FCC ID XPB-COMAD400V3

900MHz Module

by Schlage Lock Company

Grantee Code: XPB   Product Code: COMAD400V3
Latest application date: 2022-03-11

FCC ID Device Details

FCC IDXPB-COMAD400V3
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXPB
Product CodeCOMAD400V3
Applicant BusinessSchlage Lock Company 🇺🇸
Related Domains allegion.com
Equipment Class900MHz Module
Test FirmLaird Connectivity, Inc

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
906-924 MHzOriginal Equipment2022-03-11

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2022-03-11PDF 202.8 KB
Internal PhotosInternal Photos2022-03-11PDF 512.3 KB
External PhotosExternal Photos2022-03-11PDF 865.1 KB
Label and LocationID Label/Location Info2022-03-11PDF 1.4 MB
Test Setup PhotosTest Setup Photos2022-03-11PDF 571.6 KB
Test ReportTest Report2022-03-11PDF 2.1 MB
Agent AuthorizationCover Letter(s)2022-03-11PDF 425.9 KB
Company Name Cover LetterCover Letter(s)2022-03-11PDF 174.9 KB
Confidentiality LetterCover Letter(s)2022-03-11PDF 393.1 KB
LMA Cover LetterCover Letter(s)2022-03-11PDF 355.6 KB
Modular Approval Cover LetterCover Letter(s)2022-03-11PDF 2.9 MB
Antenna Datasheet 1RF Exposure Info2022-03-11PDF 331.1 KB
Antenna Datasheet 2RF Exposure Info2022-03-11PDF 209.3 KB
Antenna Datasheet 3RF Exposure Info2022-03-11PDF 229.9 KB
Antenna Datasheet 4RF Exposure Info2022-03-11PDF 245.4 KB
Antenna Datasheet 5RF Exposure Info2022-03-11PDF 212.5 KB
RF ExposureRF Exposure Info2022-03-11PDF 783.1 KB
Block Diagram Metadata onlyBlock DiagramPDF 113.9 KB
Schematics Metadata onlySchematicsPDF 1.7 MB
Operational Description Metadata onlyOperational DescriptionPDF 94.8 KB

Application Information

Application IDYBLIhJ/ft4uEc5xv/z05Ng==
Final Action Date2022-03-11
Application PurposeOriginal Equipment
Applicant FRN0019057363
ModelCOMAD400V3
Frequency Range906-924 MHz
Equipment ClassDTS - Digital Transmission System
Device Description900MHz Module
Responsible PartyFrank Nardelli, Lead Hardware Engineer, frank.nardelli@allegion.com , 317-810-3193
Test FirmAdam Alger, Laird Connectivity, Inc, adam.alger@lairdconnect.com , 262 375 3091
TCB Emailhotline@acbcert.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentLimited Single Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsSingle Limited Modular Approval. Output power listed is conducted. This device is authorized for installation in Grantee's devices and may not be marketed to the general public. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits at the distance specified in the filing, therefore, this device may be used in mobile configurations. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. End -users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
YBLIhJ/ft4uEc5xv/z05Ng==2022-03-11Original Equipment

Equipment Authorization

FrequencyOutputRules
906-924 MHz0.102000015C

Grants

TCB Grant - Application YBLIhJ/ft4uEc5xv/z05Ng==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/11/2022

Application Dated: 03/11/2022
Schlage Lock Company
11819 N. Pennsylvania Street
Carmel, IN 46032
 
Attention: Frank Nardelli , Lead Hardware Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XPB-COMAD400V3
Name of Grantee:  Schlage Lock Company
Equipment Class: Digital Transmission System
Notes: 900MHz Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 906.0  -  924.0 0.102  

Single Limited Modular Approval. Output power listed is conducted. This device is authorized for installation in Grantee's devices and may not be marketed to the general public. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits at the distance specified in the filing, therefore, this device may be used in mobile configurations. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. End -users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application YBLIhJ/ft4uEc5xv/z05Ng==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Schlage Lock Company
11819 N. Pennsylvania Street
Carmel, IN 46032
United States
  Date of Grant: 03/11/2022

Application Dated: 03/11/2022
 
Attention: Frank Nardelli , Lead Hardware Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XPB-COMAD400V3
Name of Grantee:  Schlage Lock Company
Equipment Class: Digital Transmission System
Notes: 900MHz Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 906.0  -  924.0 0.102  

Single Limited Modular Approval. Output power listed is conducted. This device is authorized for installation in Grantee's devices and may not be marketed to the general public. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits at the distance specified in the filing, therefore, this device may be used in mobile configurations. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. End -users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: