Remote Unit Enhanced Power
by Teko Telecom Srl
Grantee Code: XM2 Product Code: WHPA19HN
Latest application date: 2024-02-02
FCC ID Device Details
| FCC ID | XM2-WHPA19HN |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XM2 |
| Product Code | WHPA19HN |
| Applicant Business | Teko Telecom Srl 🇮🇹 |
| Related Domains | |
| Equipment Class | Remote Unit Enhanced Power |
| Test Firm | Nemko S.p.A. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1930-1995 MHz | Class II permissive change or modification of presently authorized equipment | 2024-02-02 |
| 1930-1995 MHz | Original Equipment | 2020-08-05 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2024-02-02 | PDF 346.9 KB |
| external photos | External Photos | 2020-08-05 | PDF 346.9 KB |
| Label and Label Location | ID Label/Location Info | 2024-02-02 | PDF 360.1 KB |
| label | ID Label/Location Info | 2020-08-05 | PDF 152.3 KB |
| label and location | ID Label/Location Info | 2020-08-05 | PDF 360.1 KB |
| Test Setup Photos | Test Setup Photos | 2024-02-02 | PDF 437.8 KB |
| Test Report | Test Report | 2024-02-02 | PDF 1.9 MB |
| test report 1930 - 1995 MHz | Test Report | 2020-08-05 | PDF 2.6 MB |
| test report 1995 - 2020 | Test Report | 2020-08-05 | PDF 2.6 MB |
| Attestation statement | Attestation Statements | 2024-02-02 | PDF 399.5 KB |
| Attestation statement | Attestation Statements | 2024-02-02 | PDF 146.5 KB |
| Cover Letters | Cover Letter(s) | 2024-02-02 | PDF 498.6 KB |
| Cover Letters | Cover Letter(s) | 2024-02-02 | PDF 422.6 KB |
| agent letter | Cover Letter(s) | 2020-08-05 | PDF 194.8 KB |
| confidential letter | Cover Letter(s) | 2020-08-05 | PDF 298.7 KB |
| label letter | Cover Letter(s) | 2020-08-05 | PDF 148.4 KB |
| RF Exposure info | RF Exposure Info | 2024-02-02 | PDF 29.2 KB |
| RF Exposure info | RF Exposure Info | 2024-02-02 | PDF 29.2 KB |
| MPE | RF Exposure Info | 2020-08-05 | PDF 29.2 KB |
| MPE MIMO | RF Exposure Info | 2020-08-05 | PDF 29.2 KB |
| Users Manual Metadata only | Users Manual | PDF 4.3 MB | |
| user manual Metadata only | Users Manual | PDF 4.9 MB | |
| internal photos Metadata only | Internal Photos | PDF 696 KB | |
| block diagram Metadata only | Block Diagram | PDF 202.9 KB | |
| schematics 05a Metadata only | Schematics | PDF 283.6 KB | |
| schematics 05b Metadata only | Schematics | PDF 44.2 KB | |
| operational description Metadata only | Operational Description | PDF 786.5 KB | |
| Tune up info Metadata only | Parts List/Tune Up Info | PDF 360.5 KB | |
| parts list 06a Metadata only | Parts List/Tune Up Info | PDF 129.3 KB | |
| parts list 06b Metadata only | Parts List/Tune Up Info | PDF 89.7 KB | |
| tune up information Metadata only | Parts List/Tune Up Info | PDF 148.4 KB |
Application Information
| Application ID | 7aIbbaNnW84qrLvoJRSIBg== |
|---|---|
| Final Action Date | 2024-02-02 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0018963462 |
| Model | WHPA19HN |
| Frequency Range | 1930-1995 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | Remote Unit Enhanced Power |
| Responsible Party | Alessandro Brunelli, Certification Engineer, abrunelli@jmawireless.com |
| Test Firm | Roberto Giampaglia, Nemko S.p.A., segreteria@nemko.com |
| TCB Email | jin.xu@nemko.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | C2PC as described in this filing. Power output listed is conducted per antenna port. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 7aIbbaNnW84qrLvoJRSIBg== | 2024-02-02 | Class II permissive change or modification of presently authorized equipment |
| dBEw3htnE5s/cspkUmUmBQ== | 2020-08-05 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application dBEw3htnE5s/cspkUmUmBQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 08/05/2020 Application Dated: 08/04/2020 |
| Teko Telecom Srl |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-WHPA19HN |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Very Very High Power Module Amplifier |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | F9W |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | GXW |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | D7W |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | F9W |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | GXW |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | D7W |
| Power output listed is conducted per antenna port. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application dBEw3htnE5s/cspkUmUmBQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Teko Telecom Srl Via Meucci 24/A Castel San Pietro Terme BO, 40024 Italy |
Date of Grant: 08/05/2020 Application Dated: 08/04/2020 |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-WHPA19HN |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Very Very High Power Module Amplifier |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | F9W |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | GXW |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | D7W |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | F9W |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | GXW |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | D7W |
| Power output listed is conducted per antenna port. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, Inc. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 02/02/2024 Application Dated: 02/02/2024 |
| Teko Telecom Srl |
| Via Meucci 24/A |
| Castel San Pietro Terme BO, 40024 Italy |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-WHPA19HN |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit Enhanced Power |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | F9W |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | GXW |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | D7W |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | F9W |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | GXW |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | D7W |
| C2PC as described in this filing. Power output listed is conducted per antenna port. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application 7aIbbaNnW84qrLvoJRSIBg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Teko Telecom Srl Via Meucci 24/A Castel San Pietro Terme BO, 40024 Italy |
Date of Grant: 02/02/2024 Application Dated: 02/02/2024 |
| Attention: Alessandro Brunelli , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XM2-WHPA19HN |
| Name of Grantee: | Teko Telecom Srl |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Remote Unit Enhanced Power |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | F9W |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | GXW |
| MO | 24E | 1930.0 - 1995.0 | 40.0 | Amp | D7W |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | F9W |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | GXW |
| MO | 27 | 1995.0 - 2020.0 | 40.0 | Amp | D7W |
| C2PC as described in this filing. Power output listed is conducted per antenna port. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures with a separation distance from all persons during normal operation as documented in this filing. RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This equipment is authorized for operating at stations qualified under the conditions of FCC DA 13-2409 (1995-2000 MHz downlink transmissions are allowed at sites also having downlink transmissions in 2000-2020 MHz that are in accordance with all rules specified in DA 13-2409 at 47. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |