FCC ID XZB-MAXR900

900MHz WLAN mini-PCI card

by Arada Systems, Inc

Grantee Code: XZB   Product Code: MAXR900
Latest application date: 2011-01-19

FCC ID Device Details

FCC IDXZB-MAXR900
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeXZB
Product CodeMAXR900
Applicant BusinessArada Systems, Inc 🇺🇸
Related Domains aradasystems.com
Equipment Class900MHz WLAN mini-PCI card
Test FirmSporton International Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
907-922 MHzOriginal Equipment2011-01-19

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2011-01-19PDF 46.5 KB
internal photosInternal Photos2011-01-19PDF 1.8 MB
external photosExternal Photos2011-01-19PDF 1.8 MB
labelID Label/Location Info2011-01-19PDF 117.3 KB
test setup photosTest Setup Photos2011-01-19PDF 1,000.1 KB
test reportTest Report2011-01-19PDF 3.4 MB
DoC letterCover Letter(s)2011-01-19PDF 302.1 KB
LMA letterCover Letter(s)2011-01-19PDF 418.8 KB
authorizationCover Letter(s)2011-01-19PDF 318.5 KB
confidential letterCover Letter(s)2011-01-19PDF 361.4 KB
MPERF Exposure Info2011-01-19PDF 19.3 KB

Application Information

Application IDFNfakSemlmonZIqaeVU6bw==
Final Action Date2011-01-19
Application PurposeOriginal Equipment
Applicant FRN0019372309
Model-MAXR900
Frequency Range907-922 MHz
Equipment ClassDTS - Digital Transmission System
Device Description900MHz WLAN mini-PCI card
Responsible PartyPraveen Singh, psingh@aradasystems.com , 4087739298
AgentWayne Wayne Wayne, Sporton International Inc., wayne@sporton.com.tw , 886-3-3273456
Test FirmAlex Chen, Sporton International Inc., alex@sporton.com.tw , 886-3-327-3456
TCB Emailbrandhorst.dirk@phoenix-testlab.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentLimited Single Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is peak conducted. This OEM module is approved for use in products operating as fixed or mobile transmitting device. The only antennas approved for use with this module are those documented in the filing, and must be installed in the manner specified therein. This device incl. it's antenna must be operated with a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Grantee shall provide installation and operating instructions for satisfying RF exposure requirements to OEM integrators and installers. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device.

Applications

Application IDDatePurpose
FNfakSemlmonZIqaeVU6bw==2011-01-19Original Equipment

Equipment Authorization

FrequencyOutputRules
907-922 MHz0.2415C
912-917 MHz0.22915C

Grants

TCB Grant - Application FNfakSemlmonZIqaeVU6bw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PHOENIX TESTLAB GmbH
Koenigswinkel 10
32825 Blomberg,
Germany
Date of Grant: 01/19/2011

Application Dated: 01/19/2011
Arada Systems, Inc
4633 Old Ironsides Drive
Suite 415
Santa Clara, CA 95054
 
Attention: Praveen Singh

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XZB-MAXR900
Name of Grantee:  Arada Systems, Inc
Equipment Class: Digital Transmission System
Notes: 900MHz WLAN mini-PCI card
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 907.0  -  922.0 0.24  
15C 912.0  -  917.0 0.229  

Output power listed is peak conducted. This OEM module is approved for use in products operating as fixed or mobile transmitting device. The only antennas approved for use with this module are those documented in the filing, and must be installed in the manner specified therein. This device incl. it's antenna must be operated with a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Grantee shall provide installation and operating instructions for satisfying RF exposure requirements to OEM integrators and installers. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device.

EAS Grant - Application FNfakSemlmonZIqaeVU6bw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Arada Systems, Inc
4633 Old Ironsides Drive Suite 415P.O. Box ,
Santa Clara, CA 95054
United States
  Date of Grant: 01/19/2011

Application Dated: 01/19/2011
 
Attention: Praveen Singh

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  XZB-MAXR900
Name of Grantee:  Arada Systems, Inc
Equipment Class: Digital Transmission System
Notes: 900MHz WLAN mini-PCI card
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 907.0  -  922.0 0.24  
15C 912.0  -  917.0 0.229  

Output power listed is peak conducted. This OEM module is approved for use in products operating as fixed or mobile transmitting device. The only antennas approved for use with this module are those documented in the filing, and must be installed in the manner specified therein. This device incl. it's antenna must be operated with a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Grantee shall provide installation and operating instructions for satisfying RF exposure requirements to OEM integrators and installers. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device.