FCC ID XN3-Q1000-25
Quantum 1000 Base Station
by Mercury Networks, LLC
Grantee Code: XN3 Product Code: Q100025
Latest application date: 2010-02-05
FCC ID Device Details
| FCC ID | XN3-Q1000-25 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XN3 |
| Product Code | Q100025 |
| Applicant Business | Mercury Networks, LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | Quantum 1000 Base Station |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2501-2685 MHz | Original Equipment | 2010-02-05 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2010-02-05 | PDF 4.9 MB |
| Internal Photos | Internal Photos | 2010-02-05 | PDF 2 MB |
| External Photos | External Photos | 2010-02-05 | PDF 424.6 KB |
| ID Label | ID Label/Location Info | 2010-02-05 | PDF 218.8 KB |
| Test Report | Test Report | 2010-02-05 | PDF 1.1 MB |
| Confidentiality request | Cover Letter(s) | 2010-02-05 | PDF 92.4 KB |
| RF Exposure | RF Exposure Info | 2010-02-05 | PDF 10 KB |
Application Information
| Application ID | x1V6WOYzC1PuBxldeJ9etg== |
|---|---|
| Final Action Date | 2010-02-05 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0023660863 |
| Model | -Q1000-25 |
| Frequency Range | 2501-2685 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | Quantum 1000 Base Station |
| Responsible Party | Garrett Wiseman, President, garrett.wiseman@mercurywireless.com |
| Agent | Yuriy Yuriy Yuriy, Intertek, yuriy.litvinov@intertek.com |
| Technical Contact | Ollie Moyrong, Intertek, ollie.moyrong@intertek.com |
| TCB Email | tcb_admin@intertek.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted per antenna terminal. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b) (3). The installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This grant is issued subject to the condition that the transmitter can operate at the channel bandwidth as indicated in the filing. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| x1V6WOYzC1PuBxldeJ9etg== | 2010-02-05 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application x1V6WOYzC1PuBxldeJ9etg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Intertek Testing Services NA, Inc. 70 Codman Hill Road Boxborough, MA 01719 |
Date of Grant: 02/05/2010 Application Dated: 02/05/2010 |
| Mercury Networks, LLC |
| 6714 Pointe Inverness Way |
| Suite 230 |
| Fort Wayne, IN 46804 |
| Attention: Garrett Wiseman , President |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XN3-Q1000-25 |
| Name of Grantee: | Mercury Networks, LLC |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Quantum 1000 Base Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 2501.0 - 2685.0 | 4.07 | 0.016 PM | 9M39DXW |
| Power listed is conducted per antenna terminal. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b) (3). The installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This grant is issued subject to the condition that the transmitter can operate at the channel bandwidth as indicated in the filing. |
EAS Grant - Application x1V6WOYzC1PuBxldeJ9etg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Mercury Networks, LLC 6714 Pointe Inverness Way Suite 230 Fort Wayne, IN 46804 United States |
Date of Grant: 02/05/2010 Application Dated: 02/05/2010 |
| Attention: Garrett Wiseman , President |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XN3-Q1000-25 |
| Name of Grantee: | Mercury Networks, LLC |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Quantum 1000 Base Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 2501.0 - 2685.0 | 4.07 | 0.016 PM | 9M39DXW |
| Power listed is conducted per antenna terminal. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b) (3). The installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This grant is issued subject to the condition that the transmitter can operate at the channel bandwidth as indicated in the filing. |
| Mail To: |