FCC ID XWI-CS2992014

iHelp

by Wearable Health Solutions. Inc.

Grantee Code: XWI   Product Code: CS2992014
Latest application date: 2014-11-16

FCC ID Device Details

FCC IDXWI-CS2992014
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXWI
Product CodeCS2992014
Applicant BusinessWearable Health Solutions. Inc. 🇺🇸
Related Domains medalarmco.com
Equipment ClassiHelp
Test FirmSGS-CSTC Standards Technical Services Co.,Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2014-11-16

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2014-11-16PDF 665.4 KB
CS299B-A_Internal Photos-FCC-IInternal Photos2014-11-16PDF 3.2 MB
CS299B-A_Internal Photos-FCC-IIInternal Photos2014-11-16PDF 5.1 MB
CS299B-A_Internal Photos-FCC-IIIInternal Photos2014-11-16PDF 1.9 MB
CS299B-A_External Photos-FCCExternal Photos2014-11-16PDF 1.8 MB
Label & LocationID Label/Location Info2014-11-16PDF 87.6 KB
CS299B-A_Test Setup photos-FCCTest Setup Photos2014-11-16PDF 478.5 KB
SHEM1406001380RFV00--FCC Part 22&24-Rev 2.0Test Report2014-11-16PDF 1 MB
Confidentiality LetterCover Letter(s)2014-11-16PDF 1 MB
POA LetterCover Letter(s)2014-11-16PDF 313.7 KB
Confidential_Tune Up Procedure for Mobile PhoneParts List/Tune Up Info2014-11-16PDF 12.7 KB
OET Inquiry System Inquiry Tracking Number 793011RF Exposure Info2014-11-16PDF 172.6 KB
SAR report-Rev1RF Exposure Info2014-11-16PDF 4.4 MB
Confidential_Block Diagram for Module Metadata onlyBlock DiagramPDF 19.7 KB
Confidential_Block Diagram for Unit--Rev 2.0 Metadata onlyBlock DiagramPDF 22.1 KB
Confidential_Schematics for Module Metadata onlySchematicsPDF 198.3 KB
Confidential_Schematics for Unit Metadata onlySchematicsPDF 232.3 KB
Confidential_Operation Description-Rev 2.0 Metadata onlyOperational DescriptionPDF 13.5 KB
Confidential_SIM900 Datesheet Metadata onlyOperational DescriptionPDF 307.6 KB
Declaration Letter about Difference of Products-Rev 2.0 Metadata onlyOperational DescriptionPDF 76.2 KB

Application Information

Application IDEUT8BnrK0fFtLNOZ76J8ow==
Final Action Date2014-11-16
Application PurposeOriginal Equipment
Applicant FRN0025510488
ModelCS2992014
Frequency Range824.2-848.8 MHz
Equipment ClassPCT - PCS Licensed Transmitter worn on body
Device DescriptioniHelp
Responsible PartyRonnie Adams, CEO, ronnie@medalarmco.com , 877-498-2929
AgentEddy Eddy Eddy, SGS-CSTC Standards Technical Services (Shanghai), eddy.zong@sgs.com , 86-20-61915664
Technical ContactEddy Zong, SGS-CSTC Standards Technical Services (Shanghai), eddy.zong@sgs.com , 86-20-61915664
Test FirmZenger Zhang, SGS-CSTC Standards Technical Services Co.,Ltd., zenger.zhang@sgs.com , 86(0)2161915654
TCB Emailhotline@acbcert.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips that have no metallic component in the assembly and which provide at least 5 mm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.73W/kg; Body-worn 1.39 W/kg.

Applications

Application IDDatePurpose
EUT8BnrK0fFtLNOZ76J8ow==2014-11-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.2-848.8 MHz0.7111.19ppm246KGXW22HBC
1850.2-1909.8 MHz0.5520.53ppm248KGXW24EBC

Grants

TCB Grant - Application EUT8BnrK0fFtLNOZ76J8ow==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 11/16/2014

Application Dated: 11/14/2014
Wearable Health Solutions. Inc.
200 W Church Road
Suite B
King of Prussia, PA 19406
 
Attention: Ronnie Adams , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XWI-CS2992014
Name of Grantee:  Wearable Health Solutions. Inc.
Equipment Class: PCS Licensed Transmitter worn on body
Notes: iHelp
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 0.711 1.19  PM 246KGXW
BC 24E 1850.2  -  1909.8 0.552 0.53  PM 248KGXW

Power Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips that have no metallic component in the assembly and which provide at least 5 mm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.73W/kg; Body-worn 1.39 W/kg.

BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

EAS Grant - Application EUT8BnrK0fFtLNOZ76J8ow==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Wearable Health Solutions. Inc.
200 W Church Road Suite B
King of Prussia, PA 19406
United States
  Date of Grant: 11/16/2014

Application Dated: 11/14/2014
 
Attention: Ronnie Adams , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XWI-CS2992014
Name of Grantee:  Wearable Health Solutions. Inc.
Equipment Class: PCS Licensed Transmitter worn on body
Notes: iHelp
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.2  -  848.8 0.711 1.19  PM 246KGXW
BC 24E 1850.2  -  1909.8 0.552 0.53  PM 248KGXW

Power Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips that have no metallic component in the assembly and which provide at least 5 mm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Head: 0.73W/kg; Body-worn 1.39 W/kg.


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To: