FCC ID XS5-CAPH17E19
Era repeater for cellular systems
by Andrew Wireless System
Grantee Code: XS5 Product Code: CAPH17E19
Latest application date: 2019-02-08
FCC ID Device Details
| FCC ID | XS5-CAPH17E19 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XS5 |
| Product Code | CAPH17E19 |
| Applicant Business | Andrew Wireless System 🇩🇪 |
| Related Domains | |
| Equipment Class | Era repeater for cellular systems |
| Test Firm | 7layers GmbH |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1930-1995 MHz | Original Equipment | 2019-02-08 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Installation Instruction | Users Manual | 2019-07-19 | PDF 444 KB |
| User Manual I | Users Manual | 2019-07-19 | PDF 3.3 MB |
| int photos | Internal Photos | 2019-07-19 | PDF 2.8 MB |
| ext photos | External Photos | 2019-02-08 | PDF 1.3 MB |
| Label | ID Label/Location Info | 2019-02-08 | PDF 84.9 KB |
| test setup photos | Test Setup Photos | 2019-02-08 | PDF 868.2 KB |
| Test Report | Test Report | 2019-02-08 | PDF 3.2 MB |
| test report | Test Report | 2019-02-08 | PDF 5.6 MB |
| Label Attestation Letter | Attestation Statements | 2019-02-08 | PDF 513.5 KB |
| LTC request | Cover Letter(s) | 2019-02-08 | PDF 329.2 KB |
| PoA | Cover Letter(s) | 2019-02-08 | PDF 387.2 KB |
| RF Exposue | RF Exposure Info | 2019-02-08 | PDF 503 KB |
| Block Diagram Metadata only | Block Diagram | PDF 328.4 KB | |
| Schematics I Metadata only | Schematics | PDF 1.9 MB | |
| Schematics II Metadata only | Schematics | PDF 4.2 MB | |
| Data sheet Metadata only | Operational Description | PDF 408 KB | |
| Operational Description Metadata only | Operational Description | PDF 678 KB | |
| Parts list Metadata only | Parts List/Tune Up Info | PDF 132.2 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 299.3 KB |
Application Information
| Application ID | rAhki46E4d1nG+CB81UQCA== |
|---|---|
| Final Action Date | 2019-02-08 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0019152750 |
| Model | CAPH17E19 |
| Frequency Range | 1930-1995 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | Era repeater for cellular systems |
| Responsible Party | Wolfgang Oelrich, Manager Quality, wolfgang.oelrich@commscope.com |
| Agent | Fank Fank Fank, Andrew Wireless Systems, frank.futter@commscope.com |
| Test Firm | Bernhard Retka, 7layers GmbH, Bernhard.Retka@7layers.com |
| TCB Email | Khalek.Yassine@phoenix-testlab.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 07/19/2019 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is the rated conducted composite combined power based on one carrier. This is a remote unit that supports 2TX MIMO configuration and is connected via a fiber optical link to the ERA Master unit as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| rAhki46E4d1nG+CB81UQCA== | 2019-02-08 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application rAhki46E4d1nG+CB81UQCA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 02/08/2019 Application Dated: 02/08/2019 |
| Andrew Wireless System |
| Industriering 10 |
| Buchdorf, 86675 Germany |
| Attention: Wolfgang Oelrich , Manager Quality |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XS5-CAPH17E19 |
| Name of Grantee: | Andrew Wireless System |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Era repeater for cellular systems |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1930.0 - 1995.0 | 40.0 | Amp | GXW | |
| 24E | 1930.0 - 1995.0 | 40.0 | Amp | G7W | |
| 24E | 1930.0 - 1995.0 | 40.0 | Amp | F9W | |
| 24E | 1930.0 - 1995.0 | 40.0 | Amp | G7D | |
| 27 | 2110.0 - 2180.0 | 40.0 | Amp | G7D | |
| 27 | 2110.0 - 2180.0 | 40.0 | Amp | F9W |
| Output power listed is the rated conducted composite combined power based on one carrier. This is a remote unit that supports 2TX MIMO configuration and is connected via a fiber optical link to the ERA Master unit as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
EAS Grant - Application rAhki46E4d1nG+CB81UQCA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Andrew Wireless System Industriering 10 Buchdorf, 86675 Germany |
Date of Grant: 02/08/2019 Application Dated: 02/08/2019 |
| Attention: Wolfgang Oelrich , Manager Quality |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XS5-CAPH17E19 |
| Name of Grantee: | Andrew Wireless System |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | Era repeater for cellular systems |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1930.0 - 1995.0 | 40.0 | Amp | GXW | |
| 24E | 1930.0 - 1995.0 | 40.0 | Amp | G7W | |
| 24E | 1930.0 - 1995.0 | 40.0 | Amp | F9W | |
| 24E | 1930.0 - 1995.0 | 40.0 | Amp | G7D | |
| 27 | 2110.0 - 2180.0 | 40.0 | Amp | G7D | |
| 27 | 2110.0 - 2180.0 | 40.0 | Amp | F9W |
| Output power listed is the rated conducted composite combined power based on one carrier. This is a remote unit that supports 2TX MIMO configuration and is connected via a fiber optical link to the ERA Master unit as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
| Mail To: |