Teko Telecom Srl Enhanced Power Remote Unit for Optical system booster EP2325
An FCC ID is the product ID assigned by the FCC to identify wireless products in the market. The FCC chooses 3 or 5 character "Grantee" codes to identify the business that created the product.
For example, the grantee code for FCC ID: XM2-EP2325 is XM2. The remaining characters of the FCC ID, -EP2325, are often associated with the product model, but they can be random. These letters are chosen by the applicant.
In addition to the application, the FCC also publishes internal images, external images, user manuals, and test results for wireless devices. They can be under the "exhibits" tab below.
Application for Equipment Authorization FCC Form 731 TCB Version
WILLFUL FALSE STATEMENTS MADE ON THIS FORM ARE PUNISHABLE BY FINE AND IMPRISONMENT
(U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR
CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1)), AND/OR FORFEITURE
(U.S. CODE, TITLE 47, SECTION 503).
Applications are submitted for FCC ID and Grant requests. Click an above application to view details
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for
the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
FCC IDENTIFIER:
XM2-EP2325
Name of Grantee:
Teko Telecom Srl
Equipment Class:
Part 20 Industrial Booster (CMRS)
Notes:
Enhanced Power Remote Unit for Optical system booster
Grant Notes
FCC Rule Parts
Frequency Range (MHZ)
Output Watts
Frequency Tolerance
Emission Designator
27
2350.0
-
2360.0
1.25
Amp
D7W
27
2496.0
-
2690.0
1.25
Amp
D7W
Power output listed is the composite for multi-channel operation. This transmitter operates as a remote unit as part of a system along with host/master unit components as described in this filing and excluding any other devices connected to the (uplink) output terminal of the master unit. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Antennas installed for each remote unit must provide a minimum 100 cm separation distance from all persons as described in this filing. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance, including antenna co-location requirements of 1.1307(b)(3). RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s).
COPY
FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554
GRANT OF EQUIPMENT AUTHORIZATION
COPY
Certification
Teko Telecom Srl
Via Meucci 24/A
Castel San Pietro Terme BO, 40024
Italy
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for
the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
FCC IDENTIFIER:
XM2-EP2325
Name of Grantee:
Teko Telecom Srl
Equipment Class:
Part 20 Industrial Booster (CMRS)
Notes:
Enhanced Power Remote Unit for Optical system booster
Modular Type:
Does not apply
Grant Notes
FCC Rule Parts
Frequency Range (MHZ)
Output Watts
Frequency Tolerance
Emission Designator
27
2350.0
-
2360.0
1.25
Amp
D7W
27
2496.0
-
2690.0
1.25
Amp
D7W
Power output listed is the composite for multi-channel operation. This transmitter operates as a remote unit as part of a system along with host/master unit components as described in this filing and excluding any other devices connected to the (uplink) output terminal of the master unit. This application covers only the system configuration with host/master unit connected to a base station in the uplink path; operations if any with host/master unit connected to antenna or amplifier in the uplink require separate equipment authorization. This filing has compliance demonstration information and test data only for SISO (single-input single-output) booster system configurations; additional equipment authorization is required to allow this device to be used in MIMO (multiple-input multiple-output) industrial booster systems. Antennas installed for each remote unit must provide a minimum 100 cm separation distance from all persons as described in this filing. The antenna(s) used for this transmitter must be fixed-mounted on outdoor/indoor permanent structures. Users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance, including antenna co-location requirements of 1.1307(b)(3). RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s).