FCC ID YAMTF-312

FRS/GMRS TWO-WAY RADIOS

by Hytera Communications Corporation Limited

Grantee Code: YAM   Product Code: TF312
Latest application date: 2017-06-01

FCC ID Device Details

FCC IDYAMTF-312
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYAM
Product CodeTF312
Applicant BusinessHytera Communications Corporation Limited 🇨🇳
Related Domains hytera.com
Equipment ClassFRS/GMRS TWO-WAY RADIOS
Test FirmBay Area Compliance Laboratories Corp.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
462.55-462.725 MHzOriginal Equipment2017-06-01

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2017-06-01PDF 191.8 KB
Int PhotosInternal Photos2017-06-01PDF 502.9 KB
Ext PhotosExternal Photos2017-06-01PDF 323.1 KB
FCC ID LabelID Label/Location Info2017-06-01PDF 145 KB
Setup PhotosTest Setup Photos2017-06-01PDF 115.4 KB
Test ReportTest Report2017-06-01PDF 320 KB
Confidentiality LetterCover Letter(s)2017-06-01PDF 72.6 KB
POACover Letter(s)2017-06-01PDF 18.7 KB
SAR Probe & Dipole Cal CertRF Exposure Info2017-06-01PDF 3.1 MB
SAR ReportRF Exposure Info2017-06-01PDF 664.9 KB
SAR Scan PoltsRF Exposure Info2017-06-01PDF 166.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 59 KB
Schemtics Metadata onlySchematicsPDF 86 KB
Operation Description Metadata onlyOperational DescriptionPDF 92.5 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 46.8 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 166.5 KB

Application Information

Application IDxbxCNtOPe/kDqXyNa+xtJg==
Final Action Date2017-06-01
Application PurposeOriginal Equipment
Applicant FRN0019701887
ModelTF-312
Frequency Range462.55-462.725 MHz
Equipment ClassFRF - Part 95 Family Radio Face Held Transmitter
Device DescriptionFRS/GMRS TWO-WAY RADIOS
Responsible PartyTiantian Chen, Certification Engineer, tiantian.chen@hytera.com , +86-755-26972999
Test FirmJohn Chan, Bay Area Compliance Laboratories Corp., john.chan@baclcorp.com , 86-28-65525123
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP. This device is authorized to operate in the following radio services: FRS (Part 95B) or GMRS (Part 95A). There must be an informational insert inside the box (product package) or the user’s manual must include information that clearly informs the consumer (buyer/owner) when the radio is transmitting on GMRS frequencies, that operation on GMRS frequencies requires an FCC license and such operation is subject to additional rules specified in 47 C.F.R. Part 95. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific antennas, belt-clips, holsters and accessories tested for this device. Users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported 50% duty cycle SAR levels for head and body-worn accessories exposure conditions are 0.13 W/kg and 0.20 W/kg respectively.

Applications

Application IDDatePurpose
xbxCNtOPe/kDqXyNa+xtJg==2017-06-01Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
462.55-462.725 MHz0.1262.5ppm5K91F3E95A
462.563-462.713 MHz0.1212.5ppm5K91F3E95B
467.563-467.713 MHz0.1212.5ppm5K91F3E95B

Grants

TCB Grant - Application xbxCNtOPe/kDqXyNa+xtJg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 06/01/2017

Application Dated: 06/01/2017
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMTF-312
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Part 95 Family Radio Face Held Transmitter
Notes: FRS/GMRS TWO-WAY RADIOS
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95A 462.55  -  462.725 0.126 2.5  PM 5K91F3E
95B 462.5625  -  462.7125 0.121 2.5  PM 5K91F3E
95B 467.5625  -  467.7125 0.121 2.5  PM 5K91F3E

Output power listed is ERP. This device is authorized to operate in the following radio services: FRS (Part 95B) or GMRS (Part 95A). There must be an informational insert inside the box (product package) or the user’s manual must include information that clearly informs the consumer (buyer/owner) when the radio is transmitting on GMRS frequencies, that operation on GMRS frequencies requires an FCC license and such operation is subject to additional rules specified in 47 C.F.R. Part 95. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific antennas, belt-clips, holsters and accessories tested for this device. Users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported 50% duty cycle SAR levels for head and body-worn accessories exposure conditions are 0.13 W/kg and 0.20 W/kg respectively.

EAS Grant - Application xbxCNtOPe/kDqXyNa+xtJg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 06/01/2017

Application Dated: 06/01/2017
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMTF-312
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Part 95 Family Radio Face Held Transmitter
Notes: FRS/GMRS TWO-WAY RADIOS
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
95A 462.55  -  462.725 0.126 2.5  PM 5K91F3E
95B 462.5625  -  462.7125 0.121 2.5  PM 5K91F3E
95B 467.5625  -  467.7125 0.121 2.5  PM 5K91F3E

Output power listed is ERP. This device is authorized to operate in the following radio services: FRS (Part 95B) or GMRS (Part 95A). There must be an informational insert inside the box (product package) or the user’s manual must include information that clearly informs the consumer (buyer/owner) when the radio is transmitting on GMRS frequencies, that operation on GMRS frequencies requires an FCC license and such operation is subject to additional rules specified in 47 C.F.R. Part 95. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific antennas, belt-clips, holsters and accessories tested for this device. Users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest reported 50% duty cycle SAR levels for head and body-worn accessories exposure conditions are 0.13 W/kg and 0.20 W/kg respectively.



Mail To: