FCC ID XOH-GSM001
Mobile Cellular / PCS GSM Transceiver Module
by Medtronic Monitoring, Inc.
Grantee Code: XOH Product Code: GSM001
Latest application date: 2010-11-30
FCC ID Device Details
| FCC ID | XOH-GSM001 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XOH |
| Product Code | GSM001 |
| Applicant Business | Medtronic Monitoring, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | Mobile Cellular / PCS GSM Transceiver Module |
| Test Firm | Hermon Laboratories Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Class II permissive change or modification of presently authorized equipment | 2010-11-30 |
| 824.2-848.8 MHz | Change in identification of presently authorized equipment. Original FCC ID: IHDT56FV1 Grant Date: 12/21/2005 | 2010-06-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual for Specific Host Revised | Users Manual | 2010-11-30 | PDF 218.8 KB |
| External Photos | External Photos | 2010-06-17 | PDF 133.6 KB |
| Host Label Location | ID Label/Location Info | 2010-11-30 | PDF 220.5 KB |
| Sample Label for HOST Device | ID Label/Location Info | 2010-11-30 | PDF 10.8 KB |
| Label Info | ID Label/Location Info | 2010-06-17 | PDF 133.6 KB |
| Test Setup Photos | Test Setup Photos | 2010-11-30 | PDF 436 KB |
| Agent Letter | Cover Letter(s) | 2010-11-30 | PDF 23.2 KB |
| PC Cover Letter | Cover Letter(s) | 2010-11-30 | PDF 19.6 KB |
| Cover Letter Revised | Cover Letter(s) | 2010-06-17 | PDF 37.7 KB |
| Additional SAR Data - Appendix A | RF Exposure Info | 2010-11-30 | PDF 83.2 KB |
| Additional SAR Data - Appendix B | RF Exposure Info | 2010-11-30 | PDF 317.4 KB |
| Additional SAR Data - Appendix D - Dipole Calibration | RF Exposure Info | 2010-11-30 | PDF 629.1 KB |
| Additional SAR Data - Body Fluid Check | RF Exposure Info | 2010-11-30 | PDF 5.3 KB |
| Additional SAR Data - Data Tables | RF Exposure Info | 2010-11-30 | PDF 104.6 KB |
| SAR Report Revised | RF Exposure Info | 2010-11-30 | PDF 2.7 MB |
| Technical Review Information | RF Exposure Info | 2010-11-30 | PDF 119.1 KB |
Application Information
| Application ID | kM6EQ0h8uh8yv4OuFApFIg== |
|---|---|
| Final Action Date | 2010-11-30 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0008250839 |
| Model | -GSM001 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Mobile Cellular / PCS GSM Transceiver Module |
| Responsible Party | Charles S Farlow, Program Director, Regulatory Affairs, charles.s.farlow@medtronic.com |
| Agent | Joel Joel Joel, TUV SUD America Inc., jschneider@tuvam.com |
| Technical Contact | Joel T. Schneider, TUV SUD America Inc., jschneider@tuvam.com |
| Non-Technical Contact | Sue Rupp, TUV SUD America Inc., srupp@tuvam.com |
| Test Firm | Alexander Usoskin, Hermon Laboratories Ltd., mail@hermonlabs.com |
| TCB Email | hotline@ATCB.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. The antenna installation must provide a minimum separation distance of 20 cm from users and nearby persons and must not be colocated or operate in conjunction with any other antenna or transmitter. The combined cable loss and antenna gain must not exceed +7.55 dBi. The combined cable loss and antenna gain must not exceed +2.83 dBi and total system output must not exceed 2.0 W EIRP in the PCS band in order to comply with the EIRP limit of 24.232(b). OEM installers must be provided with antenna installation instruction and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900 MHz GSM and 1800 MHz DCS functions that are not operational in U.S. Territories. The SAR data in filings under this FCC ID is applicable to demonstrate compliance for specific portable final host products only as shown in the filings under this FCC ID. Installation of this device into other host products requires the submission of a Class II permissive change application or new application if appropriate. Body-worn SAR compliance is limited to the specific holster configurations tested for this filing. The highest reported SAR values are: Part 22 Body-worn: 0.076 W/kg; Part 24 Body-worn 0.122 W/kg This filing is only applicable for 835/ 1900 MHz GSM operations. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| kM6EQ0h8uh8yv4OuFApFIg== | 2010-11-30 | Class II permissive change or modification of presently authorized equipment |
| zZ14xZZThvOEK7iFmN1xqw== | 2010-06-17 | Change in identification of presently authorized equipment. Original FCC ID: IHDT56FV1 Grant Date: 12/21/2005 |
Equipment Authorization
Grants
TCB Grant - Application zZ14xZZThvOEK7iFmN1xqw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 06/17/2010 Application Dated: 06/17/2010 |
| Medtronic Monitoring, Inc. |
| 8200 Coral Sea Street NE |
| MVS11 |
| Mounds View, MN 55112 |
| Attention: Charles Farlow , Program Director, Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XOH-GSM001 |
| Name of Grantee: | Medtronic Monitoring, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Mobile Cellular / PCS GSM Transceiver Module |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.0 | 2.5 PM | 283KGXW | |
| 24E | 1850.2 - 1909.8 | 1.04 | 2.5 PM | 277KGXW |
| Output power listed is conducted. The antenna installation must provide a minimum separation distance of 20 cm from users and nearby persons and must not be colocated or operate in conjunction with any other antenna or transmitter. The combined cable loss and antenna gain must not exceed +7.55 dBi. The combined cable loss and antenna gain must not exceed +2.83 dBi and total system output must not exceed 2.0 W EIRP in the PCS band in order to comply with the EIRP limit of 24.232(b). OEM installers must be provided with antenna installation instruction and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900 MHz GSM and 1800 MHz DCS functions that are not operational in U.S. Territories. This filing is only applicable for 835/ 1900 MHz GSM operations. |
EAS Grant - Application zZ14xZZThvOEK7iFmN1xqw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Medtronic Monitoring, Inc. 8200 Coral Sea Street NE MVS11 Mounds View, MN 55112 United States |
Date of Grant: 06/17/2010 Application Dated: 06/17/2010 |
| Attention: Charles Farlow , Program Director, Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XOH-GSM001 |
| Name of Grantee: | Medtronic Monitoring, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Mobile Cellular / PCS GSM Transceiver Module |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.0 | 2.5 PM | 283KGXW | |
| 24E | 1850.2 - 1909.8 | 1.04 | 2.5 PM | 277KGXW |
| Output power listed is conducted. The antenna installation must provide a minimum separation distance of 20 cm from users and nearby persons and must not be colocated or operate in conjunction with any other antenna or transmitter. The combined cable loss and antenna gain must not exceed +7.55 dBi. The combined cable loss and antenna gain must not exceed +2.83 dBi and total system output must not exceed 2.0 W EIRP in the PCS band in order to comply with the EIRP limit of 24.232(b). OEM installers must be provided with antenna installation instruction and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900 MHz GSM and 1800 MHz DCS functions that are not operational in U.S. Territories. This filing is only applicable for 835/ 1900 MHz GSM operations. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 11/30/2010 Application Dated: 11/30/2010 |
| Medtronic Monitoring, Inc. |
| 8200 Coral Sea Street NE |
| MVS11 |
| Mounds View, MN 55112 |
| Attention: Charles Farlow , Program Director, Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XOH-GSM001 |
| Name of Grantee: | Medtronic Monitoring, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Mobile Cellular / PCS GSM Transceiver Module |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.0 | 2.5 PM | 283KGXW | |
| 24E | 1850.2 - 1909.8 | 1.04 | 2.5 PM | 277KGXW |
| Output power listed is conducted. The antenna installation must provide a minimum separation distance of 20 cm from users and nearby persons and must not be colocated or operate in conjunction with any other antenna or transmitter. The combined cable loss and antenna gain must not exceed +7.55 dBi. The combined cable loss and antenna gain must not exceed +2.83 dBi and total system output must not exceed 2.0 W EIRP in the PCS band in order to comply with the EIRP limit of 24.232(b). OEM installers must be provided with antenna installation instruction and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900 MHz GSM and 1800 MHz DCS functions that are not operational in U.S. Territories. The SAR data in filings under this FCC ID is applicable to demonstrate compliance for specific portable final host products only as shown in the filings under this FCC ID. Installation of this device into other host products requires the submission of a Class II permissive change application or new application if appropriate. Body-worn SAR compliance is limited to the specific holster configurations tested for this filing. The highest reported SAR values are: Part 22 Body-worn: 0.076 W/kg; Part 24 Body-worn 0.122 W/kg This filing is only applicable for 835/ 1900 MHz GSM operations. |
EAS Grant - Application kM6EQ0h8uh8yv4OuFApFIg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Medtronic Monitoring, Inc. 8200 Coral Sea Street NE MVS11 Mounds View, MN 55112 United States |
Date of Grant: 11/30/2010 Application Dated: 11/30/2010 |
| Attention: Charles Farlow , Program Director, Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XOH-GSM001 |
| Name of Grantee: | Medtronic Monitoring, Inc. |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Mobile Cellular / PCS GSM Transceiver Module |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.0 | 2.5 PM | 283KGXW | |
| 24E | 1850.2 - 1909.8 | 1.04 | 2.5 PM | 277KGXW |
| Output power listed is conducted. The antenna installation must provide a minimum separation distance of 20 cm from users and nearby persons and must not be colocated or operate in conjunction with any other antenna or transmitter. The combined cable loss and antenna gain must not exceed +7.55 dBi. The combined cable loss and antenna gain must not exceed +2.83 dBi and total system output must not exceed 2.0 W EIRP in the PCS band in order to comply with the EIRP limit of 24.232(b). OEM installers must be provided with antenna installation instruction and transmitter operating conditions for satisfying RF exposure compliance. This device contains 900 MHz GSM and 1800 MHz DCS functions that are not operational in U.S. Territories. The SAR data in filings under this FCC ID is applicable to demonstrate compliance for specific portable final host products only as shown in the filings under this FCC ID. Installation of this device into other host products requires the submission of a Class II permissive change application or new application if appropriate. Body-worn SAR compliance is limited to the specific holster configurations tested for this filing. The highest reported SAR values are: Part 22 Body-worn: 0.076 W/kg; Part 24 Body-worn 0.122 W/kg This filing is only applicable for 835/ 1900 MHz GSM operations. |
| Mail To: |