FCC ID YAMDS-6250U1
DMR Trunking Base Station
by Hytera Communications Corporation Limited
Grantee Code: YAM Product Code: DS6250U1
Latest application date: 2017-10-25
FCC ID Device Details
| FCC ID | YAMDS-6250U1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YAM |
| Product Code | DS6250U1 |
| Applicant Business | Hytera Communications Corporation Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | DMR Trunking Base Station |
| Test Firm | Bay Area Compliance Laboratories Corp. (Shenzhen) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 410-470 MHz | Original Equipment | 2017-10-25 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2017-10-25 | PDF 1.2 MB |
| Int Photos | Internal Photos | 2017-10-25 | PDF 624.6 KB |
| Ext Photos | External Photos | 2017-10-25 | PDF 431.1 KB |
| FCC ID Label | ID Label/Location Info | 2017-10-25 | PDF 139.5 KB |
| Test Report | Test Report | 2017-10-25 | PDF 1.5 MB |
| Attestation Letter | Attestation Statements | 2017-10-25 | PDF 19.3 KB |
| Confidentiality Letter | Cover Letter(s) | 2017-10-25 | PDF 23.2 KB |
| Frequency Justification Letter | Cover Letter(s) | 2017-10-25 | PDF 38.8 KB |
| POA | Cover Letter(s) | 2017-10-25 | PDF 18.8 KB |
| Block Diagram Metadata only | Block Diagram | PDF 188.1 KB | |
| Schematics Metadata only | Schematics | PDF 2.4 MB | |
| Operation Description Metadata only | Operational Description | PDF 378.2 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 226.7 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 80.3 KB |
Application Information
| Application ID | XjKeN4O2efZI1DomHYnTCQ== |
|---|---|
| Final Action Date | 2017-10-25 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0019701887 |
| Model | DS-6250U1 |
| Frequency Range | 410-470 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | DMR Trunking Base Station |
| Responsible Party | Tiantian Chen, Certification Engineer, tiantian.chen@hytera.com |
| Test Firm | John Chan, Bay Area Compliance Laboratories Corp. (Shenzhen), baclsz.regulatory@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is rated conducted at antenna port. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures and must be installed to provide the configurations and separation distances of 140 cm described in this filing. This transmitter must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. A label, as described in this filing must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. RF exposure compliance may be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3). |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| XjKeN4O2efZI1DomHYnTCQ== | 2017-10-25 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application XjKeN4O2efZI1DomHYnTCQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/25/2017 Application Dated: 10/25/2017 |
| Hytera Communications Corporation Limited |
| Hytera Tower, Hi-Tech Industrial Park North, |
| 9108# Beihuan Road, Nanshan District, |
| Shenzhen, 518057 China |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMDS-6250U1 |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | DMR Trunking Base Station |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF ES | 22, 74, 90 | 410.0 - 470.0 | 40.0 | 1.5 PM | 7K60F1E |
| EF ES | 22, 74, 90 | 410.0 - 470.0 | 40.0 | 1.5 PM | 7K60F1D |
| Output power listed is rated conducted at antenna port. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures and must be installed to provide the configurations and separation distances of 140 cm described in this filing. This transmitter must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. A label, as described in this filing must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. RF exposure compliance may be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3). |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| ES: | This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth. |
EAS Grant - Application XjKeN4O2efZI1DomHYnTCQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Limited Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China |
Date of Grant: 10/25/2017 Application Dated: 10/25/2017 |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMDS-6250U1 |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | DMR Trunking Base Station |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF ES | 22, 74, 90 | 410.0 - 470.0 | 40.0 | 1.5 PM | 7K60F1E |
| EF ES | 22, 74, 90 | 410.0 - 470.0 | 40.0 | 1.5 PM | 7K60F1D |
| Output power listed is rated conducted at antenna port. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures and must be installed to provide the configurations and separation distances of 140 cm described in this filing. This transmitter must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. A label, as described in this filing must be displayed on the device to direct users to the specific training information required for meeting RF exposure requirements. RF exposure compliance may be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of Section 1.1307(b)(3). |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| ES: | This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth. |
| Mail To: |