FCC ID YAMPD60XVHF

Digital Portable Radio

by Hytera Communications Corporation Limited

Grantee Code: YAM   Product Code: PD60XVHF
Latest application date: 2014-08-19

FCC ID Device Details

FCC IDYAMPD60XVHF
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYAM
Product CodePD60XVHF
Applicant BusinessHytera Communications Corporation Limited 🇨🇳
Related Domains hytera.com
Equipment ClassDigital Portable Radio
Test FirmBay Area Compliance Laboratory Corp. (Shenzhen)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
136-174 MHzClass II permissive change or modification of presently authorized equipment2014-08-19
136-174 MHzClass II permissive change or modification of presently authorized equipment2014-08-18
136-174 MHzOriginal Equipment2014-04-14

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2014-04-14PDF 477.3 KB
Int PhotosInternal Photos2014-08-19PDF 1,006.6 KB
Int PhotosInternal Photos2014-08-18PDF 999.3 KB
Internal PhotosInternal Photos2014-04-14PDF 776.1 KB
Ext PhotosExternal Photos2014-08-19PDF 505.3 KB
Ext PhotosExternal Photos2014-08-18PDF 401.4 KB
Ext PhotosExternal Photos2014-04-14PDF 413.5 KB
FCC ID LabelID Label/Location Info2014-08-19PDF 102.6 KB
FCC ID LabelID Label/Location Info2014-08-18PDF 48.6 KB
FCC ID LabelID Label/Location Info2014-04-14PDF 118.1 KB
Setup PhotosTest Setup Photos2014-08-19PDF 151.1 KB
Setup PhotosTest Setup Photos2014-08-18PDF 153.5 KB
Setup PhotosTest Setup Photos2014-04-14PDF 195 KB
Test ReportTest Report2014-08-19PDF 215.1 KB
Test ReportTest Report2014-08-18PDF 214.8 KB
Test ReportTest Report2014-04-14PDF 717 KB
CIIPC LetterCover Letter(s)2014-08-19PDF 18.3 KB
Frequency Justification LetterCover Letter(s)2014-08-19PDF 21.4 KB
POACover Letter(s)2014-08-19PDF 58.8 KB
CIIPC LetterCover Letter(s)2014-08-18PDF 18.5 KB
Confidentiality LetterCover Letter(s)2014-08-18PDF 22.5 KB
Frequency Justiificatio LetterCover Letter(s)2014-08-18PDF 21.4 KB
POACover Letter(s)2014-08-18PDF 116 KB
Confidentiality LetterCover Letter(s)2014-04-14PDF 63.2 KB
Frequency Justification LetterCover Letter(s)2014-04-14PDF 62.1 KB
POACover Letter(s)2014-04-14PDF 59.3 KB
SAR ReportRF Exposure Info2014-08-19PDF 2.2 MB
SAR ReportRF Exposure Info2014-08-18PDF 2 MB
SAR ReportRF Exposure Info2014-04-14PDF 4 MB
Block Diagram Metadata onlyBlock DiagramPDF 90.4 KB
Schematics Metadata onlySchematicsPDF 495.3 KB
Schmeatics Metadata onlySchematicsPDF 484.2 KB
Circuit Description Metadata onlyOperational DescriptionPDF 775.6 KB
KDB Approval Metadata onlyOperational DescriptionPDF 42.4 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 98.1 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 155.5 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 113.4 KB

Application Information

Application IDYhzXVOMIP2JTS7MxaWwNiQ==
Final Action Date2014-08-19
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0019701887
ModelPD60XVHF
Frequency Range136-174 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionDigital Portable Radio
Responsible PartyTiantian Chen, Certification Engineer, tiantian.chen@hytera.com , +86-755-26972999
Test FirmJohn Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com , 08675533320018
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 5.93 Watts. This device must be restricted to work-related operations only in an occupational/controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Push-to-Talk and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing, the separation distance between user and the device or its antenna shall be at least 2.5 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational/controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. The highest reported SAR values for Face held and body-worn accessory across all filings are 0.74 W/Kg and 1.43 W/Kg respectively when operating at 50% duty cycle. Class II Permissive Change as documented in this filing.

Applications

Application IDDatePurpose
YhzXVOMIP2JTS7MxaWwNiQ==2014-08-19Class II permissive change or modification of presently authorized equipment
wsYaBYVD1H0XWxG/bJKtNA==2014-08-18Class II permissive change or modification of presently authorized equipment
PnGbIX82TM9wYOIK816P7w==2014-04-14Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
136-174 MHz50.25ppm11K0F3E22, 74, 80, 9BF, EF
136-174 MHz50.25ppm7K60FXD22, 74, 80, 9BF, EF
136-174 MHz50.25ppm7K60FXW22, 74, 80, 9BF, EF

Grants

TCB Grant - Application YhzXVOMIP2JTS7MxaWwNiQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 08/19/2014

Application Dated: 08/19/2014
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD60XVHF
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Digital Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 11K0F3E
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXD
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXW

Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 5.93 Watts. This device must be restricted to work-related operations only in an occupational/controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Push-to-Talk and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing, the separation distance between user and the device or its antenna shall be at least 2.5 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational/controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. The highest reported SAR values for Face held and body-worn accessory across all filings are 0.74 W/Kg and 1.43 W/Kg respectively when operating at 50% duty cycle. Class II Permissive Change as documented in this filing.

BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application YhzXVOMIP2JTS7MxaWwNiQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 08/19/2014

Application Dated: 08/19/2014
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD60XVHF
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Digital Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 11K0F3E
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXD
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXW

Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 5.93 Watts. This device must be restricted to work-related operations only in an occupational/controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Push-to-Talk and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing, the separation distance between user and the device or its antenna shall be at least 2.5 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational/controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. The highest reported SAR values for Face held and body-worn accessory across all filings are 0.74 W/Kg and 1.43 W/Kg respectively when operating at 50% duty cycle. Class II Permissive Change as documented in this filing.


BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

TCB Grant - Application wsYaBYVD1H0XWxG/bJKtNA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 08/18/2014

Application Dated: 08/18/2014
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD60XVHF
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Digital Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 11K0F3E
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXD
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXW

Class II Permissive Change as documented in this filing. Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 5.93 Watts. This device must be restricted to work-related operations only in an occupational/controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Push-to-Talk and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing, the separation distance between user and the device or its antenna shall be at least 2.5 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational/controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. The highest reported SAR values for Face held and body-worn accessory across all filings are 0.74 W/Kg and 1.43 W/Kg respectively when operating at 50% duty cycle.

BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application wsYaBYVD1H0XWxG/bJKtNA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 08/18/2014

Application Dated: 08/18/2014
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD60XVHF
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Digital Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 11K0F3E
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXD
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXW

Class II Permissive Change as documented in this filing. Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 5.93 Watts. This device must be restricted to work-related operations only in an occupational/controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Push-to-Talk and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing, the separation distance between user and the device or its antenna shall be at least 2.5 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational/controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. The highest reported SAR values for Face held and body-worn accessory across all filings are 0.74 W/Kg and 1.43 W/Kg respectively when operating at 50% duty cycle.


BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

TCB Grant - Application PnGbIX82TM9wYOIK816P7w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 04/14/2014

Application Dated: 04/14/2014
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD60XVHF
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Digital Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 11K0F3E
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXD
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXW

Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 5.93 Watts. This device must be restricted to work-related operations only in an occupational/controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Push-to-Talk and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing, the separation distance between user and the device or its antenna shall be at least 2.5 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational/controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. The highest reported SAR values for Face held and body-worn accessory are 0.74 W/Kg and 1.43 W/Kg respectively when operating at 50% duty cycle.

BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application PnGbIX82TM9wYOIK816P7w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 04/14/2014

Application Dated: 04/14/2014
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD60XVHF
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: Digital Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 11K0F3E
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXD
BF EF 22, 74, 80, 90 136.0  -  174.0 5.0 0.25  PM 7K60FXW

Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 5.93 Watts. This device must be restricted to work-related operations only in an occupational/controlled RF exposure environment and must operate with a duty factor not exceeding 50%. This transmitter may operate with the antenna(s) documented in this filing in Push-to-Talk and body-worn configurations. RF exposure compliance is limited to the specific belt-clip and accessory configurations as documented in this filing, the separation distance between user and the device or its antenna shall be at least 2.5 cm. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with occupational/controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting occupational exposure requirements. The highest reported SAR values for Face held and body-worn accessory are 0.74 W/Kg and 1.43 W/Kg respectively when operating at 50% duty cycle.


BF: The output power is continuously variable from the value listed in this entry to 20%-25% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

Mail To: