FCC ID XMHQP-350-U2
TWO-WAY RADIO
by Quantun Electronics, LLC
Grantee Code: XMH Product Code: QP350U2
Latest application date: 2011-09-12
FCC ID Device Details
| FCC ID | XMHQP-350-U2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XMH |
| Product Code | QP350U2 |
| Applicant Business | Quantun Electronics, LLC 🇺🇸 |
| Equipment Class | TWO-WAY RADIO |
| Test Firm | Bontek Compliance Testing Laboratory Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 450-470 MHz | Original Equipment | 2011-09-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2011-09-12 | PDF 469.3 KB |
| Internal Photos | Internal Photos | 2011-09-12 | PDF 133.4 KB |
| External Photos | External Photos | 2011-09-12 | PDF 51.3 KB |
| Label Info | ID Label/Location Info | 2011-09-12 | PDF 62.9 KB |
| Block Diagram | Block Diagram | 2011-09-12 | PDF 40 KB |
| Parts List | Parts List/Tune Up Info | 2011-09-12 | PDF 165.8 KB |
| Schematics | Schematics | 2011-09-12 | PDF 165.8 KB |
| Theory of Operation | Operational Description | 2011-09-12 | PDF 23.1 KB |
| Test Setup Photos | Test Setup Photos | 2011-09-12 | PDF 60.6 KB |
| Test Report | Test Report | 2011-09-12 | PDF 1.2 MB |
| Justification Letter | Cover Letter(s) | 2011-09-12 | PDF 104.3 KB |
| POA | Cover Letter(s) | 2011-09-12 | PDF 54.6 KB |
| SAR Report | RF Exposure Info | 2011-09-12 | PDF 3.3 MB |
| Tune up Procedure | Parts List/Tune Up Info | 2011-09-12 | PDF 137.4 KB |
Application Information
| Application ID | cuFlOqlH9vZlV46/ivBvZg== |
|---|---|
| Final Action Date | 2011-09-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0018979062 |
| Model | QP-350-U2 |
| Frequency Range | 450-470 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | TWO-WAY RADIO |
| Responsible Party | Francisco Noyola, CEO, 229044961@qq.com |
| Test Firm | Tony Wu, Bontek Compliance Testing Laboratory Ltd, tony@bontek.com.cn |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. Maximum conducted output power is 2.4W according to 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1.8 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels for Head and Body-Worn accessories are 1.36 W/kg and 3.15 W/kg respectively for a 50% Duty Cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| cuFlOqlH9vZlV46/ivBvZg== | 2011-09-12 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application cuFlOqlH9vZlV46/ivBvZg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 <BR>P.O. Box 370, Newberry, FL 32669 |
Date of Grant: 09/12/2011 Application Dated: 09/12/2011 |
| Quantun Electronics, LLC |
| 14005 NW 8 Street Unit 2 |
| Sunrise, FL 33323 |
| Attention: Francisco Noyola , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XMHQP-350-U2 |
| Name of Grantee: | Quantun Electronics, LLC |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | TWO-WAY RADIO |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 470.0 | 2.0 | 1.1 PM | 11K0F3E |
| Power listed is conducted. Maximum conducted output power is 2.4W according to 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1.8 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels for Head and Body-Worn accessories are 1.36 W/kg and 3.15 W/kg respectively for a 50% Duty Cycle. |
EAS Grant - Application cuFlOqlH9vZlV46/ivBvZg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Quantun Electronics, LLC 14005 NW 8 Street Unit 2 Sunrise, FL 33323 United States |
Date of Grant: 09/12/2011 Application Dated: 09/12/2011 |
| Attention: Francisco Noyola , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XMHQP-350-U2 |
| Name of Grantee: | Quantun Electronics, LLC |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | TWO-WAY RADIO |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 450.0 - 470.0 | 2.0 | 1.1 PM | 11K0F3E |
| Power listed is conducted. Maximum conducted output power is 2.4W according to 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1.8 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels for Head and Body-Worn accessories are 1.36 W/kg and 3.15 W/kg respectively for a 50% Duty Cycle. |
| Mail To: |