FCC ID XM2-MP7FL8P9PP

Remote Unit Medium Power

by Teko Telecom Srl

Grantee Code: XM2   Product Code: MP7FL8P9PP
Latest application date: 2019-07-18

FCC ID Device Details

FCC IDXM2-MP7FL8P9PP
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXM2
Product CodeMP7FL8P9PP
Applicant BusinessTeko Telecom Srl 🇮🇹
Related Domains jmawireless.com
Equipment ClassRemote Unit Medium Power
Test FirmNemko S.p.A.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
928-929 MHzOriginal Equipment2019-07-18
929-930 MHzOriginal Equipment2019-07-18
758-768 MHzOriginal Equipment2019-07-18

Exhibits

DocumentTypeAvailableFile
external photosExternal Photos2019-07-18PDF 519.9 KB
labelID Label/Location Info2019-07-18PDF 214.4 KB
label locationID Label/Location Info2019-07-18PDF 393 KB
372837-10TRFWL [940-941 MHz]Test Report2019-07-18PDF 2.3 MB
372837-1TRFWL [758-768 MHz]Test Report2019-07-18PDF 2.6 MB
372837-2TRFWL [769-775 MHz]Test Report2019-07-18PDF 2.2 MB
372837-3TRFWL [851-862 MHz]Test Report2019-07-18PDF 2.9 MB
372837-4TRFWL [928-929 MHz]Test Report2019-07-18PDF 3.3 MB
372837-5TRFWL [929-930 MHz]Test Report2019-07-18PDF 2.7 MB
372837-6TRFWL [930-931 MHz]Test Report2019-07-18PDF 2.2 MB
372837-7TRFWL [931-932 MHz]Test Report2019-07-18PDF 3.2 MB
372837-8TRFWL [932-935 MHz]Test Report2019-07-18PDF 3.3 MB
372837-9TRFWL [935-940 MHz]Test Report2019-07-18PDF 2.7 MB
agent letterCover Letter(s)2019-07-18PDF 195.2 KB
confidential letterCover Letter(s)2019-07-18PDF 291 KB
warning label letterCover Letter(s)2019-07-18PDF 148.7 KB
MPERF Exposure Info2019-07-18PDF 29.8 KB
user manual Metadata onlyUsers ManualPDF 4.9 MB
internal photos Metadata onlyInternal PhotosPDF 628.5 KB
block diagram Metadata onlyBlock DiagramPDF 153.6 KB
schematics Metadata onlySchematicsPDF 974.5 KB
operational description Metadata onlyOperational DescriptionPDF 213.8 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 184 KB
tune up procedure Metadata onlyParts List/Tune Up InfoPDF 148.6 KB

Application Information

Application IDuV73Sz1UxjLLqZ+3Ve3slA==
Final Action Date2019-07-18
Application PurposeOriginal Equipment
Applicant FRN0018963462
ModelMP7FL8P9PP
Frequency Range928-929 MHz
Equipment ClassBOS - All other signal boosters other than 20.21/90.219
Device DescriptionRemote Unit Medium Power
Responsible PartyAlessandro Brunelli, Certification Engineer, abrunelli@jmawireless.com , +39 051 6946811
Test FirmRoberto Giampaglia, Nemko S.p.A., segreteria@nemko.com , +39 039 220 12 01
TCB Emailstuart.beck@nemko.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
uV73Sz1UxjLLqZ+3Ve3slA==2019-07-18Original Equipment
QrTJnouMiave1kSfJfKoiQ==2019-07-18Original Equipment
6sJJOzHvA9tHQYRPx/ccJA==2019-07-18Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
769-775 MHz2AmpF1E9
769-775 MHz2AmpF1D9
769-775 MHz2AmpF3E9
851-862 MHz2AmpF1E9
851-862 MHz2AmpF1D9
851-862 MHz2AmpF3E9
928-929 MHz2AmpF1E101
928-929 MHz2AmpF1D101
928-929 MHz2AmpF3E101
929-930 MHz2AmpF3E9
929-930 MHz2AmpF1D22
929-930 MHz2AmpF3E22
929-930 MHz2AmpF1E9
929-930 MHz2AmpF1D9
930-931 MHz2AmpD7W24D
931-932 MHz2AmpF1E22
931-932 MHz2AmpF1D22
931-932 MHz2AmpF3E22
932-935 MHz2AmpF1E101
932-935 MHz2AmpF1D101
932-935 MHz2AmpF3E101
935-940 MHz2AmpF3E90S
935-940 MHz2AmpF1E9
935-940 MHz2AmpF1D9
935-940 MHz2AmpF3E9
935-940 MHz2AmpF1E90S
935-940 MHz2AmpF1D90S
940-941 MHz2AmpD7W24D

Grants

TCB Grant - Application uV73Sz1UxjLLqZ+3Ve3slA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 07/18/2019

Application Dated: 07/18/2019
Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP7FL8P9PP
Name of Grantee:  Teko Telecom Srl
Equipment Class: All other signal boosters other than 20.21/90.219
Notes: Remote Unit Medium Power
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
101 928.0  -  929.0 2.0  Amp F1E
101 928.0  -  929.0 2.0  Amp F1D
101 928.0  -  929.0 2.0  Amp F3E
101 932.0  -  935.0 2.0  Amp F1E
101 932.0  -  935.0 2.0  Amp F1D
101 932.0  -  935.0 2.0  Amp F3E

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of §1.1307(b)(3).

EAS Grant - Application uV73Sz1UxjLLqZ+3Ve3slA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
  Date of Grant: 07/18/2019

Application Dated: 07/18/2019
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP7FL8P9PP
Name of Grantee:  Teko Telecom Srl
Equipment Class: All other signal boosters other than 20.21/90.219
Notes: Remote Unit Medium Power
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
101 928.0  -  929.0 2.0  Amp F1E
101 928.0  -  929.0 2.0  Amp F1D
101 928.0  -  929.0 2.0  Amp F3E
101 932.0  -  935.0 2.0  Amp F1E
101 932.0  -  935.0 2.0  Amp F1D
101 932.0  -  935.0 2.0  Amp F3E

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of §1.1307(b)(3).



TCB Grant - Application QrTJnouMiave1kSfJfKoiQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 07/18/2019

Application Dated: 07/18/2019
Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP7FL8P9PP
Name of Grantee:  Teko Telecom Srl
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Remote Unit Medium Power
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22 929.0  -  930.0 2.0  Amp F1E
22 929.0  -  930.0 2.0  Amp F1D
22 929.0  -  930.0 2.0  Amp F3E
24D 930.0  -  931.0 2.0  Amp D7W
22 931.0  -  932.0 2.0  Amp F1E
22 931.0  -  932.0 2.0  Amp F1D
22 931.0  -  932.0 2.0  Amp F3E
90S 935.0  -  940.0 2.0  Amp F1E
90S 935.0  -  940.0 2.0  Amp F1D
90S 935.0  -  940.0 2.0  Amp F3E
24D 940.0  -  941.0 2.0  Amp D7W

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of §1.1307(b)(3).

EAS Grant - Application QrTJnouMiave1kSfJfKoiQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
  Date of Grant: 07/18/2019

Application Dated: 07/18/2019
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP7FL8P9PP
Name of Grantee:  Teko Telecom Srl
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Remote Unit Medium Power
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22 929.0  -  930.0 2.0  Amp F1E
22 929.0  -  930.0 2.0  Amp F1D
22 929.0  -  930.0 2.0  Amp F3E
24D 930.0  -  931.0 2.0  Amp D7W
22 931.0  -  932.0 2.0  Amp F1E
22 931.0  -  932.0 2.0  Amp F1D
22 931.0  -  932.0 2.0  Amp F3E
90S 935.0  -  940.0 2.0  Amp F1E
90S 935.0  -  940.0 2.0  Amp F1D
90S 935.0  -  940.0 2.0  Amp F3E
24D 940.0  -  941.0 2.0  Amp D7W

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of §1.1307(b)(3).



TCB Grant - Application 6sJJOzHvA9tHQYRPx/ccJA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, INC.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 07/18/2019

Application Dated: 07/18/2019
Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP7FL8P9PP
Name of Grantee:  Teko Telecom Srl
Equipment Class: Part 90 Class B Industrial Booster (non-SMR)
Notes: Remote Unit Medium Power
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
PF 90 758.0  -  768.0 2.0  Amp D7W
90 769.0  -  775.0 2.0  Amp F1E
90 769.0  -  775.0 2.0  Amp F1D
90 769.0  -  775.0 2.0  Amp F3E
90 851.0  -  862.0 2.0  Amp F1E
90 851.0  -  862.0 2.0  Amp F1D
90 851.0  -  862.0 2.0  Amp F3E
90 929.0  -  930.0 2.0  Amp F1E
90 929.0  -  930.0 2.0  Amp F1D
90 929.0  -  930.0 2.0  Amp F3E
90 935.0  -  940.0 2.0  Amp F1E
90 935.0  -  940.0 2.0  Amp F1D
90 935.0  -  940.0 2.0  Amp F3E

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of §1.1307(b)(3).

PF: Transmitter approved for Public Safety Broadband

EAS Grant - Application 6sJJOzHvA9tHQYRPx/ccJA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
  Date of Grant: 07/18/2019

Application Dated: 07/18/2019
 
Attention: Alessandro Brunelli , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XM2-MP7FL8P9PP
Name of Grantee:  Teko Telecom Srl
Equipment Class: Part 90 Class B Industrial Booster (non-SMR)
Notes: Remote Unit Medium Power
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
PF 90 758.0  -  768.0 2.0  Amp D7W
90 769.0  -  775.0 2.0  Amp F1E
90 769.0  -  775.0 2.0  Amp F1D
90 769.0  -  775.0 2.0  Amp F3E
90 851.0  -  862.0 2.0  Amp F1E
90 851.0  -  862.0 2.0  Amp F1D
90 851.0  -  862.0 2.0  Amp F3E
90 929.0  -  930.0 2.0  Amp F1E
90 929.0  -  930.0 2.0  Amp F1D
90 929.0  -  930.0 2.0  Amp F3E
90 935.0  -  940.0 2.0  Amp F1E
90 935.0  -  940.0 2.0  Amp F1D
90 935.0  -  940.0 2.0  Amp F3E

Power output listed is conducted and is the composite for multi-channel operation. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of §1.1307(b)(3).


PF: Transmitter approved for Public Safety Broadband

Mail To: