0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.

Y Soft Corporation, a.s. Ultralight P&C; Multireader MF+

Page 1 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 2 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 3 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 4 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 5 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 6 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 7 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 8 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 9 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 10 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 11 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 12 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 13 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 14 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 15 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 16 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 17 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Page 18 of 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.

REPORT No.:SZ17110212E01
TEST REPORT
APPLICANT
: Y Soft Corporation, a.s.
PRODUCT NAME
: Ultralight P&C Multireader MF+
MODEL NAME
: ML01065
BRAND NAME
: Y Soft SafeQ
FCC ID
: XUY0YX0ML01065
STANDARD(S)
: 47 CFR Part 15 Subpart B
TEST DATE
: 2018-03-01 to 2018-03-02
ISSUE DATE
: 2018-03-05
Tested by:
Peng Shiqing (Test Engineer)
Approved by:
Andy Yeh(Technical Director)
NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
REPORT No.:SZ17110212E01
DIRECTORY
1. Technical Information········································································································ 3
1.1. Applicant and Manufacturer Information····································································· 3
1.2. Equipment Under Test (EUT) Description ··································································· 3
2. Test Results ························································································································ 4
2.1. Applied Reference Documents ····················································································· 4
2.2. EUT Setup and Operating Conditions ·········································································· 5
3. 47 CFR Part 15B Requirements ······················································································· 6
3.1. Conducted Emission ······································································································ 6
3.2. Radiated Disturbance ··································································································· 10
Annex A Photographs of Test Setup ················································································· 14
Annex B Test Uncertainty ··································································································· 16
Annex C Testing Laboratory Information ········································································· 17
Change History
Issue
Date
Reason for change
1.0
2018-03-05
First edition
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 2 0f 18
REPORT No.:SZ17110212E01
1. Technical Information
Note: Provide by applicant
1.1. Applicant and Manufacturer Information
Applicant:
Y Soft Corporation, a.s.
Applicant Address:
U Kněžské louky 2151/18, Praha 3, 130 00, Czech Republic
Manufacturer:
Y Soft Corporation, a.s.
Manufacturer Address:
U Kněžské louky 2151/18, Praha 3, 130 00, Czech Republic
1.2. Equipment Under Test (EUT) Description
EUT Type:
Ultralight P&C Multireader MF+
Serial No:
(N/A, marked #1 by test site)
Hardware Version:
N/A
Software Version:
N/A
Tx Frequency:
125k/13.56MHz
Ancillary
Equipment:
AC Adapter
Brand Name:
SUNNY
Model No.:
SYS1541-2412
Serial No.:
(N/A, marked #1 by test site)
Rated Input:
Rated Output:
100-240V, 50/60Hz, 1.0A
12V,2.0A
Note: For a more detailed description, please refer to specification or user’s manual supplied by
the applicant and/or manufacturer.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 3 0f 18
REPORT No.:SZ17110212E01
2. Test Results
2.1. Applied Reference Documents
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:
No.
Identity
Document Title
47 CFR Part 15
Radio Frequency Devices
Test detailed items/section required by FCC rules and results are as below:
No.
Section
Description
Test Date
Test Engineer
Result
15.107
Conducted Emission
2018.03.01
Peng Shiqing
PASS
15.109
Radiated Emission
2018.03.01
Peng Shiqing
PASS
NOTE: The tests were performed according to the method of measurements prescribed in ANSI
C63.4-2014.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 4 0f 18
REPORT No.:SZ17110212E01
2.2. EUT Setup and Operating Conditions
Test Item
Radiated Emission
Mode 1
: EUT + Adapter + Printer
Mode 2
: EUT + Adapter + Telephone Line
Mode 3
: EUT + Adapter + Internet Access
Conducted Emission
Mode 1
: EUT + Adapter + Printer
Mode 2
: EUT + Adapter + Telephone Line
Mode 3
: EUT + Adapter + Internet Access
Remark:
The above test modes in boldface were the worst cases of conducted emission and radiated
emission tests; only the test data of these modes was reported.
During the measurement, the environmental conditions were within the listed ranges:
Temperature (°C):
15 - 35
Relative Humidity (%):
30 - 60
Atmospheric Pressure (kPa):
86 - 106
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 5 0f 18
REPORT No.:SZ17110212E01
3.
47 CFR Part 15B Requirements
3.1. Conducted Emission
3.1.1.
Requirement
According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).
Conducted Limit (dBµV)
Frequency range
(MHz)
Quasi-peak
Average
0.15 - 0.50
66 to 56
56 to 46
0.50 - 5
56
46
5 - 30
60
50
NOTE:
a) The limit subjects to the Class B digital device.
b) The lower limit shall apply at the band edges.
c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 0.50MHz.
3.1.2.
Test Setup
Please refer to Annex A for the photographs of the Test Configuration.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 6 0f 18
REPORT No.:SZ17110212E01
The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power
mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
test system are calibrated to correct the reading.
The power strip or extension cord has been investigated to make sure that the LISN integrity in
maintained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014
at
Clause 4.3.
3.1.3.
Test Result
The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average
(AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins
from the AV and QP limits will be re-measured with AV and QP detectors.Tests for both L phase
and N phase lines of the power mains connected to the EUT are performed. All test modes are
considered, refer to recorded points and plots below.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 7 0f 18
REPORT No.:SZ17110212E01
A. Test Plot and Suspicious Points:
(Plot A:L Phase)
Emission Level (dBµV)
Limit (dBµV)
NO.
Fre.
(MHz)
0.1800
47.15
36.73
64.49
54.49
PASS
0.4500
34.50
28.41
56.87
46.87
PASS
1.1300
29.20
23.26
56.00
46.00
2.9500
34.47
28.64
56.00
46.00
6.3949
30.51
24.45
60.00
50.00
PASS
16.254
25.25
19.08
60.00
50.00
PASS
MORLAB
Quai-peak
Average
Quai-peak
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Average
Power-line
Verdict
Line
PASS
PASS
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 8 0f 18
REPORT No.:SZ17110212E01
(Plot B: N Phase)
Emission Level (dBµV)
Limit (dBµV)
NO.
Fre.
(MHz)
0.1803
46.48
36.57
64.47
54.47
PASS
0.3397
36.72
30.61
59.21
49.21
PASS
0.8501
30.57
24.54
56.00
46.00
2.3103
36.45
30.54
56.00
46.00
6.3504
29.30
23.09
60.00
50.00
PASS
25.004
26.88
20.91
60.00
50.00
PASS
MORLAB
Quai-peak
Average
Quai-peak
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Average
Power-line
Verdict
Neutral
PASS
PASS
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 9 0f 18
REPORT No.:SZ17110212E01
3.2. Radiated Disturbance
3.2.1. Requirement
According to FCC section 15.109 (a), the field strength of radiated emissions from unintentional
radiators at a distance of 3 meters shall not exceed the following values:
Frequency
range (MHz)
Field Strength Limitation at 3m Measurement Dist
(µV/m)
(dBµV/m)
30.0 - 88.0
100
20log 100
88.0 - 216.0
150
20log 150
216.0 - 960.0
200
20log 200
Above 960.0
500
20log 500
As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength limits are
based on average detector. When average radiated emission measurements are specified in this
part, including emission measurements below 1000MHz, there also is a limit on the radio
frequency emissions, as measured using instrumentation with a peak detector function,
corresponding to 20dB above the maximum permitted average limit for the frequency being
investigated unless a different peak emission limit is otherwise specified in the rules.
Note:
1)
2)
The tighter limit shall apply at the boundary between two frequency range.
Limitation expressed in dBµV/m is calculated by 20log Emission Level(µV/m).
3.2.2. Frequency range of measurement
According to 15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the
following table:
The highest frequency of the internal sources of the EUT is less than 108MHz, the measurement
shall only be made up to 1G.
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 10 0f 18
REPORT No.:SZ17110212E01
3.2.3. Test Setup
1)
For radiated emissions from 30MHz to1GHz
The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating
Turn Table, and keeps 3m away from the Test Antenna, which is mounted onavariable-height
antenna master tower.
For the test Antenna:
In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) is used. Test
Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground
to determine the maximum value of the field strength. The emission levels at both horizontal and
vertical polarizations should be tested.
3.2.4.
Test Result
The maximum radiated emission is searched using PK, QP detectors; the emission levels more
than the limits, and that have narrow margins from the limits will be re-measured with QP detectors.
Both the vertical and the horizontal polarizations of the Test Antenna are considered to perform the
tests. All test modes are considered, refer to recorded points and plots below.
The amplitude of emissions which are attenuated more than 20 dB below the permissible value
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 11 0f 18
REPORT No.:SZ17110212E01
need not be reported.
Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis
test condition was recorded in this test report.
(Plot A: ANT-Vertical,30MHz - 1GHz)
Fre.
Pk
QP
AV
Limit-PK
Limit-QP
Limit-AV
MHz
dBµV/m
dBµV/m
dBµV/m
dBµV/m
dBµV/m
dBµV/m
34.850
27.55
N.A.
N.A.
N.A.
40.00
99.840
27.07
N.A.
N.A.
N.A.
275.410
35.19
N.A.
N.A.
350.100
38.27
N.A.
549.920
35.57
900.090
32.89
No.
MORLAB
ANT
Verdict
N.A.
PASS
43.50
N.A.
PASS
N.A.
46.00
N.A.
PASS
N.A.
N.A.
46.00
N.A.
PASS
N.A.
N.A.
N.A.
46.00
N.A.
PASS
N.A.
N.A.
N.A.
46.00
N.A.
PASS
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 12 0f 18
REPORT No.:SZ17110212E01
(Plot B:ANT- Horizontal, 30MHz - 1GHz)
Fre.
Pk
QP
AV
Limit-PK
Limit-QP
Limit-AV
MHz
dBµV/m
dBµV/m
dBµV/m
dBµV/m
dBµV/m
dBµV/m
31.940
31.27
N.A.
N.A.
N.A.
40.00
99.840
22.99
N.A.
N.A.
N.A.
299.660
31.59
N.A.
N.A.
399.570
33.27
N.A.
500.450
34.87
649.830
34.16
No.
MORLAB
ANT
Verdict
N.A.
PASS
43.50
N.A.
PASS
N.A.
46.00
N.A.
PASS
N.A.
N.A.
46.00
N.A.
PASS
N.A.
N.A.
N.A.
46.00
N.A.
PASS
N.A.
N.A.
N.A.
46.00
N.A.
PASS
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 13 0f 18
REPORT No.:SZ17110212E01
Annex A Photographs of Test Setup
1.
Mains Terminal Disturbance Voltage Measurement
2.
Conducted emission main’s port side view
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 14 0f 18
REPORT No.:SZ17110212E01
3.
Radiated Field Strength Measurement(30MHz-1GHz)
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 15 0f 18
REPORT No.:SZ17110212E01
Annex B Test Uncertainty
The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.
Uncertainty of Conducted Emission Measurement
Measuring Uncertainty for 9kHz-150kHz
a Level of Confidence of 150kHz-30MHz
95%(U=2Uc(y))
±4.1 dB
±3.7dB
Uncertainty of Radiated Emission Measurement
Measuring Uncertainty for 30MHz-200MHz
a Level of Confidence of 200MHz-1000MHz
95%(U=2Uc(y))
1GHz-6GHz
6GHz-18GHz
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
±5.06dB
±5.24dB
±5.18dB
±5.48dB
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 16 0f 18
REPORT No.:SZ17110212E01
Annex C Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory
Company Name:
Shenzhen Morlab Communications Technology Co., Ltd.
Department:
Morlab Laboratory
Address:
FL.3, Building A, FeiYang Science Park, No.8 LongChang
Road, Block 67, BaoAn District, ShenZhen, GuangDong
Province, P. R. China
Responsible
Manager:
Test
Lab
Mr. Su Feng
Telephone:
+86 755 36698555
Facsimile:
+86 755 36698525
2. Identification of the Responsible Testing Location
Name:
Shenzhen Morlab Communications Technology Co., Ltd.
Morlab Laboratory
Address:
FL.3, Building A, FeiYang Science Park, No.8 LongChang
Road, Block 67, BaoAn District, ShenZhen, GuangDong
Province, P. R. China
3. Accreditation Certificate
Accredited Testing
Laboratory:
The FCC designation number is CN1192.
(Shenzhen Morlab Communications Technology Co., Ltd.)
4. Test Software Utilized
Model
Version Number
Producer
MORLAB EMCR V1.2
Version 1.0
MORLAB
TS+ -[ JS32-CE]
Version2.5.0.0
Tonscend
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 17 0f 18
REPORT No.:SZ17110212E01
5. Test Equipments Utilized
Description
MXE EMI
Receiver
Manufacturer
Model
Serial No.
Cal. Date
Due. Date
Agilent
N9038A
MY54130016
2017.05.17
2018.05.16
Receiver
KEYSIGHT
N9038A
MY56400093
2017.07.13
2018.07.12
LISN
Schwarzbeck
NSLK 8127
812744
2017.05.17
2018.05.16
VTSD
9561D
9537
2017.05.17
2018.05.16
Schwarzbeck
VULB 9163
9163-519
2017.05.14
2018.05.13
CRT
9m*6m*6m
N/A
2017.11.19
2020.11.18
Pulse Limiter
(20dB)
Test Antenna Bi-Log
Semi-Anechoic
Chamber
END OF REPORT
MORLAB
SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China
Tel: 86-755-36698555
Fax: 86-755-36698525
Http://www.morlab.cn
E-mail: service@morlab.cn
Page 18 0f 18
Download: 0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Mirror Download [FCC.gov]0YX0ML01065 Ultralight P&C; Multireader MF+ Test Report CE RF Y Soft Corporation, a.s.
Document ID3770182
Application IDeH+va5BnvEaPHcrd+1NyCw==
Document DescriptionTest Report_JAB
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize54.97kB (687168 bits)
Date Submitted2018-03-06 00:00:00
Date Available2018-03-08 00:00:00
Creation Date2018-03-05 13:32:18
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2018-03-05 13:33:08
Document TitleCE RF TEST REPORT
Document CreatorAcrobat PDFMaker 9.1 Word 版
Document Author: X

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : X
Company                         : Microsoft
Create Date                     : 2018:03:05 13:32:18+08:00
KSO Product Build Ver           : 2052-9.1.0.4855
Modify Date                     : 2018:03:05 13:33:08+08:00
Source Modified                 : D:20180305033906
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2018:03:05 13:33:08+08:00
Creator Tool                    : Acrobat PDFMaker 9.1 Word 版
Document ID                     : uuid:3cbbbb5a-4c64-4740-b8f6-4ddc6dfea0ea
Instance ID                     : uuid:0293f2ca-b5bf-4e4d-9417-db93e79ee206
Subject                         : 105
Format                          : application/pdf
Title                           : CE RF TEST REPORT
Creator                         : X
Producer                        : Adobe PDF Library 9.0
Page Layout                     : OneColumn
Page Count                      : 18