FCC ID XS5-CAPL17E192325
ION-E Remote Unit for cellular systems
by Andrew Wireless System
Grantee Code: XS5 Product Code: CAPL17E192325
Latest application date: 2018-03-28
FCC ID Device Details
| FCC ID | XS5-CAPL17E192325 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XS5 |
| Product Code | CAPL17E192325 |
| Applicant Business | Andrew Wireless System 🇩🇪 |
| Related Domains | |
| Equipment Class | ION-E Remote Unit for cellular systems |
| Test Firm | 7layers GmbH |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1930-1995 MHz | Original Equipment | 2018-03-28 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2018-09-06 | PDF 4.2 MB |
| int photos | Internal Photos | 2018-09-06 | PDF 771.9 KB |
| ext photos | External Photos | 2018-03-28 | PDF 435.1 KB |
| Label | ID Label/Location Info | 2018-03-28 | PDF 160.3 KB |
| Label and Location | ID Label/Location Info | 2018-03-28 | PDF 235.3 KB |
| Test Setup photos | Test Setup Photos | 2018-03-28 | PDF 1.1 MB |
| test setup photos | Test Setup Photos | 2018-03-28 | PDF 1 MB |
| Referencing test data 17E | Test Report | 2018-03-28 | PDF 366.1 KB |
| Referencing test data 19 | Test Report | 2018-03-28 | PDF 364.8 KB |
| Referencing test data 23 | Test Report | 2018-03-28 | PDF 366.4 KB |
| Test report 1700MHz | Test Report | 2018-03-28 | PDF 2.5 MB |
| Test report 2300MHz | Test Report | 2018-03-28 | PDF 3.2 MB |
| Test report I | Test Report | 2018-03-28 | PDF 5.5 MB |
| Test report II | Test Report | 2018-03-28 | PDF 5.2 MB |
| test report b | Test Report | 2018-03-28 | PDF 3.8 MB |
| Labeling Attestatiojn letter | Attestation Statements | 2018-03-28 | PDF 516.8 KB |
| LTC Request | Cover Letter(s) | 2018-03-28 | PDF 337.6 KB |
| PoA | Cover Letter(s) | 2018-03-28 | PDF 301.4 KB |
| RF expsoure | RF Exposure Info | 2018-03-28 | PDF 226.8 KB |
| block diagram Metadata only | Block Diagram | PDF 933.4 KB | |
| schematics Metadata only | Schematics | PDF 3.2 MB | |
| operational description Metadata only | Operational Description | PDF 274.1 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 95.1 KB | |
| parts list Metadata only | Parts List/Tune Up Info | PDF 38.2 KB |
Application Information
| Application ID | RG+SOZ3culM9/3W490yuYw== |
|---|---|
| Final Action Date | 2018-03-28 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0019152750 |
| Model | CAPL17E192325 |
| Frequency Range | 1930-1995 MHz |
| Equipment Class | B2I - Part 20 Industrial Booster (CMRS) |
| Device Description | ION-E Remote Unit for cellular systems |
| Responsible Party | Wolfgang Oelrich, Manager Quality, wolfgang.oelrich@commscope.com |
| Test Firm | Bernhard Retka, 7layers GmbH, Bernhard.Retka@7layers.com |
| TCB Email | khalek.yassine@phoenix-testlab.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 09/06/2018 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is the maximum conducted composite power based on one carrier. This device is used with ION-CAN / TEN systems. The antenna(s) used for this transmitter (repeater) must be fixedmounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna colocation requirements of §1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| RG+SOZ3culM9/3W490yuYw== | 2018-03-28 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application RG+SOZ3culM9/3W490yuYw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 03/28/2018 Application Dated: 03/28/2018 |
| Andrew Wireless System |
| Industriering 10 |
| Buchdorf, 86675 Germany |
| Attention: Wolfgang Oelrich , Manager Quality |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XS5-CAPL17E192325 |
| Name of Grantee: | Andrew Wireless System |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ION-E Remote Unit for cellular systems |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1930.0 - 1995.0 | 0.13 | Amp | GXW | |
| 24E | 1930.0 - 1995.0 | 0.13 | Amp | G7W | |
| 24E | 1930.0 - 1995.0 | 0.13 | Amp | F9W | |
| 24E | 1930.0 - 1995.0 | 0.13 | Amp | G7D | |
| 27 | 2110.0 - 2180.0 | 0.13 | Amp | F9W | |
| 27 | 2110.0 - 2180.0 | 0.13 | Amp | G7D | |
| 27 | 2350.0 - 2360.0 | 0.13 | Amp | G7D | |
| 27 | 2496.0 - 2690.0 | 0.13 | Amp | G7D |
| Output power listed is the maximum conducted composite power based on one carrier. This device is used with ION-CAN / TEN systems. The antenna(s) used for this transmitter (repeater) must be fixedmounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna colocation requirements of §1.1307(b)(3). |
EAS Grant - Application RG+SOZ3culM9/3W490yuYw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Andrew Wireless System Industriering 10 Buchdorf, 86675 Germany |
Date of Grant: 03/28/2018 Application Dated: 03/28/2018 |
| Attention: Wolfgang Oelrich , Manager Quality |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XS5-CAPL17E192325 |
| Name of Grantee: | Andrew Wireless System |
| Equipment Class: | Part 20 Industrial Booster (CMRS) |
| Notes: | ION-E Remote Unit for cellular systems |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1930.0 - 1995.0 | 0.13 | Amp | GXW | |
| 24E | 1930.0 - 1995.0 | 0.13 | Amp | G7W | |
| 24E | 1930.0 - 1995.0 | 0.13 | Amp | F9W | |
| 24E | 1930.0 - 1995.0 | 0.13 | Amp | G7D | |
| 27 | 2110.0 - 2180.0 | 0.13 | Amp | F9W | |
| 27 | 2110.0 - 2180.0 | 0.13 | Amp | G7D | |
| 27 | 2350.0 - 2360.0 | 0.13 | Amp | G7D | |
| 27 | 2496.0 - 2690.0 | 0.13 | Amp | G7D |
| Output power listed is the maximum conducted composite power based on one carrier. This device is used with ION-CAN / TEN systems. The antenna(s) used for this transmitter (repeater) must be fixedmounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna colocation requirements of §1.1307(b)(3). |
| Mail To: |