FCC ID XS5-UEUH2323

ION-U Extension Unit for cellular systems

by Andrew Wireless System

Grantee Code: XS5   Product Code: UEUH2323
Latest application date: 2015-09-16

Device Images

FCC ID Device Details

FCC IDXS5-UEUH2323
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXS5
Product CodeUEUH2323
Applicant BusinessAndrew Wireless System 🇩🇪
Related Domains commscope.com
Equipment ClassION-U Extension Unit for cellular systems
Test FirmBureau Veritas Consumer Products Services Germany

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2350-2360 MHzOriginal Equipment2015-09-16

Exhibits

DocumentTypeAvailableFile
Installation InstructionUsers Manual2016-03-04PDF 99.1 KB
user manualUsers Manual2016-03-04PDF 2.4 MB
int photosInternal Photos2016-03-04PDF 3.6 MB
ext photosExternal Photos2015-09-16PDF 771.5 KB
label locationID Label/Location Info2015-09-16PDF 128.6 KB
test setup photosTest Setup Photos2015-09-16PDF 1.8 MB
Test reportTest Report2015-09-16PDF 4.1 MB
Attestation letterAttestation Statements2015-09-16PDF 219.2 KB
LTC requestCover Letter(s)2015-09-16PDF 335.4 KB
PoACover Letter(s)2015-09-16PDF 301.4 KB
RF ExposureRF Exposure Info2015-09-16PDF 336.4 KB
block diagram Metadata onlyBlock DiagramPDF 286.1 KB
schematics Metadata onlySchematicsPDF 3.8 MB
operational description Metadata onlyOperational DescriptionPDF 258.9 KB
parts list Metadata onlyParts List/Tune Up InfoPDF 66.5 KB
tune up Metadata onlyParts List/Tune Up InfoPDF 96.7 KB

Application Information

Application ID0COfYGg5CwW60hBmgLuoMA==
Final Action Date2015-09-16
Application PurposeOriginal Equipment
Applicant FRN0019152750
ModelUEUH2323
Frequency Range2350-2360 MHz
Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
Device DescriptionION-U Extension Unit for cellular systems
Responsible PartyWolfgang Oelrich, Manager Quality, wolfgang.oelrich@commscope.com , +49-9099-69
Test FirmMario Lehmann, Bureau Veritas Consumer Products Services Germany, mario.lehmann@de.bureauveritas.com , 49-40-74041-2702
TCB EmailKhalek.Yassine@phoenix-testlab.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/04/2016
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is the maximum conducted composite combined power based on one carrier. This is an extension unit that supports 2TX MIMO configuration. It must be either operated in a system with the remote unit (FCC ID: XS5-UH781719P) or in a system consisting of the remote unit (FCC ID: XS5-UH781719P) together with the extension unit (FCC ID: XS5-UEUH781719P) as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

Applications

Application IDDatePurpose
0COfYGg5CwW60hBmgLuoMA==2015-09-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
2350-2360 MHz31.8000000AmpG7D27MO

Grants

TCB Grant - Application 0COfYGg5CwW60hBmgLuoMA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 09/16/2015

Application Dated: 09/16/2015
Andrew Wireless System
Industriering 10
Buchdorf, 86675
Germany
 
Attention: Wolfgang Oelrich , Manager Quality

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XS5-UEUH2323
Name of Grantee:  Andrew Wireless System
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: ION-U Extension Unit for cellular systems
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 27 2350.0  -  2360.0 31.8  Amp G7D

Output power listed is the maximum conducted composite combined power based on one carrier. This is an extension unit that supports 2TX MIMO configuration. It must be either operated in a system with the remote unit (FCC ID: XS5-UH781719P) or in a system consisting of the remote unit (FCC ID: XS5-UH781719P) together with the extension unit (FCC ID: XS5-UEUH781719P) as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 0COfYGg5CwW60hBmgLuoMA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Andrew Wireless System
Industriering 10
Buchdorf, 86675
Germany
  Date of Grant: 09/16/2015

Application Dated: 09/16/2015
 
Attention: Wolfgang Oelrich , Manager Quality

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XS5-UEUH2323
Name of Grantee:  Andrew Wireless System
Equipment Class: Part 20 Industrial Booster (CMRS)
Notes: ION-U Extension Unit for cellular systems
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 27 2350.0  -  2360.0 31.8  Amp G7D

Output power listed is the maximum conducted composite combined power based on one carrier. This is an extension unit that supports 2TX MIMO configuration. It must be either operated in a system with the remote unit (FCC ID: XS5-UH781719P) or in a system consisting of the remote unit (FCC ID: XS5-UH781719P) together with the extension unit (FCC ID: XS5-UEUH781719P) as described in this filing. The antenna(s) used for this transmitter (repeater) must be fixed-mounted on permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of §1.1307(b)(3).


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: