| FCC ID | YAMTR-50V |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YAM |
| Product Code | TR50V |
| Applicant Business | Hytera Communications Corporation Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | Portable Repeater/Transceiver |
| Test Firm | Bay Area Compliance Laboratory Corp. (Shenzhen) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 136-174 MHz | Change in identification of presently authorized equipment. Original FCC ID: R74TR-50V Grant Date: 06/28/2006 | 2010-09-13 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2010-09-13 | PDF 381.5 KB |
| FCC ID Label | ID Label/Location Info | 2010-09-13 | PDF 94.5 KB |
| Change ID Request Letter | Cover Letter(s) | 2010-09-13 | PDF 230.8 KB |
| Permission from the Original Holder | Cover Letter(s) | 2010-09-13 | PDF 19.7 KB |
Application Information
| Application ID | MZluY3uELjCG8SPr5h46ew== |
|---|---|
| Final Action Date | 2010-09-13 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: R74TR-50V Grant Date: 06/28/2006 |
| Applicant FRN | 0019701887 |
| Model | TR-50V |
| Frequency Range | 136-174 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | Portable Repeater/Transceiver |
| Responsible Party | Lei Xiong, rd@hytera.com |
| Test Firm | John Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95 & 97 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment, not exceeding a maximum transmitting duty cycle factor of 50%. MPE evaluation covers fixed and mobile applications for use with a 2 dBi antenna. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled exposure limits and requirements and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit. The antenna must be installed to provide a separation distance of at least 60 cm from all persons during use with a duty factor not exceeding 50%. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| MZluY3uELjCG8SPr5h46ew== | 2010-09-13 | Change in identification of presently authorized equipment. Original FCC ID: R74TR-50V Grant Date: 06/28/2006 |
Equipment Authorization
Grants
TCB Grant - Application MZluY3uELjCG8SPr5h46ew==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 09/13/2010 Application Dated: 09/13/2010 |
| Hytera Communications Corporation Ltd. |
| Hyt Tower, Hi-Tech Industrial Park North |
| Nanshan District, Shenzhen, 518057 China |
| Attention: Lei Xiong |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMTR-50V |
| Name of Grantee: | Hytera Communications Corporation Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Portable Repeater/Transceiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 136.0 - 174.0 | 5.0 | 1.4 PM | 11K0F3E | |
| 90 | 136.0 - 174.0 | 5.0 | 1.2 PM | 16K0F3E |
| Power output listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment, not exceeding a maximum transmitting duty cycle factor of 50%. MPE evaluation covers fixed and mobile applications for use with a 2 dBi antenna. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled exposure limits and requirements and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit. The antenna must be installed to provide a separation distance of at least 60 cm from all persons during use with a duty factor not exceeding 50%. |
EAS Grant - Application MZluY3uELjCG8SPr5h46ew==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hytera Communications Corporation Ltd. Hyt Tower, Hi-Tech Industrial Park North Nanshan District, Shenzhen, 518057 China |
Date of Grant: 09/13/2010 Application Dated: 09/13/2010 |
| Attention: Lei Xiong |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YAMTR-50V |
| Name of Grantee: | Hytera Communications Corporation Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | Portable Repeater/Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 90 | 136.0 - 174.0 | 5.0 | 1.4 PM | 11K0F3E | |
| 90 | 136.0 - 174.0 | 5.0 | 1.2 PM | 16K0F3E |
| Power output listed is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure environment, not exceeding a maximum transmitting duty cycle factor of 50%. MPE evaluation covers fixed and mobile applications for use with a 2 dBi antenna. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled exposure limits and requirements and also have control of the exposure conditions of bystanders for complying with General Population/Uncontrolled exposure limit. The antenna must be installed to provide a separation distance of at least 60 cm from all persons during use with a duty factor not exceeding 50%. |
| Mail To: |