FCC ID XS5-CAPH17E19

Era repeater for cellular systems

by Andrew Wireless System

Grantee Code: XS5   Product Code: CAPH17E19
Latest application date: 2019-02-08

FCC ID Device Details

FCC IDXS5-CAPH17E19
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXS5
Product CodeCAPH17E19
Applicant BusinessAndrew Wireless System 🇩🇪
Related Domains commscope.com
Equipment ClassEra repeater for cellular systems
Test Firm7layers GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1930-1995 MHzOriginal Equipment2019-02-08

Exhibits

DocumentTypeAvailableFile
Installation InstructionUsers Manual2019-07-19PDF 444 KB
User Manual IUsers Manual2019-07-19PDF 3.3 MB
int photosInternal Photos2019-07-19PDF 2.8 MB
ext photosExternal Photos2019-02-08PDF 1.3 MB
LabelID Label/Location Info2019-02-08PDF 84.9 KB
test setup photosTest Setup Photos2019-02-08PDF 868.2 KB
Test ReportTest Report2019-02-08PDF 3.2 MB
test reportTest Report2019-02-08PDF 5.6 MB
Label Attestation LetterAttestation Statements2019-02-08PDF 513.5 KB
LTC requestCover Letter(s)2019-02-08PDF 329.2 KB
PoACover Letter(s)2019-02-08PDF 387.2 KB
RF ExposueRF Exposure Info2019-02-08PDF 503 KB
Block Diagram Metadata onlyBlock DiagramPDF 328.4 KB
Schematics I Metadata onlySchematicsPDF 1.9 MB
Schematics II Metadata onlySchematicsPDF 4.2 MB
Data sheet Metadata onlyOperational DescriptionPDF 408 KB
Operational Description Metadata onlyOperational DescriptionPDF 678 KB
Parts list Metadata onlyParts List/Tune Up InfoPDF 132.2 KB
Tune up Metadata onlyParts List/Tune Up InfoPDF 299.3 KB

Application Information

Application IDrAhki46E4d1nG+CB81UQCA==
Final Action Date2019-02-08
Application PurposeOriginal Equipment
Applicant FRN0019152750
ModelCAPH17E19
Frequency Range1930-1995 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device DescriptionEra repeater for cellular systems
Responsible PartyWolfgang Oelrich, Manager Quality, wolfgang.oelrich@commscope.com , +49-9099-69
AgentFank Fank Fank, Andrew Wireless Systems, frank.futter@commscope.com , +49909969
Test FirmBernhard Retka, 7layers GmbH, Bernhard.Retka@7layers.com , 0049 2102 749 452
TCB EmailKhalek.Yassine@phoenix-testlab.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date07/19/2019
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is the rated conducted composite combined power based on one carrier. This is a remote unit that supports 2TX MIMO configuration and is connected via a fiber optical link to the ERA Master unit as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
rAhki46E4d1nG+CB81UQCA==2019-02-08Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1930-1995 MHz40AmpGXW24E
1930-1995 MHz40AmpG7W24E
1930-1995 MHz40AmpF9W24E
1930-1995 MHz40AmpG7D24E
2110-2180 MHz40AmpG7D27
2110-2180 MHz40AmpF9W27

Grants

TCB Grant - Application rAhki46E4d1nG+CB81UQCA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 02/08/2019

Application Dated: 02/08/2019
Andrew Wireless System
Industriering 10
Buchdorf, 86675
Germany
 
Attention: Wolfgang Oelrich , Manager Quality

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XS5-CAPH17E19
Name of Grantee:  Andrew Wireless System
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Era repeater for cellular systems
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1930.0  -  1995.0 40.0  Amp GXW
24E 1930.0  -  1995.0 40.0  Amp G7W
24E 1930.0  -  1995.0 40.0  Amp F9W
24E 1930.0  -  1995.0 40.0  Amp G7D
27 2110.0  -  2180.0 40.0  Amp G7D
27 2110.0  -  2180.0 40.0  Amp F9W

Output power listed is the rated conducted composite combined power based on one carrier. This is a remote unit that supports 2TX MIMO configuration and is connected via a fiber optical link to the ERA Master unit as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

EAS Grant - Application rAhki46E4d1nG+CB81UQCA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Andrew Wireless System
Industriering 10
Buchdorf, 86675
Germany
  Date of Grant: 02/08/2019

Application Dated: 02/08/2019
 
Attention: Wolfgang Oelrich , Manager Quality

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XS5-CAPH17E19
Name of Grantee:  Andrew Wireless System
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: Era repeater for cellular systems
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1930.0  -  1995.0 40.0  Amp GXW
24E 1930.0  -  1995.0 40.0  Amp G7W
24E 1930.0  -  1995.0 40.0  Amp F9W
24E 1930.0  -  1995.0 40.0  Amp G7D
27 2110.0  -  2180.0 40.0  Amp G7D
27 2110.0  -  2180.0 40.0  Amp F9W

Output power listed is the rated conducted composite combined power based on one carrier. This is a remote unit that supports 2TX MIMO configuration and is connected via a fiber optical link to the ERA Master unit as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).



Mail To: