FCC ID YAMPD79XEX
Ex Digital Radio
by Hytera Communications Corporation Limited
Grantee Code: YAM Product Code: PD79XEX
Latest application date: 2015-02-27
FCC ID Device Details
| FCC ID | YAMPD79XEX |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YAM |
| Product Code | PD79XEX |
| Applicant Business | Hytera Communications Corporation Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | Ex Digital Radio |
| Test Firm | Bay Area Compliance Laboratory Corp. (Shenzhen) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 400-406 MHz | Class II permissive change or modification of presently authorized equipment | 2015-02-27 |
| 400-406 MHz | Class II permissive change or modification of presently authorized equipment | 2014-03-20 |
| 400-406 MHz | Original Equipment | 2012-01-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2015-02-27 | PDF 742 KB |
| Users Manual | Users Manual | 2012-01-23 | PDF 745.4 KB |
| Int Photos | Internal Photos | 2015-02-27 | PDF 809.8 KB |
| Internal Photos | Internal Photos | 2012-01-23 | PDF 749.2 KB |
| Ext Photos | External Photos | 2015-02-27 | PDF 385.6 KB |
| External Photos | External Photos | 2014-03-20 | PDF 589.5 KB |
| External Photos | External Photos | 2012-01-23 | PDF 514.5 KB |
| FCC ID Label | ID Label/Location Info | 2015-02-27 | PDF 164.7 KB |
| ID Label/Location | ID Label/Location Info | 2012-01-23 | PDF 176.8 KB |
| Test Setup Photos | Test Setup Photos | 2012-01-23 | PDF 554.1 KB |
| Test Report | Test Report | 2015-02-27 | PDF 181.6 KB |
| Test Report | Test Report | 2012-01-23 | PDF 3.8 MB |
| Attestation Letter | Attestation Statements | 2015-02-27 | PDF 17.5 KB |
| Cover Letter | Cover Letter(s) | 2012-01-23 | PDF 48.9 KB |
| Class II Permissive Change Letter | Cover Letter(s) | 2015-02-27 | PDF 35.6 KB |
| Confidentiality Letter | Cover Letter(s) | 2015-02-27 | PDF 22.7 KB |
| POA | Cover Letter(s) | 2015-02-27 | PDF 18.6 KB |
| Product Similarity Declaration | Cover Letter(s) | 2015-02-27 | PDF 18 KB |
| Authorization Letter | Cover Letter(s) | 2014-03-20 | PDF 44.7 KB |
| Class II Change Letter | Cover Letter(s) | 2014-03-20 | PDF 39.9 KB |
| Confidentiality letter | Cover Letter(s) | 2014-03-20 | PDF 36 KB |
| Cover Letter | Cover Letter(s) | 2014-03-20 | PDF 19.9 KB |
| Confidentiality Letter | Cover Letter(s) | 2012-01-23 | PDF 41.8 KB |
| Justification Letter | Cover Letter(s) | 2012-01-23 | PDF 47.1 KB |
| SAR Report | RF Exposure Info | 2015-02-27 | PDF 3.4 MB |
| RF Exposure | RF Exposure Info | 2014-03-20 | PDF 3.6 MB |
| RF Exposure | RF Exposure Info | 2012-01-23 | PDF 4.1 MB |
| Schematics Metadata only | Schematics | PDF 509.9 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 462.4 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 277.9 KB |
Application Information
| Application ID | BAVplRQJwuazs19D5Yh9UA== |
|---|---|
| Final Action Date | 2015-02-27 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0019701887 |
| Model | PD79XEX |
| Frequency Range | 400-406 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | Ex Digital Radio |
| Responsible Party | Tiantian Chen, Certification Engineer, tiantian.chen@hytera.com |
| Test Firm | John Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change of removing the keypad and LCD display documented in this filing. Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 1.20 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing and must provide at least 2.5 cm separation between the device and the user's body. The highest reported SAR values across all filings are Head: 1.01 W/kg, Body-worn: 1.92 W/kg when operating at 50% duty cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| BAVplRQJwuazs19D5Yh9UA== | 2015-02-27 | Class II permissive change or modification of presently authorized equipment |
| 3Rgjsyzvr+gt/ItMCC8xZw== | 2014-03-20 | Class II permissive change or modification of presently authorized equipment |
| 0PgPuJ8a3aT2xLY8QehLUQ== | 2012-01-23 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 400-406 MHz | 1 | 1.22ppm | 11K0F3E | 22, 74, 80, 9 | EF |
| 400-406 MHz | 1 | 1.22ppm | 11K0F3E | 22, 74, 80, 9 | EF, ES |
| 400-406 MHz | 1 | 1.22ppm | 11K0F3E | 9 | EF |
| 400-406 MHz | 1 | 1.22ppm | 7K60FXD | 22, 74, 80, 9 | EF |
| 400-406 MHz | 1 | 1.22ppm | 7K60FXD | 22, 74, 80, 9 | EF, ES |
| 400-406 MHz | 1 | 1.22ppm | 7K60FXD | 9 | EF |
| 400-406 MHz | 1 | 1.22ppm | 7K60FXW | 22, 74, 80, 9 | EF |
| 400-406 MHz | 1 | 1.22ppm | 7K60FXW | 22, 74, 80, 9 | EF, ES |
| 400-406 MHz | 1 | 1.22ppm | 7K60FXW | 9 | EF |
| 406.1-470 MHz | 1 | 1.35ppm | 11K0F3E | 22, 74, 80, 9 | EF |
| 406.1-470 MHz | 1 | 1.35ppm | 11K0F3E | 22, 74, 80, 9 | EF, ES |
| 406.1-470 MHz | 1 | 1.35ppm | 11K0F3E | 9 | EF |
| 406.1-470 MHz | 1 | 1.36ppm | 7K60FXD | 22, 74, 80, 9 | EF |
| 406.1-470 MHz | 1 | 1.36ppm | 7K60FXD | 22, 74, 80, 9 | EF, ES |
| 406.1-470 MHz | 1 | 1.36ppm | 7K60FXD | 9 | EF |
| 406.1-470 MHz | 1 | 1.36ppm | 7K60FXW | 22, 74, 80, 9 | EF |
| 406.1-470 MHz | 1 | 1.36ppm | 7K60FXW | 22, 74, 80, 9 | EF, ES |
| 406.1-470 MHz | 1 | 1.36ppm | 7K60FXW | 9 | EF |
Grants
TCB Grant - Application BAVplRQJwuazs19D5Yh9UA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 02/27/2015 Application Dated: 02/27/2015 |
| Hytera Communications Corporation Limited |
| Hytera Tower, Hi-Tech Industrial Park North, |
| 9108# Beihuan Road, Nanshan District, |
| Shenzhen, 518057 China |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPD79XEX |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Ex Digital Radio |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF ES | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 11K0F3E |
| EF ES | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.35 PM | 11K0F3E |
| EF ES | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXD |
| EF ES | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXD |
| EF ES | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXW |
| EF ES | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXW |
| Class II Permissive Change of removing the keypad and LCD display documented in this filing. Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 1.20 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing and must provide at least 2.5 cm separation between the device and the user's body. The highest reported SAR values across all filings are Head: 1.01 W/kg, Body-worn: 1.92 W/kg when operating at 50% duty cycle. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| ES: | This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth. |
EAS Grant - Application BAVplRQJwuazs19D5Yh9UA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Limited Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China |
Date of Grant: 02/27/2015 Application Dated: 02/27/2015 |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPD79XEX |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Ex Digital Radio |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF ES | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 11K0F3E |
| EF ES | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.35 PM | 11K0F3E |
| EF ES | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXD |
| EF ES | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXD |
| EF ES | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXW |
| EF ES | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXW |
| Class II Permissive Change of removing the keypad and LCD display documented in this filing. Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 1.20 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing and must provide at least 2.5 cm separation between the device and the user's body. The highest reported SAR values across all filings are Head: 1.01 W/kg, Body-worn: 1.92 W/kg when operating at 50% duty cycle. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| ES: | This equipment is capable of supporting a minimum data rate of 4800 bits per second per 6.25 kHz of channel bandwidth. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
EMCCons DR RASEK GmbH & Co. KG Stoernhofer Berg 15 Unterleinleiter, 91364 Germany |
Date of Grant: 03/20/2014 Application Dated: 03/20/2014 |
| Hytera Communications Corporation Limited |
| Hytera Tower, Hi-Tech Industrial Park North, |
| 9108# Beihuan Road, Nanshan District, |
| Shenzhen, 518057 China |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPD79XEX |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Ex Digital Radio |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 11K0F3E |
| EF | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.35 PM | 11K0F3E |
| EF | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXD |
| EF | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXD |
| EF | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXW |
| EF | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXW |
| Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 1.20 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing and must provide at least 2.5 cm separation between the device and the user's body. The highest reported SAR values are: Head: 1.01 W/kg, Body-worn: 1.92 W/kg when operating at 50% duty cycle. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
EAS Grant - Application 3Rgjsyzvr+gt/ItMCC8xZw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Limited Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China |
Date of Grant: 03/20/2014 Application Dated: 03/20/2014 |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPD79XEX |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Ex Digital Radio |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 11K0F3E |
| EF | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.35 PM | 11K0F3E |
| EF | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXD |
| EF | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXD |
| EF | 22, 74, 80, 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXW |
| EF | 22, 74, 80, 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXW |
| Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 1.20 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing and must provide at least 2.5 cm separation between the device and the user's body. The highest reported SAR values are: Head: 1.01 W/kg, Body-worn: 1.92 W/kg when operating at 50% duty cycle. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
EMCCert Dr. Rasek GmbH Stoernhofer Berg 15 91364 Unterleinleiter, Germany |
Date of Grant: 01/23/2012 Application Dated: 01/23/2012 |
| Hytera Communications Corporation Ltd. |
| Hyt Tower, Hi-Tech Industrial Park North |
| Nanshan District, Shenzhen, 518057 China |
| Attention: Lei Xiong |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPD79XEX |
| Name of Grantee: | Hytera Communications Corporation Ltd. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Ex Digital Radio |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 11K0F3E |
| EF | 90 | 406.1 - 470.0 | 1.0 | 1.35 PM | 11K0F3E |
| EF | 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXD |
| EF | 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXD |
| EF | 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXW |
| EF | 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXW |
| Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 1.20 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing and must provide at least 2.5 cm separation between the device and the user's body. The highest reported SAR values are: Head: 0.94 W/kg, Body-worn: 1.92 W/kg when operating at 50% duty cycle. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
EAS Grant - Application 0PgPuJ8a3aT2xLY8QehLUQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Ltd. Hyt Tower, Hi-Tech Industrial Park North Nanshan District, Shenzhen, 518057 China |
Date of Grant: 01/23/2012 Application Dated: 01/23/2012 |
| Attention: Lei Xiong |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPD79XEX |
| Name of Grantee: | Hytera Communications Corporation Ltd. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | Ex Digital Radio |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EF | 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 11K0F3E |
| EF | 90 | 406.1 - 470.0 | 1.0 | 1.35 PM | 11K0F3E |
| EF | 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXD |
| EF | 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXD |
| EF | 90 | 400.0 - 406.0 | 1.0 | 1.22 PM | 7K60FXW |
| EF | 90 | 406.1 - 470.0 | 1.0 | 1.36 PM | 7K60FXW |
| Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 1.20 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing and must provide at least 2.5 cm separation between the device and the user's body. The highest reported SAR values are: Head: 0.94 W/kg, Body-worn: 1.92 W/kg when operating at 50% duty cycle. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |