FCC ID XM2-MP6B
Remote Unit Medium Power
by JMA Innovazione S.r.l. a socio unico
Grantee Code: XM2 Product Code: MP6B
Latest application date: 2025-09-22
FCC ID Device Details
| FCC ID | XM2-MP6B |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XM2 |
| Product Code | MP6B |
| Applicant Business | JMA Innovazione S.r.l. a socio unico 🇮🇹 |
| Related Domains | |
| Equipment Class | Remote Unit Medium Power |
| Test Firm | Nemko S.p.A. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 758-768 MHz | Class II permissive change or modification of presently authorized equipment | 2025-09-22 |
| 2350-2360 MHz | Class II permissive change or modification of presently authorized equipment | 2025-09-22 |
| 728-758 MHz | Original Equipment | 2017-11-23 |
| 758-768 MHz | Original Equipment | 2017-11-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2025-09-22 | PDF 389.9 KB |
| external photos | External Photos | 2017-11-23 | PDF 522.5 KB |
| Label and Label Location | ID Label/Location Info | 2025-09-22 | PDF 478.5 KB |
| label and location | ID Label/Location Info | 2017-11-23 | PDF 730.9 KB |
| Test setup photos | Test Setup Photos | 2025-09-22 | PDF 575 KB |
| Test Report | Test Report | 2025-09-22 | PDF 2.1 MB |
| test report 1 728-746 MHz | Test Report | 2017-11-23 | PDF 2.3 MB |
| test report 10 2180-2200 MHz | Test Report | 2017-11-23 | PDF 1 MB |
| test report 11 2350-2360 MHz | Test Report | 2017-11-23 | PDF 2.4 MB |
| test report 2 746-758 MHz | Test Report | 2017-11-23 | PDF 1,015.8 KB |
| test report 3 758-768 MHz | Test Report | 2017-11-23 | PDF 1.3 MB |
| test report 4 858.5-869 MHz | Test Report | 2017-11-23 | PDF 2.7 MB |
| test report 5 869-894 MHz | Test Report | 2017-11-23 | PDF 2.7 MB |
| test report 6 1930-1995 MHz | Test Report | 2017-11-23 | PDF 2.8 MB |
| test report 7 1995-2000 MHz | Test Report | 2017-11-23 | PDF 2.8 MB |
| test report 8 2000-2200 MHz | Test Report | 2017-11-23 | PDF 2.8 MB |
| test report 9 2110-2180 MHz | Test Report | 2017-11-23 | PDF 2.4 MB |
| Attestation Letters | Attestation Statements | 2025-09-22 | PDF 191.8 KB |
| Confidentiality Letter | Cover Letter(s) | 2025-09-22 | PDF 374.1 KB |
| Cover Letters | Cover Letter(s) | 2025-09-22 | PDF 220.9 KB |
| DA 13-2409 | Cover Letter(s) | 2017-11-23 | PDF 152.7 KB |
| agent letter | Cover Letter(s) | 2017-11-23 | PDF 288.3 KB |
| confidential letter with NDA | Cover Letter(s) | 2017-11-23 | PDF 563.3 KB |
| label letter | Cover Letter(s) | 2017-11-23 | PDF 230.4 KB |
| RF exposure info | RF Exposure Info | 2025-09-22 | PDF 18.6 KB |
| MPE | RF Exposure Info | 2017-11-23 | PDF 37 KB |
| Users Manual Metadata only | Users Manual | PDF 5.1 MB | |
| user manual Metadata only | Users Manual | PDF 5.3 MB | |
| internal photos Metadata only | Internal Photos | PDF 1.1 MB | |
| block diagram Metadata only | Block Diagram | PDF 233.6 KB | |
| schematics Metadata only | Schematics | PDF 1.5 MB | |
| Operational Description Metadata only | Operational Description | PDF 277.4 KB | |
| operational description Metadata only | Operational Description | PDF 395.6 KB | |
| Tune up info Metadata only | Parts List/Tune Up Info | PDF 169.6 KB | |
| parts list Metadata only | Parts List/Tune Up Info | PDF 346.9 KB | |
| tune up information Metadata only | Parts List/Tune Up Info | PDF 230.3 KB |
Application Information
| Application ID | xlDp54hqe6q09KWItm/zoQ== |
|---|---|
| Final Action Date | 2025-09-22 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0018963462 |
| Model | MP6B |
| Frequency Range | 758-768 MHz |
| Equipment Class | B9B - Part 90 Class B Industrial Booster (non-SMR) |
| Device Description | Remote Unit Medium Power |
| Responsible Party | Alessandro Brunelli, abrunelli@jmawireless.com |
| Test Firm | Roberto Giampaglia, Nemko S.p.A., segreteria@nemko.com |
| TCB Email | jin.xu@nemko.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| xlDp54hqe6q09KWItm/zoQ== | 2025-09-22 | Class II permissive change or modification of presently authorized equipment |
| ryBqpXacucr4TTyXLH4Hgg== | 2025-09-22 | Class II permissive change or modification of presently authorized equipment |
| lau98iHwrVWH6BYYi5XXLg== | 2017-11-23 | Original Equipment |
| L+2ANychrG8lSB7TFYuctQ== | 2017-11-23 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 758-768 MHz | 2.0000000 | Amp | D7W | 90 | PF |
| 858.5-869 MHz | 2 | Amp | F9W | 90S | |
| 858.5-869 MHz | 2 | Amp | GXW | 90S | |
| 858.5-869 MHz | 2 | Amp | D7W | 90S | |
| 869-894 MHz | 2 | Amp | F9W | 22H | |
| 869-894 MHz | 2 | Amp | GXW | 22H | |
| 869-894 MHz | 2 | Amp | D7W | 22H | |
| 1930-1995 MHz | 2 | Amp | D7W | 24E | |
| 1930-1995 MHz | 2 | Amp | F9W | 24E | |
| 1930-1995 MHz | 2 | Amp | GXW | 24E | |
| 1995-2020 MHz | 2 | Amp | F9W | 27 | |
| 1995-2020 MHz | 2 | Amp | GXW | 27 | |
| 1995-2020 MHz | 2 | Amp | D7W | 27 | |
| 2110-2200 MHz | 2 | Amp | F9W | 27 | |
| 2110-2200 MHz | 2 | Amp | D7W | 27 | |
| 2350-2360 MHz | 2 | Amp | D7W | 27 |
Grants
TCB Grant - Application xlDp54hqe6q09KWItm/zoQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, Inc. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 09/22/2025 Application Dated: 09/19/2025 |
| JMA Innovazione S.r.l. a socio unico |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-MP6B |
| Name of Grantee: | JMA Innovazione S.r.l. a socio unico |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit Medium Power |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 758.0 - 768.0 | 2.0 | Amp | D7W |
| C2PC as described in this filing. Power output listed is conducted and is the composite for multi-channel operation. This equipment supports GSM/EDGE, CDMA/W-CDMA, LTE and 5G NR modulations. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
| PF: | Transmitter approved for Public Safety Broadband |
TCB Grant - Application ryBqpXacucr4TTyXLH4Hgg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, Inc. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 09/22/2025 Application Dated: 09/19/2025 |
| JMA Innovazione S.r.l. a socio unico |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-MP6B |
| Name of Grantee: | JMA Innovazione S.r.l. a socio unico |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit Medium Power |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 728.0 - 758.0 | 2.0 | Amp | D7W | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | F9W | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | GXW | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | D7W | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | GXW | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | D7W | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | F9W | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | GXW | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | D7W | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | F9W | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | GXW | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | D7W | |
| 27 | 2110.0 - 2200.0 | 2.0 | Amp | F9W | |
| 27 | 2110.0 - 2200.0 | 2.0 | Amp | D7W | |
| 27 | 2350.0 - 2360.0 | 2.0 | Amp | D7W |
| C2PC as described in this filing. Power output listed is conducted and is the composite for multi-channel operation. This equipment supports GSM/EDGE, CDMA/W-CDMA, LTE and 5G NR modulations. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47.
|
TCB Grant - Application lau98iHwrVWH6BYYi5XXLg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 11/23/2017 Application Dated: 11/22/2017 |
| Teko Telecom Srl |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-MP6B |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit Medium Power |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 728.0 - 758.0 | 2.0 | Amp | D7W | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | F9W | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | GXW | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | D7W | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | GXW | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | D7W | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | F9W | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | GXW | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | D7W | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | F9W | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | GXW | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | D7W | |
| 27 | 2110.0 - 2200.0 | 2.0 | Amp | F9W | |
| 27 | 2110.0 - 2200.0 | 2.0 | Amp | D7W | |
| 27 | 2350.0 - 2360.0 | 2.0 | Amp | D7W |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47. |
EAS Grant - Application lau98iHwrVWH6BYYi5XXLg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Teko Telecom Srl Via Meucci 24/A Castel San Pietro Terme BO, 40024 Italy |
Date of Grant: 11/23/2017 Application Dated: 11/22/2017 |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-MP6B |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit Medium Power |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 728.0 - 758.0 | 2.0 | Amp | D7W | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | F9W | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | GXW | |
| 90S | 858.5 - 869.0 | 2.0 | Amp | D7W | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | GXW | |
| 22H | 869.0 - 894.0 | 2.0 | Amp | D7W | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | F9W | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | GXW | |
| 24E | 1930.0 - 1995.0 | 2.0 | Amp | D7W | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | F9W | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | GXW | |
| 27 | 1995.0 - 2020.0 | 2.0 | Amp | D7W | |
| 27 | 2110.0 - 2200.0 | 2.0 | Amp | F9W | |
| 27 | 2110.0 - 2200.0 | 2.0 | Amp | D7W | |
| 27 | 2350.0 - 2360.0 | 2.0 | Amp | D7W |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 11/23/2017 Application Dated: 11/22/2017 |
| Teko Telecom Srl |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-MP6B |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit Medium Power |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 758.0 - 768.0 | 2.0 | Amp | D7W |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
| PF: | Transmitter approved for Public Safety Broadband |
EAS Grant - Application L+2ANychrG8lSB7TFYuctQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Teko Telecom Srl Via Meucci 24/A Castel San Pietro Terme BO, 40024 Italy |
Date of Grant: 11/23/2017 Application Dated: 11/22/2017 |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-MP6B |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 90 Class B Industrial Booster (non-SMR) |
| Notes: | Remote Unit Medium Power |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| PF | 90 | 758.0 - 768.0 | 2.0 | Amp | D7W |
| Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). |
| PF: | Transmitter approved for Public Safety Broadband |
| Mail To: |