FCC ID XUJWO0805A

AUTO Smart Diagnostic Tool

by Launch Tech Co., Ltd.

Grantee Code: XUJ   Product Code: WO0805A
Latest application date: 2023-04-25

FCC ID Device Details

FCC IDXUJWO0805A
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXUJ
Product CodeWO0805A
Applicant BusinessLaunch Tech Co., Ltd. 🇨🇳
Related Domains cnlaunch.com
Equipment ClassAUTO Smart Diagnostic Tool
Test FirmShenzhen Anbotek Compliance Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2023-04-25
2412-2462 MHzOriginal Equipment2023-04-25

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2023-04-25PDF 3.3 MB
User manualUsers Manual2023-04-25PDF 3.3 MB
Int photosInternal Photos2023-04-25PDF 3.6 MB
Internal PhotographsInternal Photos2023-04-25PDF 3.6 MB
External Photographs of EUTExternal Photos2023-04-25PDF 1.3 MB
External photoExternal Photos2023-04-25PDF 1.3 MB
LabelID Label/Location Info2023-04-25PDF 478.3 KB
Test Setup PhotosTest Setup Photos2023-04-25PDF 2.1 MB
ANTENNA reportTest Report2023-04-25PDF 786.1 KB
Antenna SpecificationTest Report2023-04-25PDF 786.1 KB
SAR Test ReportRF Exposure Info2023-04-25PDF 4.4 MB
Test ReportTest Report2023-04-25PDF 1.3 MB
test reportTest Report2023-04-25PDF 4.5 MB
test reportTest Report2023-04-25PDF 3.8 MB
Certification Equipment TypeAttestation Statements2023-04-25PDF 112.3 KB
Certificiation ApplicantAttestation Statements2023-04-25PDF 88.8 KB
US AgentAttestation Statements2023-04-25PDF 93.4 KB
US Agent for Service of ProcessAttestation Statements2023-04-25PDF 93.4 KB
Declaration Letter of Model DifferenceCover Letter(s)2023-04-25PDF 59.7 KB
FCC Long Term Only Confidentiality Request Rev4.1Cover Letter(s)2023-04-25PDF 63.3 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2023-04-25PDF 63.3 KB
FCC Software Configuration Control Declaration Rev1.1Cover Letter(s)2023-04-25PDF 92 KB
Letter of AuthorizationCover Letter(s)2023-04-25PDF 62.7 KB
SAR ReportRF Exposure Info2023-04-25PDF 4.4 MB
SAR reportRF Exposure Info2023-04-25PDF 4.3 MB
Block Diagram Metadata onlyBlock DiagramPDF 15.2 KB
block diagram Metadata onlyBlock DiagramPDF 15.2 KB
SCH Metadata onlySchematicsPDF 1.4 MB
Schematics Metadata onlySchematicsPDF 1.4 MB
Operation Description Metadata onlyOperational DescriptionPDF 125.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 125.5 KB
FCC Software Security Requirements for UNII devices Metadata onlySDR Software/Security InfPDF 139.3 KB

Application Information

Application IDjuC9sCXa+NxZAOeDlIvQSw==
Final Action Date2023-04-25
Application PurposeOriginal Equipment
Applicant FRN0019193101
ModelWO0805A
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionAUTO Smart Diagnostic Tool
Responsible PartyIvy Zhong, Manager, lihua.zhong@cnlaunch.com , (86)755-84528007
Technical ContactLaunch Tech Co., Ltd., lihua.zhong@cnlaunch.com
Test FirmJeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com , 13798230942
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.37W/kg.

Applications

Application IDDatePurpose
juC9sCXa+NxZAOeDlIvQSw==2023-04-25Original Equipment
QxNv8c9lPUxqvuuJBtRaxA==2023-04-25Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.032100015CCC
5180-5240 MHz0.015315ECC
5745-5825 MHz0.018615ECC

Grants

TCB Grant - Application QxNv8c9lPUxqvuuJBtRaxA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 04/25/2023

Application Dated: 04/25/2023
Launch Tech Co., Ltd.
Launch Industrial Park, North of Wuhe Rd.
Banxuegang, Longgang
Shenzhen, 518129
China
 
Attention: Ivy Zhong , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XUJWO0805A
Name of Grantee:  Launch Tech Co., Ltd.
Equipment Class: Digital Transmission System
Notes: AUTO Smart Diagnostic Tool
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0321  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.42W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application QxNv8c9lPUxqvuuJBtRaxA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Launch Tech Co., Ltd.
Launch Industrial Park, North of Wuhe Rd. Banxuegang, Longgang
Shenzhen, 518129
China
  Date of Grant: 04/25/2023

Application Dated: 04/25/2023
 
Attention: Ivy Zhong , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XUJWO0805A
Name of Grantee:  Launch Tech Co., Ltd.
Equipment Class: Digital Transmission System
Notes: AUTO Smart Diagnostic Tool
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0321  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.42W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application juC9sCXa+NxZAOeDlIvQSw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 04/25/2023

Application Dated: 04/25/2023
Launch Tech Co., Ltd.
Launch Industrial Park, North of Wuhe Rd.
Banxuegang, Longgang
Shenzhen, 518129
China
 
Attention: Ivy Zhong , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XUJWO0805A
Name of Grantee:  Launch Tech Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AUTO Smart Diagnostic Tool
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0153  
CC 15E 5745.0  -  5825.0 0.0186  

Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.37W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application juC9sCXa+NxZAOeDlIvQSw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Launch Tech Co., Ltd.
Launch Industrial Park, North of Wuhe Rd. Banxuegang, Longgang
Shenzhen, 518129
China
  Date of Grant: 04/25/2023

Application Dated: 04/25/2023
 
Attention: Ivy Zhong , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XUJWO0805A
Name of Grantee:  Launch Tech Co., Ltd.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: AUTO Smart Diagnostic Tool
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0153  
CC 15E 5745.0  -  5825.0 0.0186  

Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.37W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: