHz frequency band, 10 MHz bandwidth in 2350-2360 MHz frequency band and 100 MHz bandwidth in 2496-2690 MHz frequency band.


EAS Grant - Application xWb+nl5X/q5Cyg2H0mQINA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
  Date of Grant: 01/29/2025

Application Dated: 01/28/2025
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP19HAWX2325
Name of Grantee:  Teko Telecom Srl
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Remote Unit Medium Power
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1930.0  -  1995.0 2.0  Amp F9W
24E 1930.0  -  1995.0 2.0  Amp GXW
24E 1930.0  -  1995.0 2.0  Amp D7W
27 1995.0  -  2020.0 2.0  Amp F9W
27 1995.0  -  2020.0 2.0  Amp GXW
27 1995.0  -  2020.0 2.0  Amp D7W
27 2110.0  -  2200.0 2.0  Amp F9W
27 2110.0  -  2200.0 2.0  Amp D7W
27 2350.0  -  2360.0 2.0  Amp D7W
27 2496.0  -  2690.0 2.0  Amp D7W

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47.

Class II Permissive Change to add 5G NR modulation mode that supports 45 MHz bandwidth in 1930-1995 MHz and 2110-2200 MHz frequency bands, 25 MHz bandwidth in 1995-2020 MHz frequency band, 10 MHz bandwidth in 2350-2360 MHz frequency band and 100 MHz bandwidth in 2496-2690 MHz frequency band.



TCB Grant - Application QqtROvPCVusBcFpRZZW34g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 07/19/2019

Application Dated: 07/19/2019
Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP19HAWX2325
Name of Grantee:  Teko Telecom Srl
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Remote Unit Medium Power
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1930.0  -  1995.0 2.0  Amp F9W
24E 1930.0  -  1995.0 2.0  Amp GXW
24E 1930.0  -  1995.0 2.0  Amp D7W
27 1995.0  -  2020.0 2.0  Amp F9W
27 1995.0  -  2020.0 2.0  Amp GXW
27 1995.0  -  2020.0 2.0  Amp D7W
27 2110.0  -  2200.0 2.0  Amp F9W
27 2110.0  -  2200.0 2.0  Amp D7W
27 2350.0  -  2360.0 2.0  Amp D7W
27 2496.0  -  2690.0 2.0  Amp D7W

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47.

EAS Grant - Application QqtROvPCVusBcFpRZZW34g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
  Date of Grant: 07/19/2019

Application Dated: 07/19/2019
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP19HAWX2325
Name of Grantee:  Teko Telecom Srl
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Remote Unit Medium Power
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1930.0  -  1995.0 2.0  Amp F9W
24E 1930.0  -  1995.0 2.0  Amp GXW
24E 1930.0  -  1995.0 2.0  Amp D7W
27 1995.0  -  2020.0 2.0  Amp F9W
27 1995.0  -  2020.0 2.0  Amp GXW
27 1995.0  -  2020.0 2.0  Amp D7W
27 2110.0  -  2200.0 2.0  Amp F9W
27 2110.0  -  2200.0 2.0  Amp D7W
27 2350.0  -  2360.0 2.0  Amp D7W
27 2496.0  -  2690.0 2.0  Amp D7W

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47.



Mail To: