FCC ID Y3D-RED4

RFID Module

by Phychips Inc.

Grantee Code: Y3D   Product Code: RED4
Latest application date: 2017-04-11

Device Images

FCC ID Device Details

FCC IDY3D-RED4
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeY3D
Product CodeRED4
Applicant BusinessPhychips Inc. 🇰🇷
Related Domains phychips.com
Equipment ClassRFID Module
Test FirmDT&C; Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
917.1-926.9 MHzOriginal Equipment2017-04-11

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2017-10-08PDF 539.6 KB
Internal PhotosInternal Photos2017-10-08PDF 274.9 KB
External PhotosExternal Photos2017-10-08PDF 737.3 KB
Product LabelID Label/Location Info2017-04-11PDF 69.8 KB
Test Setup PhotosTest Setup Photos2017-10-08PDF 681.6 KB
DSS Test ReportTest Report2017-04-11PDF 3.4 MB
Antenna Attestation LetterAttestation Statements2017-04-11PDF 167.7 KB
Confidentiality Request LetterCover Letter(s)2017-04-11PDF 99.9 KB
Modular Approval LetterCover Letter(s)2017-04-11PDF 137.6 KB
PoACover Letter(s)2017-04-11PDF 88.8 KB
Product Certification Representative Auth LetterCover Letter(s)2017-04-11PDF 90.5 KB
MPE CalculationRF Exposure Info2017-04-11PDF 67.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 78.1 KB
Schematics Metadata onlySchematicsPDF 97.4 KB
Operational Description Metadata onlyOperational DescriptionPDF 585.8 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 195.3 KB

Application Information

Application IDztwRaQ+Ge7MUh4ZHPHJv6w==
Final Action Date2017-04-11
Application PurposeOriginal Equipment
Applicant FRN0020381604
ModelRED4
Frequency Range917.1-926.9 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionRFID Module
Responsible PartyKhyungjoo Min, Principal Research Engineer, kjmin@phychips.com , +82-42-864-2402
Test FirmWonJung Lee, DT&C; Co., Ltd., leewj@dtnc.net , 82-31-321-2664
TCB Emailtcb@siemic.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date10/08/2017
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentLimited Single Modular Approval
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsModular Approval. Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
ztwRaQ+Ge7MUh4ZHPHJv6w==2017-04-11Original Equipment

Equipment Authorization

FrequencyOutputRules
917.1-926.9 MHz0.333000015C

Grants

TCB Grant - Application ztwRaQ+Ge7MUh4ZHPHJv6w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
775 Montague Expressway
Milpitas, CA 95035
Date of Grant: 04/11/2017

Application Dated: 04/11/2017
Phychips Inc.
(Yongsan-dong), Migun Technoworld 2, A-104, 187,
Techno 2-ro, Yuseong-gu,
Daejeon,,
South Korea
 
Attention: Khyungjoo Min , Principal Research Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Y3D-RED4
Name of Grantee:  Phychips Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: RFID Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 917.1  -  926.9 0.333  

Modular Approval. Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application ztwRaQ+Ge7MUh4ZHPHJv6w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Phychips Inc.
(Yongsan-dong), Migun Technoworld 2, A-104, 187, Techno 2-ro, Yuseong-gu,
Daejeon,,
South Korea
  Date of Grant: 04/11/2017

Application Dated: 04/11/2017
 
Attention: Khyungjoo Min , Principal Research Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Y3D-RED4
Name of Grantee:  Phychips Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: RFID Module
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 917.1  -  926.9 0.333  

Modular Approval. Power listed is the maximum conducted output power. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. OEM integrators and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: