FCC ID XNL-ORTHOSNSR1

"Sensor Assisted Surgical" (SAS™) Device

by Orthosensor, Inc

Grantee Code: XNL   Product Code: ORTHOSNSR1
Latest application date: 2011-12-16

FCC ID Device Details

FCC IDXNL-ORTHOSNSR1
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXNL
Product CodeORTHOSNSR1
Applicant BusinessOrthosensor, Inc 🇺🇸
Related Domains orthosensor.com compliancetesting.com
Equipment Class"Sensor Assisted Surgical" (SAS™) Device
Test FirmCompliance Testing, LLC

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
402-405 MHzOriginal Equipment2011-12-16

Exhibits

DocumentTypeAvailableFile
User's Manual DraftUsers Manual2011-12-16PDF 145 KB
Internal PhotosInternal Photos2011-12-16PDF 487.8 KB
Internal Photos with UNIInternal Photos2011-12-16PDF 488.7 KB
External PhotosExternal Photos2011-12-16PDF 257 KB
External Photos with UNIExternal Photos2011-12-16PDF 1.5 MB
Label and LocationID Label/Location Info2011-12-16PDF 403 KB
Test Setup PhotosTest Setup Photos2011-12-16PDF 180.5 KB
FCC Part 95 Test ReportTest Report2011-12-16PDF 510 KB
CT Response to FCC QuestionsCover Letter(s)2011-12-16PDF 86.4 KB
FCC Agent Authorization LetterCover Letter(s)2011-12-16PDF 134.8 KB
FCC Confidentiality LetterCover Letter(s)2011-12-16PDF 51.6 KB
OrthoSensor PADT Relationship LetterCover Letter(s)2011-12-16PDF 42.1 KB
Response LetterCover Letter(s)2011-12-16PDF 52.5 KB
S4-Final SAR ReportRF Exposure Info2011-12-16PDF 463 KB
Uni-Final SAR ReportRF Exposure Info2011-12-16PDF 393 KB

Application Information

Application ID8FdMvbEsvZPrW25O+9feuw==
Final Action Date2011-12-16
Application PurposeOriginal Equipment
Applicant FRN0019007368
Model-ORTHOSNSR1
Frequency Range402-405 MHz
Equipment ClassTNT - Licensed Non-Broadcast Transmitter Worn on Body
Device Description"Sensor Assisted Surgical" (SAS™) Device
Responsible PartyJuan C Fernandez, Chief Operating Officer, jfernandez@orthosensor.com , (954) 577-7770
AgentKaren Karen Karen, Compliance Testing, karens@compliancetesting.com , (480) 926-3100
Technical ContactJohn Erhard, Compliance Testing, johne@compliancetesting.com , (480) 926-3100
Non-Technical ContactKaren Springer, Compliance Testing, karens@compliancetesting.com , (480) 926-3100
Test FirmMichael Schafer, Compliance Testing, LLC, michaels@compliancetesting.com , 480-926-3100
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsHighest reported measured output power is 0.00000000183 W EIRP.

Applications

Application IDDatePurpose
8FdMvbEsvZPrW25O+9feuw==2011-12-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
402-405 MHz0.0000000100.0000000000ppm238KF1D95IIT

Grants

TCB Grant - Application 8FdMvbEsvZPrW25O+9feuw==

This application does not exist.

EAS Grant - Application 8FdMvbEsvZPrW25O+9feuw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Orthosensor, Inc
1855 Griffin Road Suite A-310
Dania Beach, FL 33004-2200
United States
  Date of Grant: 12/16/2011

Application Dated: 09/28/2011
 
Attention: Deborah Johnson , Regulatory Affairs Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XNL-ORTHOSNSR1
Name of Grantee:  Orthosensor, Inc
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: "Sensor Assisted Surgical" (SAS™) Device
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
IT 95I 402.0  -  405.0 0E-7 100.0  PM 238KF1D

Highest reported measured output power is 0.00000000183 W EIRP.


IT: Implanted Transmitter

Mail To: