FCC ID YAMRD62XVHF

Digital Wall-mounted Repeater

by Hytera Communications Corporation Limited

Grantee Code: YAM   Product Code: RD62XVHF
Latest application date: 2014-03-12

FCC ID Device Details

FCC IDYAMRD62XVHF
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYAM
Product CodeRD62XVHF
Applicant BusinessHytera Communications Corporation Limited 🇨🇳
Related Domains hytera.com szhtw.com.cn
Equipment ClassDigital Wall-mounted Repeater
Test FirmShenzhen Huatongwei International Insp. Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
136-174 MHzOriginal Equipment2014-03-12

Exhibits

DocumentTypeAvailableFile
YAMRD62XVHF_User ManualUsers Manual2014-03-12PDF 580.7 KB
YAMRD62XVHF_Internal photos of the EUTInternal Photos2014-03-12PDF 3.4 MB
YAMRD62XVHF_External photos of the EUTExternal Photos2014-03-12PDF 402.4 KB
YAMRD62XVHF_Label and Label Location-Rev0ID Label/Location Info2014-03-12PDF 196 KB
YAMRD62XVHF_Test Setup Photos of The EUTTest Setup Photos2014-03-12PDF 318.7 KB
YAMRD62XVHF_TRE1312008201 Test ReportTest Report2014-03-12PDF 3.8 MB
YAMRD62XVHF_TRE1312008202 Test ReportRF Exposure Info2014-03-12PDF 801.1 KB
YAMRD62XVHF_Frequency Attestation LetterCover Letter(s)2014-03-12PDF 38.3 KB
YAMRD62XVHF_Authorization LetterCover Letter(s)2014-03-12PDF 61.6 KB
YAMRD62XVHF_Confidential Request LetterCover Letter(s)2014-03-12PDF 66.5 KB
YAMRD62XVHF_Justification LetterCover Letter(s)2014-03-12PDF 55.6 KB
YAMRD62XVHF_Product DeclarationCover Letter(s)2014-03-12PDF 53.7 KB
Confidential_YAMRD62XVHF_Block Diagram Metadata onlyBlock DiagramPDF 142.5 KB
Confidential_YAMRD62XVHF_Schematic Metadata onlySchematicsPDF 801.1 KB
Confidential_YAMRD62XVHF_Operation Description Metadata onlyOperational DescriptionPDF 207.7 KB
YAMRD62XVHF_Part List Metadata onlyParts List/Tune Up InfoPDF 102.9 KB
YAMRD62XVHF_Tune up Tolerance Metadata onlyParts List/Tune Up InfoPDF 178.8 KB

Application Information

Application IDBU0qv+yWkKZJTn3JJgt2fw==
Final Action Date2014-03-12
Application PurposeOriginal Equipment
Applicant FRN0019701887
ModelRD62XVHF
Frequency Range136-174 MHz
Equipment ClassBOS - All other signal boosters other than 20.21/90.219
Device DescriptionDigital Wall-mounted Repeater
Responsible PartyTiantian Chen, Certification Engineer, tiantian.chen@hytera.com , +86-755-26972999
AgentWenliang Wenliang Wenliang, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, wenliang.ii@szhtw.com.cn , 86-755-26715538
Technical ContactWenliang Li, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, wenliang.li@szhtw.com.cn , 86-755-26715538
Non-Technical ContactVicky Li, Shenzhen Huatongwei Intermation Inspection Co,.Ltd, Vicky@szhtw.com.cn , 86-755-26715386
Test FirmMoffy Yu, Shenzhen Huatongwei International Insp. Co., Ltd, moffy.yu@szhtw.com.cn , 86-755-26748078
TCB Emailhotline@acbcert.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing.

Applications

Application IDDatePurpose
BU0qv+yWkKZJTn3JJgt2fw==2014-03-12Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
136-174 MHz251.01ppm11K0F3E9BG, EF
136-174 MHz251.01ppm7K60FXD9BG, EF
136-174 MHz251.01ppm7K60FXW9BG, EF
136-174 MHz11.01ppm11K0F3E9BG, EF
136-174 MHz11.01ppm7K60FXD9BG, EF
136-174 MHz11.01ppm7K60FXW9BG, EF

Grants

TCB Grant - Application BU0qv+yWkKZJTn3JJgt2fw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  ACB, Inc.
6731 Whittier Avenue Suite C110
McLean, VA 22101
Date of Grant: 03/12/2014

Application Dated: 02/25/2014
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMRD62XVHF
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: All other signal boosters other than 20.21/90.219
Notes: Digital Wall-mounted Repeater
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BG EF 90 136.0  -  174.0 25.0 1.01  PM 11K0F3E
BG EF 90 136.0  -  174.0 25.0 1.01  PM 7K60FXD
BG EF 90 136.0  -  174.0 25.0 1.01  PM 7K60FXW
BG EF 90 136.0  -  174.0 1.0 1.01  PM 11K0F3E
BG EF 90 136.0  -  174.0 1.0 1.01  PM 7K60FXD
BG EF 90 136.0  -  174.0 1.0 1.01  PM 7K60FXW

Power output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing.

BG: The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application BU0qv+yWkKZJTn3JJgt2fw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 03/12/2014

Application Dated: 02/25/2014
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMRD62XVHF
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: All other signal boosters other than 20.21/90.219
Notes: Digital Wall-mounted Repeater
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BG EF 90 136.0  -  174.0 25.0 1.01  PM 11K0F3E
BG EF 90 136.0  -  174.0 25.0 1.01  PM 7K60FXD
BG EF 90 136.0  -  174.0 25.0 1.01  PM 7K60FXW
BG EF 90 136.0  -  174.0 1.0 1.01  PM 11K0F3E
BG EF 90 136.0  -  174.0 1.0 1.01  PM 7K60FXD
BG EF 90 136.0  -  174.0 1.0 1.01  PM 7K60FXW

Power output is conducted. RF power is switchable from 1W to rated power 25W. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration, and the exposure conditions and/or duration of their passengers and bystanders, to comply with the General Population/Uncontrolled MPE limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Users must be provided with the training information, antenna installation and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must be installed as indicated in this filing.


BG: The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed.
EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

Mail To: