FCC ID YAMRD62XU1
Digital Wall-mounted Repeater
by Hytera Communications Corporation Limited
Grantee Code: YAM Product Code: RD62XU1
Latest application date: 2014-01-22
FCC ID Device Details
| FCC ID | YAMRD62XU1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YAM |
| Product Code | RD62XU1 |
| Applicant Business | Hytera Communications Corporation Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | Digital Wall-mounted Repeater |
| Test Firm | Shenzhen Huatongwei International Insp. Co., Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 400-406 MHz | Original Equipment | 2014-01-22 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| YAMRD62XU1_User Manual | Users Manual | 2014-01-22 | PDF 580.7 KB |
| YAMRD62XU1_Internal photos of the EUT | Internal Photos | 2014-01-22 | PDF 795.3 KB |
| YAMRD62XU1_External photos of the EUT | External Photos | 2014-01-22 | PDF 402.4 KB |
| YAMRD62XU1_Product Declaration | Cover Letter(s) | 2014-01-22 | PDF 402.4 KB |
| YAMRD62XU1_Label and Label Location | ID Label/Location Info | 2014-01-22 | PDF 199.6 KB |
| YAMRD62XU1_Test Setup Photos of The EUT | Test Setup Photos | 2014-01-22 | PDF 318.7 KB |
| YAMRD62XU1_TRE1310003101 Test Report | Test Report | 2014-01-22 | PDF 4.4 MB |
| YAMRD62XU1_TRE1310003102 Test Report | RF Exposure Info | 2014-01-22 | PDF 236.2 KB |
| YAMRD62XU1_Frequency Attestation Letter | Cover Letter(s) | 2014-01-22 | PDF 35.9 KB |
| YAMRD62XU1_Authorization Letter | Cover Letter(s) | 2014-01-22 | PDF 65.5 KB |
| YAMRD62XU1_Confidential Request Letter | Cover Letter(s) | 2014-01-22 | PDF 70.4 KB |
| YAMRD62XU1_Justification Letter | Cover Letter(s) | 2014-01-22 | PDF 59.9 KB |
Application Information
| Application ID | 47za8actlqLvgFxkmRr/Qw== |
|---|---|
| Final Action Date | 2014-01-22 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0019701887 |
| Model | RD62XU1 |
| Frequency Range | 400-406 MHz |
| Equipment Class | BOS - All other signal boosters other than 20.21/90.219 |
| Device Description | Digital Wall-mounted Repeater |
| Responsible Party | Lei Xiong, rd@hytera.com |
| Agent | Wenliang Wenliang Wenliang, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, wenliang.ii@szhtw.com.cn |
| Technical Contact | Wenliang Li, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, wenliang.li@szhtw.com.cn |
| Non-Technical Contact | Vicky Li, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, Vicky@szhtw.com.cn |
| Test Firm | Moffy Yu, Shenzhen Huatongwei International Insp. Co., Ltd, moffy.yu@szhtw.com.cn |
| TCB Email | hotline@acbcert.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 47za8actlqLvgFxkmRr/Qw== | 2014-01-22 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 400-406 MHz | 25 | 1.01ppm | 7K60FXD | 9 | BG, EF |
| 400-406 MHz | 25 | 1.01ppm | 7K60FXW | 9 | BG, EF |
| 400-406 MHz | 1 | 1.01ppm | 11K0F3E | 9 | BG, EF |
| 400-406 MHz | 1 | 1.01ppm | 7K60FXD | 9 | BG, EF |
| 400-406 MHz | 1 | 1.01ppm | 7K60FXW | 9 | BG, EF |
| 406.1-470 MHz | 1 | 1.01ppm | 11K0F3E | 9 | BG, EF |
| 406.1-470 MHz | 1 | 1.01ppm | 7K60FXD | 9 | BG, EF |
| 406.1-470 MHz | 1 | 1.01ppm | 7K60FXW | 9 | BG, EF |
| 406.1-470 MHz | 25 | 1.01ppm | 11K0F3E | 9 | BG, EF |
| 406.1-470 MHz | 25 | 1.01ppm | 7K60FXD | 9 | BG, EF |
| 406.1-470 MHz | 25 | 1.01ppm | 7K60FXW | 9 | BG, EF |
Grants
TCB Grant - Application 47za8actlqLvgFxkmRr/Qw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 01/22/2014 Application Dated: 01/10/2014 |
| Hytera Communications Corporation Ltd. |
| Hyt Tower, Hi-Tech Industrial Park North |
| Nanshan District, Shenzhen, 518057 China |
| Attention: Lei Xiong |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMRD62XU1 |
| Name of Grantee: | Hytera Communications Corporation Ltd. |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | Digital Wall-mounted Repeater |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BG EF | 90 | 400.0 - 406.0 | 25.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 400.0 - 406.0 | 25.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 400.0 - 406.0 | 25.0 | 1.01 PM | 7K60FXW |
| BG EF | 90 | 406.1 - 470.0 | 25.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 406.1 - 470.0 | 25.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 406.1 - 470.0 | 25.0 | 1.01 PM | 7K60FXW |
| BG EF | 90 | 400.0 - 406.0 | 1.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 400.0 - 406.0 | 1.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 400.0 - 406.0 | 1.0 | 1.01 PM | 7K60FXW |
| BG EF | 90 | 406.1 - 470.0 | 1.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 406.1 - 470.0 | 1.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 406.1 - 470.0 | 1.0 | 1.01 PM | 7K60FXW |
| Power output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing. |
| BG: | The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
EAS Grant - Application 47za8actlqLvgFxkmRr/Qw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Ltd. Hyt Tower, Hi-Tech Industrial Park North Nanshan District, Shenzhen, 518057 China |
Date of Grant: 01/22/2014 Application Dated: 01/10/2014 |
| Attention: Lei Xiong |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMRD62XU1 |
| Name of Grantee: | Hytera Communications Corporation Ltd. |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | Digital Wall-mounted Repeater |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BG EF | 90 | 400.0 - 406.0 | 25.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 400.0 - 406.0 | 25.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 400.0 - 406.0 | 25.0 | 1.01 PM | 7K60FXW |
| BG EF | 90 | 406.1 - 470.0 | 25.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 406.1 - 470.0 | 25.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 406.1 - 470.0 | 25.0 | 1.01 PM | 7K60FXW |
| BG EF | 90 | 400.0 - 406.0 | 1.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 400.0 - 406.0 | 1.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 400.0 - 406.0 | 1.0 | 1.01 PM | 7K60FXW |
| BG EF | 90 | 406.1 - 470.0 | 1.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 406.1 - 470.0 | 1.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 406.1 - 470.0 | 1.0 | 1.01 PM | 7K60FXW |
| Power output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing. |
| BG: | The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| Mail To: |