FCC ID Y7HXZBWE

Radio transmitter for sensors and switches and programmable receiver using ZigBee Green Power protocol

by Schneider Electric Industries France L'Isle d'Espagnac

Grantee Code: Y7H   Product Code: XZBWE
Latest application date: 2021-12-01

FCC ID Device Details

FCC IDY7HXZBWE
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeY7H
Product CodeXZBWE
Applicant BusinessSchneider Electric Industries France L'Isle d'Espagnac 🇫🇷
Related Domains schneider-electric.com
Equipment ClassRadio transmitter for sensors and switches and programmable receiver using ZigBee Green Power protocol
Test FirmEMITECH Angers

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405 MHzOriginal Equipment2021-12-01

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2021-12-01PDF 4.1 MB
Internal PhotosInternal Photos2021-12-31PDF 1.2 MB
External PhotosExternal Photos2021-12-01PDF 623.9 KB
Label InfoID Label/Location Info2021-12-01PDF 427.5 KB
Test Setup PhotosTest Setup Photos2021-12-01PDF 1.2 MB
Test ReportTest Report2021-12-01PDF 945.2 KB
SDoC AttestationLetterAttestation Statements2021-12-01PDF 65.7 KB
Confidentiality LetterCover Letter(s)2021-12-01PDF 145.8 KB
POA LetterCover Letter(s)2021-12-01PDF 156.5 KB
MPE ReportRF Exposure Info2021-12-01PDF 513.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 371.9 KB
Schematics Metadata onlySchematicsPDF 2.1 MB
Operational Description Metadata onlyOperational DescriptionPDF 638.3 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 843.6 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 285.5 KB

Application Information

Application IDEi6/v9ktq4WX/KMsY7UjuQ==
Final Action Date2021-12-01
Application PurposeOriginal Equipment
Applicant FRN0019796176
ModelXZBWE
Frequency Range2405 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionRadio transmitter for sensors and switches and programmable receiver using ZigBee Green Power protocol
Responsible PartyJean-Pierre LAIDET, Product Certification Manager, jean-pierre.laidet@schneider-electric.com , +33545372446
Test FirmMounir El Marzouki, EMITECH Angers, m.elmarzouki@emitech-group.com , 33-2-41-73-26-27
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date12/31/2021
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. Device must be installed and operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
Ei6/v9ktq4WX/KMsY7UjuQ==2021-12-01Original Equipment

Equipment Authorization

FrequencyOutputRules
2405 MHz0.000530015C

Grants

TCB Grant - Application Ei6/v9ktq4WX/KMsY7UjuQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 12/01/2021

Application Dated: 12/01/2021
Schneider Electric Industries France L'Isle d'Espagnac
BP 660 - ZI No.3
L'ISLE D'ESPAGNAC, 16340
France
 
Attention: Jean-Pierre LAIDET , Product Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Y7HXZBWE
Name of Grantee:  Schneider Electric Industries France L'Isle d'Espagnac
Equipment Class: Digital Transmission System
Notes: Radio transmitter for sensors and switches and programmable receiver using ZigBee Green Power protocol
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2405.0 0.00053  

Power listed is conducted. Device must be installed and operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application Ei6/v9ktq4WX/KMsY7UjuQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Schneider Electric Industries France L'Isle d'Espagnac
BP 660 - ZI No.3 P.O. Box ,
L'ISLE D'ESPAGNAC, 16340
France
  Date of Grant: 12/01/2021

Application Dated: 12/01/2021
 
Attention: Jean-Pierre LAIDET , Product Certification Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Y7HXZBWE
Name of Grantee:  Schneider Electric Industries France L'Isle d'Espagnac
Equipment Class: Digital Transmission System
Notes: Radio transmitter for sensors and switches and programmable receiver using ZigBee Green Power protocol
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2405.0 0.00053  

Power listed is conducted. Device must be installed and operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: