FCC ID XS5-IONM1719HP
ION-M17HP/19HP
by Andrew Wireless System
Grantee Code: XS5 Product Code: IONM1719HP
Latest application date: 2011-11-16
FCC ID Device Details
| FCC ID | XS5-IONM1719HP |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XS5 |
| Product Code | IONM1719HP |
| Applicant Business | Andrew Wireless System 🇩🇪 |
| Related Domains | |
| Equipment Class | ION-M17HP/19HP |
| Test Firm | Bureau Veritas Consumer Products Services Germany |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1930-1995 MHz | Original Equipment | 2011-11-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2012-03-31 | PDF 1 MB |
| internal photos | Internal Photos | 2012-03-31 | PDF 2.1 MB |
| external photos | External Photos | 2011-11-16 | PDF 217.9 KB |
| label | ID Label/Location Info | 2011-11-16 | PDF 182.6 KB |
| test setup photos | Test Setup Photos | 2011-11-16 | PDF 203.7 KB |
| installation instruction | Test Report | 2011-11-16 | PDF 83.9 KB |
| test report | Test Report | 2011-11-16 | PDF 871.1 KB |
| request for confidentiality | Cover Letter(s) | 2011-11-16 | PDF 556.2 KB |
| MPE | RF Exposure Info | 2011-11-16 | PDF 66.6 KB |
Application Information
| Application ID | xo3h706xKD16bqNwp9wQWg== |
|---|---|
| Final Action Date | 2011-11-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0019152750 |
| Model | -IONM1719HP |
| Frequency Range | 1930-1995 MHz |
| Equipment Class | AMP - Amplifier |
| Device Description | ION-M17HP/19HP |
| Responsible Party | Siegfried Schwenk, Reliability Manager, siegfried.schwenk@andrew.com |
| Test Firm | Mario Lehmann, Bureau Veritas Consumer Products Services Germany, mario.lehmann@de.bureauveritas.com |
| TCB Email | dollitz.uwe@phoenix-testlab.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 03/31/2012 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a maximum gain of 17.15 dBi. Operating is limited to a maximum antenna hight of 10m above ground per 27.50(d)(2). RF exposure compliance must be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). This device must be professionally installed. EUT connected to Master Unit. NOTE 1: F9W, G7D NOTE 2: GXW, G7W, F9W, G7D |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| xo3h706xKD16bqNwp9wQWg== | 2011-11-16 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application xo3h706xKD16bqNwp9wQWg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 11/16/2011 Application Dated: 11/16/2011 |
| Andrew Wireless System |
| Industriering 10 |
| Buchdorf, 86675 Germany |
| Attention: Siegfried Schwenk , Reliability Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XS5-IONM1719HP |
| Name of Grantee: | Andrew Wireless System |
| Equipment Class: | Amplifier |
| Notes: | ION-M17HP/19HP |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 2110.0 - 2155.0 | 31.6 | Amp | NOTE 1 | |
| 24 | 1930.0 - 1995.0 | 31.6 | Amp | NOTE 2 |
| Antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a maximum gain of 17.15 dBi. Operating is limited to a maximum antenna hight of 10m above ground per 27.50(d)(2). RF exposure compliance must be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). This device must be professionally installed. EUT connected to Master Unit. NOTE 1: F9W, G7D NOTE 2: GXW, G7W, F9W, G7D |
EAS Grant - Application xo3h706xKD16bqNwp9wQWg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Andrew Wireless System Industriering 10 Buchdorf, 86675 Germany |
Date of Grant: 11/16/2011 Application Dated: 11/16/2011 |
| Attention: Siegfried Schwenk , Reliability Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XS5-IONM1719HP |
| Name of Grantee: | Andrew Wireless System |
| Equipment Class: | Amplifier |
| Notes: | ION-M17HP/19HP |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 27 | 2110.0 - 2155.0 | 31.6 | Amp | NOTE 1 | |
| 24 | 1930.0 - 1995.0 | 31.6 | Amp | NOTE 2 |
| Antenna(s) used for this transmitter must be fixed-mounted on indoor or outdoor permanent structures with a maximum gain of 17.15 dBi. Operating is limited to a maximum antenna hight of 10m above ground per 27.50(d)(2). RF exposure compliance must be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3). This device must be professionally installed. EUT connected to Master Unit. NOTE 1: F9W, G7D NOTE 2: GXW, G7W, F9W, G7D |
| Mail To: |