FCC ID XUJCRP123V3ARM

Professional Diagnostic Tool

by Launch Tech Co., Ltd.

Grantee Code: XUJ   Product Code: CRP123V3ARM
Latest application date: 2025-09-12

FCC ID Device Details

FCC IDXUJCRP123V3ARM
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXUJ
Product CodeCRP123V3ARM
Applicant BusinessLaunch Tech Co., Ltd. 🇨🇳
Related Domains cnlaunch.com
Equipment ClassProfessional Diagnostic Tool
Test FirmSHENZHEN STS TEST SERVICES CO.,LTD.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5745-5825 MHzOriginal Equipment2025-09-12
2412-2462 MHzOriginal Equipment2025-09-12

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2026-03-11PDF 924.4 KB
Internal PhotosInternal Photos2026-03-11PDF 1.3 MB
External PhotosExternal Photos2026-03-11PDF 1.6 MB
FCC LabelID Label/Location Info2025-09-12PDF 166.2 KB
RF setup photoTest Setup Photos2026-03-11PDF 545 KB
SAR Test setup photoTest Setup Photos2026-03-11PDF 244.8 KB
5G WIFITest Report2025-09-12PDF 1.7 MB
Antenna SpecificationTest Report2025-09-12PDF 856.3 KB
Appendix 5G WIFI U-NII-1Test Report2025-09-12PDF 2.2 MB
Appendix 5G WIFI U-NII-3Test Report2025-09-12PDF 2.3 MB
RF Part 15.247Test Report2025-09-12PDF 4 MB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2025-09-12PDF 325 KB
2.911 (d)(5)(ii)CertificationApplicantv1.3Attestation Statements2025-09-12PDF 311.1 KB
2.911 (d)(7)USAgentforServiceofProcessv1.3Attestation Statements2025-09-12PDF 131.8 KB
Agent Authorization Rev 1.0Cover Letter(s)2025-09-12PDF 53.8 KB
Antenna SpecificationCover Letter(s)2025-09-12PDF 856.3 KB
Authorization LetterCover Letter(s)2025-09-12PDF 56.2 KB
Authorization Letter for STS LabCover Letter(s)2025-09-12PDF 122.1 KB
FCC Differences DescriptionCover Letter(s)2025-09-12PDF 119.6 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2025-09-12PDF 157.3 KB
FCC Software Configuration Control Declaration Rev1.1Cover Letter(s)2025-09-12PDF 155.2 KB
SARRF Exposure Info2025-09-12PDF 1.9 MB
SAR Calibration ReportRF Exposure Info2025-09-12PDF 4.6 MB
SAR Dipole Performance Measurement ReportRF Exposure Info2025-09-12PDF 190.7 KB
SAR Tune Up ProcedureParts List/Tune Up Info2025-09-12PDF 83.6 KB
SAR Tune Up ProcedureRF Exposure Info2025-09-12PDF 83.6 KB
Block Diaggram Metadata onlyBlock DiagramPDF 266.8 KB
SCH Metadata onlySchematicsPDF 563.1 KB
OP Metadata onlyOperational DescriptionPDF 38.5 KB
FCC Software Security Requirement For U-NII Devices Metadata onlySDR Software/Security Info.PDF 326 KB

Application Information

Application IDszxdr8ZEslfBV2iARfzH2Q==
Final Action Date2025-09-12
Application PurposeOriginal Equipment
Applicant FRN0019193101
ModelCRP123V3ARM
Frequency Range5745-5825 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionProfessional Diagnostic Tool
Responsible PartyIvy Zhong, lihua.zhong@cnlaunch.com , (86)755-84528007
Technical ContactLaunch Tech Co., Ltd., lihua.zhong@cnlaunch.com
Test FirmBovey Yang, SHENZHEN STS TEST SERVICES CO.,LTD., Bovey@stsapp.com , 86-755-36886288
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
szxdr8ZEslfBV2iARfzH2Q==2025-09-12Original Equipment
2KnqHR796iis8UMkoHZVxQ==2025-09-12Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
5180-5240 MHz0.012515ECC
5745-5825 MHz0.011215ECC
2412-2462 MHz0.029215CCC

Grants

TCB Grant - Application szxdr8ZEslfBV2iARfzH2Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 09/12/2025

Application Dated: 09/12/2025
Launch Tech Co., Ltd.
No.4012, Launch Industrial Park, North Wuhe Rd,
Bantian Street, Longgang District,
Shenzhen, 518129
China
 
Attention: Ivy Zhong , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XUJCRP123V3ARM
Name of Grantee:  Launch Tech Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Professional Diagnostic Tool
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0125  
CC 15E 5745.0  -  5825.0 0.0112  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.12 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 2KnqHR796iis8UMkoHZVxQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 09/12/2025

Application Dated: 09/12/2025
Launch Tech Co., Ltd.
No.4012, Launch Industrial Park, North Wuhe Rd,
Bantian Street, Longgang District,
Shenzhen, 518129
China
 
Attention: Ivy Zhong , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XUJCRP123V3ARM
Name of Grantee:  Launch Tech Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Professional Diagnostic Tool
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0292  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn is 0.20 W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.