FCC ID YAMTM-610U2

Mobile Radio

by Hytera Communications Corporation Limited

Grantee Code: YAM   Product Code: TM610U2
Latest application date: 2010-08-13

FCC ID Device Details

FCC IDYAMTM-610U2
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYAM
Product CodeTM610U2
Applicant BusinessHytera Communications Corporation Limited 🇨🇳
Related Domains hytera.com
Equipment ClassMobile Radio
Test FirmBay Area Compliance Laboratory Corp. (Shenzhen)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-500 MHzChange in identification of presently authorized equipment. Original FCC ID: R74TM-610U2 Grant Date: 01/05/20072010-08-13

Exhibits

DocumentTypeAvailableFile
External PhotosExternal Photos2010-08-13PDF 145.9 KB
FCC ID LabelID Label/Location Info2010-08-13PDF 307.9 KB
Change ID RequestCover Letter(s)2010-08-13PDF 230.8 KB
Letter from Original HolderCover Letter(s)2010-08-13PDF 19.6 KB

Application Information

Application IDm0KdFRMQB5/S7fz409Yfgg==
Final Action Date2010-08-13
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: R74TM-610U2 Grant Date: 01/05/2007
Applicant FRN0019701887
ModelTM-610U2
Frequency Range450-500 MHz
Equipment ClassTNB - Licensed Non-Broadcast Station Transmitter
Device DescriptionMobile Radio
Responsible PartyLei Xiong, rd@hytera.com , +86-755-2697-2999
Test FirmJohn Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com , 08675533320018
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is peak conducted. The antennas used for this transmitter must be vehicle-mounted as described in this filing. The maximum antenna gain must not exceed 3 dBi. This radio must operate in push-to-talk mode with a duty factor not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.

Applications

Application IDDatePurpose
m0KdFRMQB5/S7fz409Yfgg==2010-08-13Change in identification of presently authorized equipment. Original FCC ID: R74TM-610U2 Grant Date: 01/05/2007

Equipment Authorization

FrequencyOutputToleranceEmissionRules
450-500 MHz251.9ppm11K0F3E9
450-500 MHz251.9ppm16K0F3E9

Grants

TCB Grant - Application m0KdFRMQB5/S7fz409Yfgg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 08/13/2010

Application Dated: 08/13/2010
Hytera Communications Corporation Ltd.
Hyt Tower, Hi-Tech Industrial Park North
Nanshan District, Shenzhen, 518057
China
 
Attention: Lei Xiong

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMTM-610U2
Name of Grantee:  Hytera Communications Corporation Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Mobile Radio
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  500.0 25.0 1.9  PM 11K0F3E
90 450.0  -  500.0 25.0 1.9  PM 16K0F3E

Output power is peak conducted. The antennas used for this transmitter must be vehicle-mounted as described in this filing. The maximum antenna gain must not exceed 3 dBi. This radio must operate in push-to-talk mode with a duty factor not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.

EAS Grant - Application m0KdFRMQB5/S7fz409Yfgg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Ltd.
Hyt Tower, Hi-Tech Industrial Park North
Nanshan District, Shenzhen, 518057
China
  Date of Grant: 08/13/2010

Application Dated: 08/13/2010
 
Attention: Lei Xiong

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMTM-610U2
Name of Grantee:  Hytera Communications Corporation Ltd.
Equipment Class: Licensed Non-Broadcast Station Transmitter
Notes: Mobile Radio
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 450.0  -  500.0 25.0 1.9  PM 11K0F3E
90 450.0  -  500.0 25.0 1.9  PM 16K0F3E

Output power is peak conducted. The antennas used for this transmitter must be vehicle-mounted as described in this filing. The maximum antenna gain must not exceed 3 dBi. This radio must operate in push-to-talk mode with a duty factor not exceeding 50% and must be restricted to work related operations in an Occupational/Controlled RF exposure Environment. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled exposure limit and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit.