FCC ID YAMPD98XU5

Digital Portable Radio

by Hytera Communications Corporation Limited

Grantee Code: YAM   Product Code: PD98XU5
Latest application date: 2017-11-02

FCC ID Device Details

FCC IDYAMPD98XU5
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYAM
Product CodePD98XU5
Applicant BusinessHytera Communications Corporation Limited 🇨🇳
Related Domains hytera.com
Equipment ClassDigital Portable Radio
Test FirmBay Area Compliance Laboratories Corp. (Shenzhen)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
806-824 MHzOriginal Equipment2017-11-02
2402-2480 MHzOriginal Equipment2017-11-02
2402-2480 MHzOriginal Equipment2017-11-02

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2017-11-02PDF 639.9 KB
Int PhotosInternal Photos2017-11-02PDF 844.9 KB
Ext PhotosExternal Photos2017-11-02PDF 791.2 KB
FCC ID LabelID Label/Location Info2017-11-02PDF 107.6 KB
Setup PhotosTest Setup Photos2017-11-02PDF 217.8 KB
Test ReportTest Report2017-11-02PDF 526.3 KB
Test ReportTest Report2017-11-02PDF 2.2 MB
Test ReportTest Report2017-11-02PDF 1.1 MB
Confidentiality LetterCover Letter(s)2017-11-02PDF 23.2 KB
POACover Letter(s)2017-11-02PDF 18.8 KB
SAR Probe & Dipole Cal CertRF Exposure Info2017-11-02PDF 1.8 MB
SAR ReportRF Exposure Info2017-11-02PDF 696.7 KB
SAR Scan PlotsRF Exposure Info2017-11-02PDF 414.7 KB
SAR Setup PhotosRF Exposure Info2017-11-02PDF 436.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 127.6 KB
Schematics Metadata onlySchematicsPDF 424.1 KB
Schemtics Metadata onlySchematicsPDF 424.1 KB
Operation Description Metadata onlyOperational DescriptionPDF 813.9 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 177.2 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 78.7 KB

Application Information

Application IDsMggJIKQMZF1SyFHu4gcog==
Final Action Date2017-11-02
Application PurposeOriginal Equipment
Applicant FRN0019701887
ModelPD98XU5
Frequency Range806-824 MHz
Equipment ClassPCF - PCS Licensed Transmitter held to face
Device DescriptionDigital Portable Radio
Responsible PartyTiantian Chen, Certification Engineer, tiantian.chen@hytera.com , +86-755-26972999
Test FirmJohn Chan, Bay Area Compliance Laboratories Corp. (Shenzhen), baclsz.regulatory@baclcorp.com , 86-755-33320018
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is manufacturer’s rated power. Power is select-able between 1 W and 3 W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the specified accessories documented in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, and simultaneous transmission exposure conditions are 1.05 W/kg, 5.35 W/kg and 5.40 W/kg, respectively.

Applications

Application IDDatePurpose
sMggJIKQMZF1SyFHu4gcog==2017-11-02Original Equipment
ki4YfVzD2hcqE5N60bFRsg==2017-11-02Original Equipment
cdWgp6C9Vlf9lVEbwS95hw==2017-11-02Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
806-824 MHz31ppm7K60F1D9
806-824 MHz31ppm7K60F1E9
851-869 MHz31ppm16K0F3E9
851-869 MHz31ppm11K0F3E9
851-869 MHz31ppm7K60F1D9
851-869 MHz31ppm7K60F1E9
896-901 MHz31ppm7K60F1D9
896-901 MHz31ppm7K60F1E9
896-901 MHz31ppm11K0F3E9
901-902 MHz31ppm10K0F3E24D
901-902 MHz31ppm7K60F1D24D
901-902 MHz31ppm7K60F1E24D
935-940 MHz31ppm11K0F3E9
935-940 MHz31ppm7K60F1D9
935-940 MHz31ppm7K60F1E9
940-941 MHz31ppm10K0F3E24D
940-941 MHz31ppm7K60F1D24D
940-941 MHz31ppm7K60F1E24D
2402-2480 MHz0.007400015C
2402-2480 MHz0.006900015C

Grants

TCB Grant - Application sMggJIKQMZF1SyFHu4gcog==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 11/02/2017

Application Dated: 11/02/2017
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD98XU5
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: PCS Licensed Transmitter held to face
Notes: Digital Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  824.0 3.0 1.0  PM 16K0F3E
90 806.0  -  824.0 3.0 1.0  PM 11K0F3E
90 806.0  -  824.0 3.0 1.0  PM 7K60F1D
90 806.0  -  824.0 3.0 1.0  PM 7K60F1E
90 851.0  -  869.0 3.0 1.0  PM 16K0F3E
90 851.0  -  869.0 3.0 1.0  PM 11K0F3E
90 851.0  -  869.0 3.0 1.0  PM 7K60F1D
90 851.0  -  869.0 3.0 1.0  PM 7K60F1E
90 896.0  -  901.0 3.0 1.0  PM 11K0F3E
90 896.0  -  901.0 3.0 1.0  PM 7K60F1D
90 896.0  -  901.0 3.0 1.0  PM 7K60F1E
90 935.0  -  940.0 3.0 1.0  PM 11K0F3E
90 935.0  -  940.0 3.0 1.0  PM 7K60F1D
90 935.0  -  940.0 3.0 1.0  PM 7K60F1E
24D 901.0  -  902.0 3.0 1.0  PM 10K0F3E
24D 901.0  -  902.0 3.0 1.0  PM 7K60F1D
24D 901.0  -  902.0 3.0 1.0  PM 7K60F1E
24D 940.0  -  941.0 3.0 1.0  PM 10K0F3E
24D 940.0  -  941.0 3.0 1.0  PM 7K60F1D
24D 940.0  -  941.0 3.0 1.0  PM 7K60F1E

Power listed is manufacturer’s rated power. Power is select-able between 1 W and 3 W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the specified accessories documented in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, and simultaneous transmission exposure conditions are 1.05 W/kg, 5.35 W/kg and 5.40 W/kg, respectively.

EAS Grant - Application sMggJIKQMZF1SyFHu4gcog==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 11/02/2017

Application Dated: 11/02/2017
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD98XU5
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: PCS Licensed Transmitter held to face
Notes: Digital Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 806.0  -  824.0 3.0 1.0  PM 16K0F3E
90 806.0  -  824.0 3.0 1.0  PM 11K0F3E
90 806.0  -  824.0 3.0 1.0  PM 7K60F1D
90 806.0  -  824.0 3.0 1.0  PM 7K60F1E
90 851.0  -  869.0 3.0 1.0  PM 16K0F3E
90 851.0  -  869.0 3.0 1.0  PM 11K0F3E
90 851.0  -  869.0 3.0 1.0  PM 7K60F1D
90 851.0  -  869.0 3.0 1.0  PM 7K60F1E
90 896.0  -  901.0 3.0 1.0  PM 11K0F3E
90 896.0  -  901.0 3.0 1.0  PM 7K60F1D
90 896.0  -  901.0 3.0 1.0  PM 7K60F1E
90 935.0  -  940.0 3.0 1.0  PM 11K0F3E
90 935.0  -  940.0 3.0 1.0  PM 7K60F1D
90 935.0  -  940.0 3.0 1.0  PM 7K60F1E
24D 901.0  -  902.0 3.0 1.0  PM 10K0F3E
24D 901.0  -  902.0 3.0 1.0  PM 7K60F1D
24D 901.0  -  902.0 3.0 1.0  PM 7K60F1E
24D 940.0  -  941.0 3.0 1.0  PM 10K0F3E
24D 940.0  -  941.0 3.0 1.0  PM 7K60F1D
24D 940.0  -  941.0 3.0 1.0  PM 7K60F1E

Power listed is manufacturer’s rated power. Power is select-able between 1 W and 3 W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the specified accessories documented in this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, and simultaneous transmission exposure conditions are 1.05 W/kg, 5.35 W/kg and 5.40 W/kg, respectively.



TCB Grant - Application ki4YfVzD2hcqE5N60bFRsg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 11/02/2017

Application Dated: 11/02/2017
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD98XU5
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Digital Transmission System
Notes: Digital Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0069  

Output power listed is conducted.

EAS Grant - Application ki4YfVzD2hcqE5N60bFRsg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 11/02/2017

Application Dated: 11/02/2017
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD98XU5
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Digital Transmission System
Notes: Digital Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0069  

Output power listed is conducted.



TCB Grant - Application cdWgp6C9Vlf9lVEbwS95hw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 11/02/2017

Application Dated: 11/02/2017
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD98XU5
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Digital Portable Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0074  

Output power listed is conducted.

EAS Grant - Application cdWgp6C9Vlf9lVEbwS95hw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 11/02/2017

Application Dated: 11/02/2017
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMPD98XU5
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Digital Portable Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0074  

Output power listed is conducted.



Mail To: