FCC ID XYH-RPX4500V
VHF PORTABLE TRANSCEIVER
by RCA Communications Systems
Grantee Code: XYH Product Code: RPX4500V
Latest application date: 2015-08-10
FCC ID Device Details
| FCC ID | XYH-RPX4500V |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | XYH |
| Product Code | RPX4500V |
| Applicant Business | RCA Communications Systems 🇺🇸 |
| Related Domains | |
| Equipment Class | VHF PORTABLE TRANSCEIVER |
| Test Firm | EMC Technologies NZ Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 150-174 MHz | Change in identification of presently authorized equipment. Original FCC ID: STZSRP9170AC Grant Date: 11/10/2009 | 2015-08-10 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External photos - model RPX4500V Metadata only | External Photos | 2015-08-10 | PDF 328.1 KB |
| External photos updated - Model RPX4600V | External Photos | 2015-08-10 | PDF 832.9 KB |
| External photos updated- Model RPX4500V | External Photos | 2015-08-10 | PDF 248.3 KB |
| External photos- model RPX4600V Metadata only | External Photos | 2015-08-10 | PDF 341.4 KB |
| Label sample and location - model RPX4500V Metadata only | ID Label/Location Info | 2015-08-10 | PDF 331 KB |
| Label sample and location - model RPX4600V Metadata only | ID Label/Location Info | 2015-08-10 | PDF 344.4 KB |
| Label sample and location updated - RPX4500V Metadata only | ID Label/Location Info | 2015-08-10 | PDF 331 KB |
| Label sample and location updated - RPX4600V Metadata only | ID Label/Location Info | 2015-08-10 | PDF 344.4 KB |
| Updated Label sample and location - model RPX4500V | ID Label/Location Info | 2015-08-10 | PDF 251.3 KB |
| Updated Label sample and location - model RPX4600V | ID Label/Location Info | 2015-08-10 | PDF 835.9 KB |
| Cover letter explaining purpose of application | Cover Letter(s) | 2015-08-10 | PDF 252.9 KB |
| Frequency Justification Letter | Cover Letter(s) | 2015-08-10 | PDF 157.1 KB |
| Permission letter | Cover Letter(s) | 2015-08-10 | PDF 112.7 KB |
Application Information
| Application ID | 59og29YBAOkGqsN4qtd4mg== |
|---|---|
| Final Action Date | 2015-08-10 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: STZSRP9170AC Grant Date: 11/10/2009 |
| Applicant FRN | 0019356328 |
| Model | RPX4500V |
| Frequency Range | 150-174 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | VHF PORTABLE TRANSCEIVER |
| Responsible Party | Ben Burns, CEO, products@rcacommunicationssystems.com |
| Test Firm | Andrew Cutler, EMC Technologies NZ Ltd., auklab@ihug.co.nz |
| TCB Email | tei@timcoengr.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is rated maximum conducted. Nominal conducted output power is 4.8 Watts per 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn operating configuration is limited to the specific belt-clip supplied for use with this product that provides at least 1 cm separation between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. (Original grant 11/10/2009) The highest reported SAR values are - Head: 1.34 W/kg; Body-worn: 1.98 W/kg , Body Worn with Holster: 2.17 W/kg. accounting for a 50% duty cycle. (Date: 11/10/2009) Class II Change: Adds speaker microphone with attached antenna. Highest reported SAR Values: Head, body-worn accessories are: 0.99 mW/g and 1.03 mW/g respectively accounting for a 50% duty cycle. (Class II Permissive Change 10/05/2011) |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 59og29YBAOkGqsN4qtd4mg== | 2015-08-10 | Change in identification of presently authorized equipment. Original FCC ID: STZSRP9170AC Grant Date: 11/10/2009 |
Equipment Authorization
Grants
TCB Grant - Application 59og29YBAOkGqsN4qtd4mg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 08/10/2015 Application Dated: 08/10/2015 |
| RCA Communications Systems |
| 555 W. Victoria Street |
| Compton, CA 90220 |
| Attention: Ben Burns , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XYH-RPX4500V |
| Name of Grantee: | RCA Communications Systems |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | VHF PORTABLE TRANSCEIVER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 11K2F3E |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 11K2F1D |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 8K10F1E |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 16K0F3E |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 16K0F1D |
| Power listed is rated maximum conducted. Nominal conducted output power is 4.8 Watts per 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn operating configuration is limited to the specific belt-clip supplied for use with this product that provides at least 1 cm separation between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. (Original grant 11/10/2009) The highest reported SAR values are - Head: 1.34 W/kg; Body-worn: 1.98 W/kg , Body Worn with Holster: 2.17 W/kg. accounting for a 50% duty cycle. (Date: 11/10/2009) Class II Change: Adds speaker microphone with attached antenna. Highest reported SAR Values: Head, body-worn accessories are: 0.99 mW/g and 1.03 mW/g respectively accounting for a 50% duty cycle. (Class II Permissive Change 10/05/2011) |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
EAS Grant - Application 59og29YBAOkGqsN4qtd4mg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
RCA Communications Systems 555 W. Victoria Street Compton, CA 90220 United States |
Date of Grant: 08/10/2015 Application Dated: 08/10/2015 |
| Attention: Ben Burns , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | XYH-RPX4500V |
| Name of Grantee: | RCA Communications Systems |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | VHF PORTABLE TRANSCEIVER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 11K2F3E |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 11K2F1D |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 8K10F1E |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 16K0F3E |
| EF | 22, 90 | 150.0 - 174.0 | 5.0 | 5.0 PM | 16K0F1D |
| Power listed is rated maximum conducted. Nominal conducted output power is 4.8 Watts per 90.205(s). This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn operating configuration is limited to the specific belt-clip supplied for use with this product that provides at least 1 cm separation between the device and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. (Original grant 11/10/2009) The highest reported SAR values are - Head: 1.34 W/kg; Body-worn: 1.98 W/kg , Body Worn with Holster: 2.17 W/kg. accounting for a 50% duty cycle. (Date: 11/10/2009) Class II Change: Adds speaker microphone with attached antenna. Highest reported SAR Values: Head, body-worn accessories are: 0.99 mW/g and 1.03 mW/g respectively accounting for a 50% duty cycle. (Class II Permissive Change 10/05/2011) |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| Mail To: |