FCC ID YAMRD62XVHF
Digital Wall-mounted Repeater
by Hytera Communications Corporation Limited
Grantee Code: YAM Product Code: RD62XVHF
Latest application date: 2014-03-12
FCC ID Device Details
| FCC ID | YAMRD62XVHF |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YAM |
| Product Code | RD62XVHF |
| Applicant Business | Hytera Communications Corporation Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | Digital Wall-mounted Repeater |
| Test Firm | Shenzhen Huatongwei International Insp. Co., Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 136-174 MHz | Original Equipment | 2014-03-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| YAMRD62XVHF_User Manual | Users Manual | 2014-03-12 | PDF 580.7 KB |
| YAMRD62XVHF_Internal photos of the EUT | Internal Photos | 2014-03-12 | PDF 3.4 MB |
| YAMRD62XVHF_External photos of the EUT | External Photos | 2014-03-12 | PDF 402.4 KB |
| YAMRD62XVHF_Label and Label Location-Rev0 | ID Label/Location Info | 2014-03-12 | PDF 196 KB |
| YAMRD62XVHF_Test Setup Photos of The EUT | Test Setup Photos | 2014-03-12 | PDF 318.7 KB |
| YAMRD62XVHF_TRE1312008201 Test Report | Test Report | 2014-03-12 | PDF 3.8 MB |
| YAMRD62XVHF_TRE1312008202 Test Report | RF Exposure Info | 2014-03-12 | PDF 801.1 KB |
| YAMRD62XVHF_Frequency Attestation Letter | Cover Letter(s) | 2014-03-12 | PDF 38.3 KB |
| YAMRD62XVHF_Authorization Letter | Cover Letter(s) | 2014-03-12 | PDF 61.6 KB |
| YAMRD62XVHF_Confidential Request Letter | Cover Letter(s) | 2014-03-12 | PDF 66.5 KB |
| YAMRD62XVHF_Justification Letter | Cover Letter(s) | 2014-03-12 | PDF 55.6 KB |
| YAMRD62XVHF_Product Declaration | Cover Letter(s) | 2014-03-12 | PDF 53.7 KB |
| Confidential_YAMRD62XVHF_Block Diagram Metadata only | Block Diagram | PDF 142.5 KB | |
| Confidential_YAMRD62XVHF_Schematic Metadata only | Schematics | PDF 801.1 KB | |
| Confidential_YAMRD62XVHF_Operation Description Metadata only | Operational Description | PDF 207.7 KB | |
| YAMRD62XVHF_Part List Metadata only | Parts List/Tune Up Info | PDF 102.9 KB | |
| YAMRD62XVHF_Tune up Tolerance Metadata only | Parts List/Tune Up Info | PDF 178.8 KB |
Application Information
| Application ID | BU0qv+yWkKZJTn3JJgt2fw== |
|---|---|
| Final Action Date | 2014-03-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0019701887 |
| Model | RD62XVHF |
| Frequency Range | 136-174 MHz |
| Equipment Class | BOS - All other signal boosters other than 20.21/90.219 |
| Device Description | Digital Wall-mounted Repeater |
| Responsible Party | Tiantian Chen, Certification Engineer, tiantian.chen@hytera.com |
| Agent | Wenliang Wenliang Wenliang, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, wenliang.ii@szhtw.com.cn |
| Technical Contact | Wenliang Li, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, wenliang.li@szhtw.com.cn |
| Non-Technical Contact | Vicky Li, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, Vicky@szhtw.com.cn |
| Test Firm | Moffy Yu, Shenzhen Huatongwei International Insp. Co., Ltd, moffy.yu@szhtw.com.cn |
| TCB Email | hotline@acbcert.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| BU0qv+yWkKZJTn3JJgt2fw== | 2014-03-12 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application BU0qv+yWkKZJTn3JJgt2fw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 03/12/2014 Application Dated: 02/25/2014 |
| Hytera Communications Corporation Limited |
| Hytera Tower, Hi-Tech Industrial Park North, |
| 9108# Beihuan Road, Nanshan District, |
| Shenzhen, 518057 China |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMRD62XVHF |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | Digital Wall-mounted Repeater |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BG EF | 90 | 136.0 - 174.0 | 25.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 136.0 - 174.0 | 25.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 136.0 - 174.0 | 25.0 | 1.01 PM | 7K60FXW |
| BG EF | 90 | 136.0 - 174.0 | 1.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 136.0 - 174.0 | 1.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 136.0 - 174.0 | 1.0 | 1.01 PM | 7K60FXW |
| Power output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing. |
| BG: | The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
EAS Grant - Application BU0qv+yWkKZJTn3JJgt2fw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Limited Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District, Shenzhen, 518057 China |
Date of Grant: 03/12/2014 Application Dated: 02/25/2014 |
| Attention: Tiantian Chen , Certification Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMRD62XVHF |
| Name of Grantee: | Hytera Communications Corporation Limited |
| Equipment Class: | All other signal boosters other than 20.21/90.219 |
| Notes: | Digital Wall-mounted Repeater |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BG EF | 90 | 136.0 - 174.0 | 25.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 136.0 - 174.0 | 25.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 136.0 - 174.0 | 25.0 | 1.01 PM | 7K60FXW |
| BG EF | 90 | 136.0 - 174.0 | 1.0 | 1.01 PM | 11K0F3E |
| BG EF | 90 | 136.0 - 174.0 | 1.0 | 1.01 PM | 7K60FXD |
| BG EF | 90 | 136.0 - 174.0 | 1.0 | 1.01 PM | 7K60FXW |
| Power output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing. |
| BG: | The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed. |
| EF: | This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization. |
| Mail To: |