FCC ID XS5-CAPL17E19
ION-E Remote Unit for cellular systems
by Andrew Wireless System
Grantee Code: XS5 Product Code: CAPL17E19
Latest application date: 2018-03-02
FCC ID Device Details
| FCC ID | XS5-CAPL17E19 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XS5 |
| Product Code | CAPL17E19 |
| Applicant Business | Andrew Wireless System 🇩🇪 |
| Related Domains | |
| Equipment Class | ION-E Remote Unit for cellular systems |
| Test Firm | 7layers GmbH |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1930-1995 MHz | Original Equipment | 2018-03-02 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2018-04-30 | PDF 4.2 MB |
| int photos | Internal Photos | 2018-04-30 | PDF 800.8 KB |
| ext photos | External Photos | 2018-03-02 | PDF 590.5 KB |
| Label | ID Label/Location Info | 2018-03-02 | PDF 1.6 MB |
| Label and Location | ID Label/Location Info | 2018-03-02 | PDF 236.7 KB |
| test setup photos | Test Setup Photos | 2018-03-02 | PDF 912.7 KB |
| Test report | Test Report | 2018-03-02 | PDF 3.8 MB |
| Test report 1700MHZ | Test Report | 2018-03-02 | PDF 2.5 MB |
| test report a | Test Report | 2018-03-02 | PDF 880.1 KB |
| test report b | Test Report | 2018-03-02 | PDF 965.8 KB |
| attestation letter label | Attestation Statements | 2018-03-02 | PDF 516.8 KB |
| FCC Referencing Test Data 17E | Cover Letter(s) | 2018-03-02 | PDF 365.2 KB |
| FCC Referencing Test Data 19 | Cover Letter(s) | 2018-03-02 | PDF 363 KB |
| LTC Request | Cover Letter(s) | 2018-03-02 | PDF 331.2 KB |
| PoA | Cover Letter(s) | 2018-03-02 | PDF 301.4 KB |
| RF exposure | RF Exposure Info | 2018-03-02 | PDF 104.5 KB |
| block diagram Metadata only | Block Diagram | PDF 69.2 KB | |
| schematics Metadata only | Schematics | PDF 2.9 MB | |
| operational description Metadata only | Operational Description | PDF 208.4 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 94.3 KB | |
| parts list Metadata only | Parts List/Tune Up Info | PDF 37.1 KB |
Application Information
| Application ID | No6w9144+sxuIDAoqZzwnQ== |
|---|---|
| Final Action Date | 2018-03-02 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0019152750 |
| Model | CAPL17E19 |
| Frequency Range | 1930-1995 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | ION-E Remote Unit for cellular systems |
| Responsible Party | Wolfgang Oelrich, Manager Quality, wolfgang.oelrich@commscope.com |
| Test Firm | Bernhard Retka, 7layers GmbH, Bernhard.Retka@7layers.com |
| TCB Email | khalek.yassine@phoenix-testlab.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 04/30/2018 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is the maximum conducted composite combined power based on one carrier. This device is a remote unit used with a Master Unit (CAN/TEN) in the ION distribution System and it supports 2TX MIMO configuration. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| No6w9144+sxuIDAoqZzwnQ== | 2018-03-02 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application No6w9144+sxuIDAoqZzwnQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 03/02/2018 Application Dated: 03/02/2018 |
| Andrew Wireless System |
| Industriering 10 |
| Buchdorf, 86675 Germany |
| Attention: Wolfgang Oelrich , Manager Quality |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XS5-CAPL17E19 |
| Name of Grantee: | Andrew Wireless System |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ION-E Remote Unit for cellular systems |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 27 | 2110.0 - 2180.0 | 0.26 | Amp | F9W |
| MO | 27 | 2110.0 - 2180.0 | 0.26 | Amp | G7D |
| MO | 24E | 1930.0 - 1995.0 | 0.26 | Amp | GXW |
| MO | 24E | 1930.0 - 1995.0 | 0.26 | Amp | G7W |
| MO | 24E | 1930.0 - 1995.0 | 0.26 | Amp | F9W |
| MO | 24E | 1930.0 - 1995.0 | 0.26 | Amp | G7D |
| Output power listed is the maximum conducted composite combined power based on one carrier. This device is a remote unit used with a Master Unit (CAN/TEN) in the ION distribution System and it supports 2TX MIMO configuration. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application No6w9144+sxuIDAoqZzwnQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Andrew Wireless System Industriering 10 Buchdorf, 86675 Germany |
Date of Grant: 03/02/2018 Application Dated: 03/02/2018 |
| Attention: Wolfgang Oelrich , Manager Quality |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XS5-CAPL17E19 |
| Name of Grantee: | Andrew Wireless System |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ION-E Remote Unit for cellular systems |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 27 | 2110.0 - 2180.0 | 0.26 | Amp | F9W |
| MO | 27 | 2110.0 - 2180.0 | 0.26 | Amp | G7D |
| MO | 24E | 1930.0 - 1995.0 | 0.26 | Amp | GXW |
| MO | 24E | 1930.0 - 1995.0 | 0.26 | Amp | G7W |
| MO | 24E | 1930.0 - 1995.0 | 0.26 | Amp | F9W |
| MO | 24E | 1930.0 - 1995.0 | 0.26 | Amp | G7D |
| Output power listed is the maximum conducted composite combined power based on one carrier. This device is a remote unit used with a Master Unit (CAN/TEN) in the ION distribution System and it supports 2TX MIMO configuration. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |