FCC ID YAMPT580HF5
TETRA Digital Portable Terminal
by Hytera Communications Corporation Limited
Grantee Code: YAM Product Code: PT580HF5
Latest application date: 2014-10-07
FCC ID Device Details
| FCC ID | YAMPT580HF5 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YAM |
| Product Code | PT580HF5 |
| Applicant Business | Hytera Communications Corporation Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | TETRA Digital Portable Terminal |
| Test Firm | Bay Area Compliance Laboratory Corp. (Shenzhen) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 806-824 MHz | Class II permissive change or modification of presently authorized equipment | 2014-10-07 |
| 817-824 MHz | Original Equipment | 2012-04-27 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2014-10-07 | PDF 1.4 MB |
| User Manual | Users Manual | 2012-04-27 | PDF 2.8 MB |
| Int Photos | Internal Photos | 2014-10-07 | PDF 718 KB |
| Internal Photos | Internal Photos | 2012-04-27 | PDF 574.6 KB |
| Ext Photos | External Photos | 2014-10-07 | PDF 361.5 KB |
| External Photos | External Photos | 2012-04-27 | PDF 775.4 KB |
| FCC ID Label | ID Label/Location Info | 2014-10-07 | PDF 135.2 KB |
| ID Label Location | ID Label/Location Info | 2012-04-27 | PDF 118.2 KB |
| Setup Photos | Test Setup Photos | 2014-10-07 | PDF 153.2 KB |
| Test Setup Photos | Test Setup Photos | 2012-04-27 | PDF 588.7 KB |
| Test Report | Test Report | 2014-10-07 | PDF 1.7 MB |
| Test Report | Test Report | 2012-04-27 | PDF 3.1 MB |
| Manufacturer Attestation Letter | Attestation Statements | 2014-10-07 | PDF 65.9 KB |
| Attestation Letter | Cover Letter(s) | 2012-04-27 | PDF 47.6 KB |
| CIIPC Letter | Cover Letter(s) | 2014-10-07 | PDF 64.5 KB |
| Confidentiality Letter | Cover Letter(s) | 2014-10-07 | PDF 68.9 KB |
| POA | Cover Letter(s) | 2014-10-07 | PDF 18.6 KB |
| Confidentiality Letter | Cover Letter(s) | 2012-04-27 | PDF 41.8 KB |
| FCC Waiver Letter | Cover Letter(s) | 2012-04-27 | PDF 208.3 KB |
| SAR Report | RF Exposure Info | 2014-10-07 | PDF 1.9 MB |
| RF Exposure | RF Exposure Info | 2012-04-27 | PDF 3.2 MB |
| Block Diagram Metadata only | Block Diagram | PDF 136.7 KB | |
| Schematics Metadata only | Schematics | PDF 530.3 KB | |
| Operation Description Metadata only | Operational Description | PDF 407 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 264.5 KB |
Application Information
| Application ID | SV+6woss7ikL0mkpNmB/PQ== |
|---|---|
| Final Action Date | 2014-10-07 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0019701887 |
| Model | PT580HF5 |
| Frequency Range | 806-824 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | TETRA Digital Portable Terminal |
| Responsible Party | Tiantian Chen, Certification Engineer, tiantian.chen@hytera.com |
| Test Firm | John Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change documented in this filing. Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 2.06 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing. The highest reported SAR values across all filings are Head: 1.99 W/kg, Body-worn: 1.97 W/kg when operating at 50% duty cycle. This Certification is approved pursuant to the Tetra waiver FCC 11-63. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| SV+6woss7ikL0mkpNmB/PQ== | 2014-10-07 | Class II permissive change or modification of presently authorized equipment |
| e+FeNVnUsTJCEc1+b06rLw== | 2012-04-27 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application SV+6woss7ikL0mkpNmB/PQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 10/07/2014 Application Dated: 10/07/2014 |
| Hytera Communications Corporation Limited |
| Hytera Tower, Hi-Tech Industrial Park North, |
| 9108# Beihuan Road, Nanshan District, |
| Shenzhen, 518057 China |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPT580HF5 |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | TETRA Digital Portable Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 806.0 - 824.0 | 1.8 | 0.08 PM | 20K0DXW | |
| 90 | 851.0 - 869.0 | 1.8 | 0.07 PM | 20K0GXW |
| Class II Permissive Change documented in this filing. Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 2.06 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing. The highest reported SAR values across all filings are Head: 1.99 W/kg, Body-worn: 1.97 W/kg when operating at 50% duty cycle. This Certification is approved pursuant to the Tetra waiver FCC 11-63. |
EAS Grant - Application SV+6woss7ikL0mkpNmB/PQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Limited Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China |
Date of Grant: 10/07/2014 Application Dated: 10/07/2014 |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPT580HF5 |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | TETRA Digital Portable Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 806.0 - 824.0 | 1.8 | 0.08 PM | 20K0DXW | |
| 90 | 851.0 - 869.0 | 1.8 | 0.07 PM | 20K0GXW |
| Class II Permissive Change documented in this filing. Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 2.06 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing. The highest reported SAR values across all filings are Head: 1.99 W/kg, Body-worn: 1.97 W/kg when operating at 50% duty cycle. This Certification is approved pursuant to the Tetra waiver FCC 11-63. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
EMCCert Dr. Rasek GmbH Stoernhofer Berg 15 91364 Unterleinleiter, Germany |
Date of Grant: 04/27/2012 Application Dated: 04/27/2012 |
| Hytera Communications Corporation Ltd. |
| Hyt Tower, Hi-Tech Industrial Park North |
| Nanshan District, Shenzhen, 518057 China |
| Attention: Lei Xiong |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPT580HF5 |
| Name of Grantee: | Hytera Communications Corporation Ltd. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | TETRA Digital Portable Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 817.0 - 824.0 | 1.8 | 0.08 PM | 20K0DXW | |
| 90 | 862.0 - 869.0 | 1.8 | 0.07 PM | 20K0GXW |
| Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 2.06 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing. The highest reported SAR values are: Head: 1.99 W/kg, Body-worn: 1.97 W/kg when operating at 50% duty cycle. This Certification is approved pursuant to the Tetra waiver FCC 11-63. |
EAS Grant - Application e+FeNVnUsTJCEc1+b06rLw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Ltd. Hyt Tower, Hi-Tech Industrial Park North Nanshan District, Shenzhen, 518057 China |
Date of Grant: 04/27/2012 Application Dated: 04/27/2012 |
| Attention: Lei Xiong |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMPT580HF5 |
| Name of Grantee: | Hytera Communications Corporation Ltd. |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | TETRA Digital Portable Terminal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 817.0 - 824.0 | 1.8 | 0.08 PM | 20K0DXW | |
| 90 | 862.0 - 869.0 | 1.8 | 0.07 PM | 20K0GXW |
| Output power listed is rated conducted; measured maximum conducted output power as allowed by 47 CFR 90.205(s) is 2.06 Watts. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to the specific belt-clip and accessory configurations tested for this filing. The highest reported SAR values are: Head: 1.99 W/kg, Body-worn: 1.97 W/kg when operating at 50% duty cycle. This Certification is approved pursuant to the Tetra waiver FCC 11-63. |